An efficient pulse tube cryocooler for boil-off gas reliquefaction in liquid natural gas tanks☆

Small liquid natural gas (LNG) distribution stations require compact, highly efficient cryocoolers to reliquefy boil-off gas in the LNG tank. This paper describes a pulse tube cryocooler measuring 420mm×690mm×780mm and weighing 180kg. With low input electric power, the relative Carnot efficiency exceeded 20%. Increasing the power to 10kW, the cryocooler produced approximately 1.2kW of cooling at 120K. Approximately 295 normal cubic meters of boil-off natural gas per day can be condensed. If heat transfer in the main heat exchanger is improved, cooling power and efficiency could be further improved. This development offers an efficient, compact, and reliable configuration for energy saving in LNG distribution stations.

[1]  Ercang Luo,et al.  Detailed study of a traveling wave thermoacoustic refrigerator driven by a traveling wave thermoacoustic engine , 2006 .

[2]  Ray Radebaugh,et al.  Cryocoolers: the state of the art and recent developments , 2009, Journal of physics. Condensed matter : an Institute of Physics journal.

[3]  Scott Backhaus,et al.  Operation of Thermoacoustic Stirling Heat Engine Driven Large Multiple Pulse Tube Refrigerators , 2005 .

[4]  Ray Radebaugh,et al.  Development of the pulse tube refrigerator as an efficient and reliable cryocooler , 1999 .

[5]  K. B. Albaugh,et al.  Stirling-Type Pulse Tube Cryocooler with 1KW of Refrigeration at 77K , 2008 .

[6]  Lionel Duband,et al.  Design and prototyping of a large capacity high frequency pulse tube , 2008 .

[7]  Jalal H. Zia,et al.  A Pulse Tube Cryocooler with 300 W Refrigeration at 80 K and an Operating Efficiency of 19% Carnot , 2007 .

[8]  G. Venkatarathnam Cryogenic mixed refrigerant processes , 2008 .

[9]  Gregory Nellis,et al.  Development of a Large‐capacity, Stirling‐type, Pulse‐tube Refrigerator , 2006 .

[10]  Ercang Luo,et al.  A double-acting thermoacoustic cryocooler for high temperature superconducting electric power grids , 2013 .

[11]  Younggy Shin,et al.  Design of a boil-off natural gas reliquefaction control system for LNG carriers , 2009 .

[12]  Ercang Luo,et al.  A high-efficiency coaxial pulse tube cryocooler with 500 W cooling capacity at 80 K , 2014 .

[13]  E. Querol,et al.  Boil off gas (BOG) management in Spanish liquid natural gas (LNG) terminals , 2010 .

[14]  Daming Sun,et al.  High-power Stirling-type pulse tube cooler working below 30 K , 2009 .

[15]  P. S. Spoor Anomalous temperature and amplitude-dependent performance characteristic of a 1000W/80K coldfinger , 2014 .

[16]  Yajun Li,et al.  Flexible and cost-effective optimization of BOG (boil-off gas) recondensation process at LNG receiving terminals , 2012 .

[17]  Luwei Yang,et al.  High-power Stirling-type pulse tube cryocooler: Observation and reduction of regenerator temperature-inhomogeneities , 2007 .

[18]  Ercang Luo,et al.  Heat-driven thermoacoustic cryocooler operating at liquid hydrogen temperature with a unique coupler , 2008 .