Automatic Model-Based Contour Detection and Blood Flow Quantification in Small Vessels with Velocity Encoded Magnetic Resonance Imaging

Rationale and Objectives:The quantitative assessment of blood flow in peripheral vessels from phase-contrast magnetic resonance imaging studies requires the accurate delineation of vessel contours in cross-sectional magnetic resonance images. The conventional manual segmentation approach is tedious, time-consuming, and leads to significant inter- and intraobserver variabilities. The aim of this study was to verify whether automatic model-based segmentation decreases these problems by fitting a model to the actual blood velocity profile. Methods:In this study 2 new fully automatic methods (a static and a dynamic approach) were developed and compared with manual analyzes using phantom and in vivo studies of internal carotid and vertebral arteries in healthy volunteers. The automatic segmentation approaches were based on fitting a 3D parabolic velocity model to the actual velocity profiles. In the static method, the velocity profiles were averaged over the complete cardiac cycle, whereas the dynamic method takes into account the velocity data of each cardiac time bin individually. Materials consisted of the magnetic resonance imaging data from 3 straight phantom tubes and the blood velocity profiles of 8 volunteers. Results:For the phantom studies, the automatic dynamic approach performed significantly better than the manual analysis (intraclass correlations [ICC] of 0.62–0.98 and 0.30–0.86, respectively). For the assessment of the total cerebral blood flow in the in vivo studies, the automatic static method performed significantly better than the manual 1 (ICC of 0.98–0.98 and 0.93–0.95, respectively). However, the automatic dynamic method was not significantly better than the manual 1 (ICC = 0.92–0.96) but had the advantage of providing additional parameters. Conclusion:Blood flow in magnetic resonance images of small vessels can be assessed accurately, rapidly, and fully automatically using model-based postprocessing by fitting a first approximation of the velocity profile to the actual flow data.

[1]  J. Felmlee,et al.  Cine Phase‐Contrast MR Flow Measurements: Improved Precision using an Automated Method of Vessel Detection , 1994, Journal of computer assisted tomography.

[2]  Frieke M. A. Box,et al.  Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging , 2002, Journal of magnetic resonance imaging : JMRI.

[3]  T. Scalea,et al.  Blunt splenic injuries: nonsurgical treatment with CT, arteriography, and transcatheter arterial embolization of the splenic artery. , 1991, Radiology.

[4]  J. Shepherd,et al.  Pravastatin in elderly individuals at risk of vascular disease (PROSPER): a randomized controlled trial , 2003 .

[5]  C. Rindt,et al.  Unsteady flow in a rigid 3-D model of the carotid artery bifurcation. , 1996, Journal of biomechanical engineering.

[6]  R J van der Geest,et al.  Automated measurement of volume flow in the ascending aorta using MR velocity maps: evaluation of inter- and intraobserver variability in healthy volunteers. , 1998, Journal of computer assisted tomography.

[7]  William H. Press,et al.  Numerical recipes in C , 2002 .

[8]  A. Gnasso,et al.  Association between intima-media thickness and wall shear stress in common carotid arteries in healthy male subjects. , 1996, Circulation.

[9]  A. Spilt Automated model-based contour detection and flow quantification of blood flow in small vessels with velocity encoded MRI , 1998 .

[10]  E. Laffon,et al.  Segmented 5 versus nonsegmented flow quantitation: comparison of portal vein flow measurements. , 1999, Investigative radiology.

[11]  C. Reinhold,et al.  Streamlined flow in the portal vein: Demonstration with MR angiography , 2002, Journal of magnetic resonance imaging : JMRI.

[12]  J. Debatin,et al.  Coronary flow and coronary flow reserve measurements in humans with breath‐held magnetic resonance phase contrast velocity mapping , 1997, Magnetic resonance in medicine.

[13]  P Boesiger,et al.  Quantitation of circumferential subpixel vessel wall position and wall shear stress by multiple sectored three‐dimensional paraboloid modeling of velocity encoded cine MR , 1998, Magnetic resonance in medicine.

[14]  J. Fleiss The design and analysis of clinical experiments , 1987 .

[15]  W. Mali,et al.  Effect of age on cerebral blood flow: measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults. , 1998, Radiology.

[16]  P. Macfarlane,et al.  Pravastatin in elderly individuals at risk of vascular disease (PROSPER): a randomised controlled trial , 2002, The Lancet.

[17]  A. Sawyer-Glover,et al.  Renal blood flow: measurement in vivo with rapid spiral MR imaging. , 1998, Radiology.

[18]  M. Viergever,et al.  MR phase‐contrast flow measurement with limited spatial resolution in small vessels: Value of model‐based image analysis , 1999, Magnetic resonance in medicine.

[19]  P. Macfarlane,et al.  The design of a prospective study of Pravastatin in the Elderly at Risk (PROSPER). PROSPER Study Group. PROspective Study of Pravastatin in the Elderly at Risk. , 1999, The American journal of cardiology.