A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical models.

Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. Unfortunately, the accurate measurement of the tissue material properties is challenging and the properties usually vary between patients. A common issue is therefore the achievable accuracy of the calculation due to the limited access to tissue elastic material constants. In this study, we performed a systematic investigation on this subject based on tissue biomechanics and computer simulations to establish the relationships between achievable registration accuracy and tissue mechanical and organ geometrical properties. Primarily we focused on image registration for three organs: rectal wall, bladder wall, and prostate. The tissue anisotropy due to orientation preference in tissue fiber alignment is captured by using an orthotropic or a transversely isotropic elastic model. First we developed biomechanical models for the rectal wall, bladder wall, and prostate using simplified geometries and investigated the effect of varying material parameters on the resulting organ deformation. Then computer models based on patient image data were constructed, and image registrations were performed. The sensitivity of registration errors was studied by perturbating the tissue material properties from their mean values while fixing the boundary conditions. The simulation results demonstrated that registration error for a subvolume increases as its distance from the boundary increases. Also, a variable associated with material stability was found to be a dominant factor in registration accuracy in the context of material uncertainty. For hollow thin organs such as rectal walls and bladder walls, the registration errors are limited. Given 30% in material uncertainty, the registration error is limited to within 1.3 mm. For a solid organ such as the prostate, the registration errors are much larger. Given 30% in material uncertainty, the registration error can reach 4.5 mm. However, the registration error distribution for prostates shows that most of the subvolumes have a much smaller registration error. A deformable organ registration technique that uses FEM is a good candidate in IGART if the mean material parameters are available.

[1]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[2]  Bostjan Likar,et al.  A hierarchical approach to elastic registration based on mutual information , 2001, Image Vis. Comput..

[3]  D. Yan,et al.  Reducing uncertainties in volumetric image based deformable organ registration. , 2003, Medical physics.

[4]  Usha Sinha,et al.  In vivo diffusion tensor imaging of the human prostate , 2004, Magnetic resonance in medicine.

[5]  J M Balter,et al.  Technical note: creating a four-dimensional model of the liver using finite element analysis. , 2002, Medical physics.

[6]  Max A. Viergever,et al.  Mutual-information-based registration of medical images: a survey , 2003, IEEE Transactions on Medical Imaging.

[7]  K Miller,et al.  Constitutive modelling of abdominal organs. , 2000, Journal of biomechanics.

[8]  T. Krouskop,et al.  Elastic Moduli of Breast and Prostate Tissues under Compression , 1998, Ultrasonic imaging.

[9]  T. Mackie,et al.  Fast free-form deformable registration via calculus of variations , 2004, Physics in medicine and biology.

[10]  A. D'Amico,et al.  Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging. , 2001, Medical physics.

[11]  S Bross,et al.  Combined evaluation of detrusor pressure and bladder wall thickness as a parameter for the assessment of detrusor function: an experimental in vivo study. , 2001, The Journal of urology.

[12]  D. Hill,et al.  Medical image registration , 2001, Physics in medicine and biology.

[13]  K. Brock,et al.  Accuracy of finite element model-based multi-organ deformable image registration. , 2005, Medical physics.

[14]  E. Pan,et al.  Measurement of mechanical properties of rectal wall , 2005, Journal of materials science. Materials in medicine.

[15]  M S Hoogeman,et al.  Dose-wall histograms and normalized dose-surface histograms for the rectum: a new method to analyze the dose distribution over the rectum in conformal radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[16]  M. Sacks,et al.  Passive biaxial mechanical properties of the rat bladder wall after spinal cord injury. , 2002, The Journal of urology.

[17]  R L Reuben,et al.  Measurement of the mechanical characteristics of benign prostatic tissue: a novel method for assessing benign prostatic disease. , 2005, Urology.

[18]  D. Yan,et al.  A model to accumulate fractionated dose in a deforming organ. , 1999, International journal of radiation oncology, biology, physics.

[19]  Bhudatt R Paliwal,et al.  Technical note: A novel boundary condition using contact elements for finite element based deformable image registration. , 2004, Medical physics.

[20]  D R Olsen,et al.  Comparative analyses of the dynamic properties of the bladder wall studied by repetitive pelvic CT scans of patients and cryo-sections of cadavers. , 2005, The British journal of radiology.