Hydrodynamic effects of compliance mismatch in stented arteries.

Cardiovascular diseases are the number one cause of death in the world, making the understanding of hemodynamics and development of treatment options imperative. The most common modality for treatment of occlusive coronary artery diseases is the use of stents. Stent design profoundly influences the postprocedural hemodynamic and solid mechanical environment of the stented artery. However, despite their wide acceptance, the incidence of stent late restenosis is still high (Zwart et al., 2010, "Coronary Stent Thrombosis in the Current Era: Challenges and Opportunities for Treatment," Current Treatment Options in Cardiovascular Medicine, 12(1), pp. 46-57), and it is most prevailing at the proximal and distal ends of the stent. In this work, we focus our investigation on the localized hemodynamic effects of compliance mismatch due to the presence of a stent in an artery. The compliance mismatch in a stented artery is maximized at the proximal and distal ends of the stent. Hence, it is our objective to understand and reveal the mechanism by which changes in compliance contribute to the generation of nonphysiological wall shear stress (WSS). Such adverse hemodynamic conditions could have an effect on the onset of restenosis. Three-dimensional, spatiotemporally resolved computational fluid dynamics simulations of pulsatile flow with fluid-structure interaction were carried out for a simplified coronary artery with physiologically relevant flow parameters. A model with uniform elastic modulus is used as the baseline control case. In order to study the effect of compliance variation on local hemodynamics, this baseline model is compared with models where the elastic modulus was increased by two-, five-, and tenfold in the middle of the vessel. The simulations provided detailed information regarding the recirculation zone dynamics formed during flow reversals. The results suggest that discontinuities in compliance cause critical changes in local hemodynamics, namely, altering the local pressure and velocity gradients. The change in pressure gradient at the discontinuity was as high as 90%. The corresponding changes in WSS and oscillatory shear index calculated were 9% and 15%, respectively. We demonstrate that these changes are attributed to the physical mechanism associating the pressure gradient discontinuities to the production of vorticity (vorticity flux) due to the presence of the stent. The pressure gradient discontinuities and augmented vorticity flux are affecting the wall shear stresses. As a result, this work reveals how compliance variations act to modify the near wall hemodynamics of stented arteries.

[1]  M. Dauzat,et al.  Wall Mechanics of the Stented Rabbit Aorta: Long-Term Study and Correlation with Histological Findings , 2003, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[2]  C. Hartley,et al.  Blood flow through axially symmetric sections of compliant vessels: new effective closed models , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Pavlos P. Vlachos,et al.  A Scaling Parameter for Predicting Pressure Wave Reflection in Stented Arteries , 2009 .

[4]  C Kleinstreuer,et al.  Numerical investigation and prediction of atherogenic sites in branching arteries. , 1995, Journal of biomechanical engineering.

[5]  Satya Karri Laminar and Transitional Flow disturbances in Diseased and Stented Arteries , 2009 .

[6]  Louis Rosenhead,et al.  Laminar boundary layers , 1963 .

[7]  G L'Italien,et al.  Effect of compliance mismatch on vascular graft patency. , 1987, Journal of vascular surgery.

[8]  Joel L. Berry,et al.  Experimental and Computational Flow Evaluation of Coronary Stents , 2000, Annals of Biomedical Engineering.

[9]  Suncica Canic,et al.  Self-Consistent Effective Equations Modeling Blood Flow in Medium-to-Large Compliant Arteries , 2005, Multiscale Model. Simul..

[10]  A. Wahle,et al.  Effect of Endothelial Shear Stress on the Progression of Coronary Artery Disease, Vascular Remodeling, and In-Stent Restenosis in Humans: In Vivo 6-Month Follow-Up Study , 2003, Circulation.

[11]  D. L. Fry Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients , 1968, Circulation research.

[12]  W. Abbott,et al.  PULSATILE BLOOD-FLOW IN ARTERIAL GRAFTS , 1976, The Lancet.

[13]  Pavlos Vlachos,et al.  In Vitro Comparison of the Effect of Stent Configuration on Wall Shear Stress Using Time-resolved Particle Image Velocimetry , 2010, Annals of Biomedical Engineering.

