Robust control law strategy based on high order sliding mode: towards a muscle control

Functional electrical stimulation (FES) is used to excite paralysed muscles that would otherwise be uncontrollable by paraplegic patients. