Synchronized Phasor Data Based Energy Function Analysis of Dominant Power Transfer Paths in Large Power Systems

Many large interconnected power systems such as the U.S. eastern interconnection and the U.S. western power system are characterized by many power transfer paths or interfaces with high loading. Disruptions of these transfer paths frequently lead to increased loading on neighboring transfer paths, which themselves will become less secure and could cause further disruptions. State estimators have limited performance under large system disruptions, because of low sampling rates and potentially poor solution quality due to topology errors. Furthermore, disruptions in external power systems cannot be readily seen by control room operators because most state estimators only use reduced models for external systems. A system of well-placed phasor measurement units (PMUs) that provide voltage and current magnitude and phase at a high sampling rate can provide useful system dynamic security information. In this paper we apply energy function analysis using phasor data to monitor the dynamic status of power transfer paths. The ideas will be illustrated using actual data captured by several PMUs in the U.S. western power system

[1]  D. N. Kosterev,et al.  Feasibility study of using synchronized phasor measurements for generator dropping controls in the Colstrip System , 1998 .

[2]  Arun G. Phadke,et al.  Adaptive transmission system relaying , 1988 .

[3]  K.R. Padiyar,et al.  Online detection of loss of synchronism using energy function criterion , 2006, IEEE Transactions on Power Delivery.

[4]  J. F. Hauer,et al.  Application of Prony analysis to the determination of modal content and equivalent models for measured power system response , 1991 .

[5]  D. Kosterev,et al.  A new thermal governor modeling approach in the WECC , 2003 .

[6]  Joe H. Chow,et al.  Time-Scale Modeling of Dynamic Networks with Applications to Power Systems , 1983 .

[7]  Hadi Saadat,et al.  Power System Analysis , 1998 .

[8]  Vijay Vittal,et al.  Power System Transient Stability Analysis Using the Transient Energy Function Method , 1991 .

[9]  C. W. Taylor,et al.  Model validation for the August 10, 1996 WSCC system outage , 1999 .

[10]  A.R. Messina,et al.  Online assessment and control of transient oscillations damping , 2004, IEEE Transactions on Power Systems.

[11]  J. Thorp,et al.  The closest unstable equilibrium point method for power system dynamic security assessment , 1987, 26th IEEE Conference on Decision and Control.

[12]  S. E. Stanton,et al.  Application of phasor measurements and partial energy analysis in stabilizing large disturbances , 1995 .

[13]  A.G. Phadke,et al.  Adaptive out-of-step relaying using phasor measurement techniques , 1993, IEEE Computer Applications in Power.

[14]  K. R. Padiyar,et al.  ENERGY FUNCTION ANALYSIS FOR POWER SYSTEM STABILITY , 1990 .

[15]  J. Thorp,et al.  A New Measurement Technique for Tracking Voltage Phasors, Local System Frequency, and Rate of Change of Frequency , 1983, IEEE Transactions on Power Apparatus and Systems.

[16]  Graham Rogers,et al.  Power System Oscillations , 1999 .

[17]  P. Kundur,et al.  Power system stability and control , 1994 .

[18]  J. F. Hauer,et al.  Keeping an eye on power system dynamics , 1997 .