An FPGA-based frequency response analyzer for multisine and stepped sine measurements on stationary and time-varying impedance

We report the development of a field programmable gate array (FPGA) based frequency response analyzer (FRA) for impedance frequency response function (FRF) measurements using periodic excitations, i.e. sine waves and multisines. The stepped sine measurement uses two dedicated hardware-built digital embedded multiplier blocks to extract the phase and quadrature components of the output signal. The multisine FRF measurements compute the fast Fourier transform (FFT) of the input/output signals. In this paper, we describe its design, implementation and performance evaluation, performing electrical impedance spectroscopy (EIS) measurements on phantoms. The stepped sine accuracy is 1.21% at 1 kΩ (1%), the precision is 35 mΩ and the total harmonic distortion plus noise (THD+N) is −120 dB. As for the multisine impedance FRF measurements, the magnitude and phase precision are, respectively, 0.23 Ω at 48.828 kHz and 0.021 deg at 8.087 MHz when measuring a resistor 505 Ω (1%). The magnitude accuracy is 0.55% at 8.087 MHz while the phase accuracy is 0.17 deg at 6.54 MHz. In all, the stepped sine signal-to-noise ratio (SNR) is 84 dB and 65 dB at frequencies below and above 1 MHz respectively. The SNR for the multisine FRF measurements is above 65 dB (30 kHz–10 MHz). The FRA bandwidth is 610.4 mHz–12.5 MHz and the maximum FRF measurement rate exciting with multisines starting at 30 kHz is 200 spectra s−1. Based on its technical specifications and versatility, the FRA presented can be used in many applications, e.g. for getting insight quickly into the instantaneous impedance FRF of the time-varying impedance under test.

[1]  C. Davis,et al.  Impedance spectroscopy of human erythrocytes: system calibration, and nonlinear modeling , 1993, IEEE Transactions on Biomedical Engineering.

[2]  R Bragós,et al.  A wide-band AC-coupled current source for electrical impedance tomography. , 1994, Physiological measurement.

[3]  Zonghai Gao,et al.  Design of a wideband excitation source for fast bioimpedance spectroscopy , 2010 .

[4]  Gerd Vandersteen,et al.  Novel Estimation of the Electrical Bioimpedance Using the Local Polynomial Method. Application to In Vivo Real-Time Myocardium Tissue Impedance Characterization During the Cardiac Cycle , 2011, IEEE Transactions on Biomedical Engineering.

[5]  L. A. Geddes,et al.  The impedance of stainless-steel electrodes , 1971, Medical and biological engineering.

[6]  D. Jeong,et al.  Emerging memories: resistive switching mechanisms and current status , 2012, Reports on progress in physics. Physical Society.

[7]  Gary J Saulnier,et al.  A high-precision voltage source for EIT. , 2006, Physiological measurement.

[8]  R Bragos,et al.  Harmonic impedance spectra identification from time-varying bioimpedance: theory and validation , 2013, Physiological measurement.

[9]  Andreas Demosthenous,et al.  Comparison of a new integrated current source with the modified Howland circuit for EIT applications , 2009, Physiological measurement.

[10]  Roland Zengerle,et al.  Online Tissue Discrimination for Transcutaneous Needle Guidance Applications Using Broadband Impedance Spectroscopy , 2012, IEEE Transactions on Biomedical Engineering.

[11]  F J Lidgey,et al.  Development of a real-time adaptive current tomograph. , 1994, Physiological measurement.

[12]  C Margo,et al.  A four-electrode low frequency impedance spectroscopy measurement system using the AD5933 measurement chip , 2013, Physiological measurement.

[13]  Xinjian Huang,et al.  A fast and simple electrochemical impedance spectroscopy measurement technique and its application in portable, low-cost instrument for impedimetric biosensing , 2011 .

[14]  James J. Ackmann,et al.  Complex bioelectric impedance measurement system for the frequency range from 5 Hz to 1 MHz , 1993, Annals of Biomedical Engineering.

[15]  Rik Pintelon,et al.  System Identification: A Frequency Domain Approach , 2012 .

[16]  R Bragos,et al.  A new measuring and identification approach for time-varying bioimpedance using multisine electrical impedance spectroscopy , 2013, Physiological measurement.

[17]  Avrom Barnett,et al.  CERTAIN FACTORS AFFECTING THE CONSTANCY OF IMPEDANCE ANGLE , 1935 .

[18]  E. Barsoukov,et al.  A novel impedance spectrometer based on carrier function Laplace-transform of the response to arbitrary excitation , 2002 .

[19]  Alexander S Ross,et al.  Current source design for electrical impedance tomography. , 2003, Physiological measurement.

[20]  Yves Rolain,et al.  Broadband versus stepped sine FRF measurements , 2000, IEEE Trans. Instrum. Meas..

[21]  J. Schoukens,et al.  Basics of broadband impedance spectroscopy measurements using periodic excitations , 2012 .

[22]  Wei Wang,et al.  A high-speed bioelectrical impedance spectroscopy system based on the digital auto-balancing bridge method , 2013 .

[23]  N. Narasimhamurthi,et al.  Analysis, design, and implementation of an AC bridge for impedance measurements , 1994 .

[24]  Fernando Seoane,et al.  An analog front-end enables electrical impedance spectroscopy system on-chip for biomedical applications , 2008, Physiological measurement.

[25]  Eung Je Woo,et al.  Performance evaluation of wideband bio-impedance spectroscopy using constant voltage source and constant current source , 2012 .