Impact of Decorrelation Techniques on Sampling Noise in Radio-Frequency Applications

Analog-to-digital converter (ADC) noise limits the dynamic range of many radio-frequency systems for test and measurement, sensor, and communications applications. Improvements in the total dynamic range (as measured by the SNR) can be achieved by combining M ADCs in parallel, yielding an increase in SNR of M if the noise is fully uncorrelated across ADC units. However, the presence of correlated noise will limit the SNR improvement to a factor less than M. Noise in an ADC is due to thermal processes, quantization, and clock jitter. In an array of ADCs, thermal and quantization noise are independently generated in each ADC, but if a common clock is used, its jitter will generate correlated sampling noise in all the ADCs in the array. In this paper, we analyze and experimentally measure the impact of previously proposed harmonic decorrelation techniques on the sampling noise of an array of parallel ADCs driven by a common clock, sampling at an intermediate frequency. Both theory and experiments reveal that the decorrelation techniques reduce the total sampling noise by half, which is a result that could substantially relax clock requirements for high-dynamic-range systems and thus reduce clock costs.

[1]  J. Gray,et al.  A Precision Sample and Hold Circuit with Subnanosecond Switching , 1964 .

[2]  Ulrich L. Rohde,et al.  Microwave and Wireless Synthesizers , 2021 .

[3]  L. Cordesses,et al.  Direct digital synthesis: a tool for periodic wave generation (part 1) , 2004, IEEE Signal Processing Magazine.

[4]  K.C. Lauritzen,et al.  High-Dynamic-Range Receivers for Digital Beam Forming Radar Systems , 2007, 2007 IEEE Radar Conference.

[5]  D. J. Rabideau,et al.  Mitigation of digital array nonlinearities , 2001, Proceedings of the 2001 IEEE Radar Conference (Cat. No.01CH37200).

[6]  D.J. Rabideau,et al.  Mitigation of correlated non-linearities in digital phased arrays using channel-dependent phase shifts , 2003, IEEE MTT-S International Microwave Symposium Digest, 2003.

[7]  Andreas Wiesbauer,et al.  On the jitter requirements of the sampling clock for analog-to-digital converters , 2002 .

[8]  Roar Skartlien,et al.  Quantization error and resolution in ensemble averaged data with noise , 2005, IEEE Transactions on Instrumentation and Measurement.

[9]  D.J. Rabideau,et al.  Correlation of nonlinear distortion in digital phased arrays: measurement and mitigation , 2002, 2002 IEEE MTT-S International Microwave Symposium Digest (Cat. No.02CH37278).

[10]  A. Papoulis,et al.  Error analysis in sampling theory , 1966 .

[11]  F. L. Walls PM and AM noise of combined signal sources , 2003, IEEE International Frequency Control Symposium and PDA Exhibition Jointly with the 17th European Frequency and Time Forum, 2003. Proceedings of the 2003.

[12]  E. Seifert,et al.  Enhancing the dynamic range of analog-to-digital converters by reducing excess noise , 1989, Conference Proceeding IEEE Pacific Rim Conference on Communications, Computers and Signal Processing.

[13]  Yun Chiu,et al.  A mixed-signal MIMO beamforming receiver , 2008, 2008 IEEE Radio and Wireless Symposium.

[14]  Walt Kester,et al.  The data conversion handbook , 2005 .

[15]  Hae-Moon Seo,et al.  Relationship between ADC performance and requirements of digital-IF receiver for WCDMA base-station , 2003, IEEE Trans. Veh. Technol..

[16]  H. Kobayashi,et al.  Aperture jitter effects in wideband sampling systems , 1999, IMTC/99. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference (Cat. No.99CH36309).

[17]  Eric A. M. Klumperink,et al.  Jitter requirements of the sampling clock in software radio receivers , 2006, IEEE Transactions on Circuits and Systems II: Express Briefs.

[18]  K. A. Stewart Effect of sample clock jitter on IF-sampling IS-95 receivers , 1997, Proceedings of 8th International Symposium on Personal, Indoor and Mobile Radio Communications - PIMRC '97.

[19]  E. Sanchez-Sinencio,et al.  System design considerations of wideband multi-standard receiver for 3rd generation mobile system applications , 2000, 2000 Southwest Symposium on Mixed-Signal Design (Cat. No.00EX390).

[20]  Y. Akazawa,et al.  Jitter analysis of high-speed sampling systems , 1990 .

[21]  F. Stanke,et al.  Clock and trigger jitter. Effects on ultrasonic spectroscopy , 1988, IEEE 1988 Ultrasonics Symposium Proceedings..

[22]  W.S. Song A new 3-GSPS 65-GOPS UHF digital radar receiver and its performance characteristics , 1997, Conference Record of the Thirty-First Asilomar Conference on Signals, Systems and Computers (Cat. No.97CB36136).

[23]  D.V. Bogomolov Two Crystals and Frequency Pulling in Precision 100 MHz OCXO. , 2006, 2006 IEEE International Frequency Control Symposium and Exposition.

[24]  Rob Reeder,et al.  Pushing the State of the Art with Multichannel A/D Converters , 2005 .