[14]  S. Čanić,et al.  Mathematical analysis of the quasilinear effects in a hyperbolic model blood flow through compliant axi‐symmetric vessels , 2003 .

[15]  T. Togawa,et al.  Adaptive regulation of wall shear stress optimizing vascular tree function. , 1984, Bulletin of mathematical biology.

[16]  Danesh K. Tafti,et al.  A parallel boundary fitted dynamic mesh solver for applications to flapping flight , 2009 .

[17]  A. Kastrati,et al.  Intracoronary Stenting and Angiographic Results: Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial , 2001, Circulation.

[18]  Suncica Canic,et al.  Fluid-structure interaction in a pre-stressed tube with thick elastic walls I: the stationary Stokes problem , 2007, Networks Heterog. Media.

[19]  S Glagov,et al.  The role of fluid mechanics in the localization and detection of atherosclerosis. , 1993, Journal of biomechanical engineering.

[20]  T. Tezduyar,et al.  Arterial fluid mechanics modeling with the stabilized space–time fluid–structure interaction technique , 2008 .

[21]  A Rachev,et al.  A model of stress-induced geometrical remodeling of vessel segments adjacent to stents and artery/graft anastomoses. , 2000, Journal of theoretical biology.

[22]  Danesh K. Tafti,et al.  Time-accurate Techniques For Turbulent HeatTransfer Analysis In Complex Geometries , 2010 .

[23]  J. LaDisa,et al.  Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation , 2003, Annals of Biomedical Engineering.

[24]  P. Pagel,et al.  Stent Implantation Alters Coronary Artery Hemodynamics and Wall Shear Stress During Maximal Vasodilation. , 2002, Journal of applied physiology.

[25]  G Moulin,et al.  Hemodynamics and wall mechanics after stent placement in swine iliac arteries: comparative results from six stent designs. , 1999, Radiology.

[26]  C. Ross Ethier,et al.  Human Saphenous Vein Coronary Artery Bypass Graft Morphology, Geometry and Hemodynamics , 2005, Annals of Biomedical Engineering.

[27]  Giovanna Guidoboni,et al.  Blood Flow in Compliant Arteries: An Effective Viscoelastic Reduced Model, Numerics, and Experimental Validation , 2006, Annals of Biomedical Engineering.

[28]  Pavlos Vlachos,et al.  In Vitro, Time-Resolved PIV Comparison of the Effect of Stent Design on Wall Shear Stress , 2009, Annals of Biomedical Engineering.

[29]  D. Kass,et al.  Novel regulation of cardiac force‐frequency relation by CREM (cAMP response element modulator) , 2003, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[30]  Y. Fung,et al.  Basic Hemodynamics and Its Role in Disease Processes , 1980 .

[31]  T Togawa,et al.  Adaptive regulation of wall shear stress to flow change in the canine carotid artery. , 1980, The American journal of physiology.

[32]  M. Olufsen,et al.  Numerical Simulation and Experimental Validation of Blood Flow in Arteries with Structured-Tree Outflow Conditions , 2000, Annals of Biomedical Engineering.

[33]  D. Ku,et al.  Pulsatile flow in the human left coronary artery bifurcation: average conditions. , 1996, Journal of biomechanical engineering.

[34]  J. Womersley,et al.  An Elastic Tube Theory of Pulse Transmission and Oscillatory Flow in Mammalian Arteries , 1957 .

[35]  Suncica Canic,et al.  Effective Equations Modeling the Flow of a Viscous Incompressible Fluid through a Long Elastic Tube Arising in the Study of Blood Flow through Small Arteries , 2003, SIAM J. Appl. Dyn. Syst..

[36]  John F LaDisa,et al.  Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries. , 2005, American journal of physiology. Heart and circulatory physiology.

[37]  S. Yazdani,et al.  DPIV measurements of flow disturbances in stented artery models: adverse affects of compliance mismatch. , 2004, Journal of biomechanical engineering.

[38]  M. Ojha Wall shear stress temporal gradient and anastomotic intimal hyperplasia. , 1994, Circulation research.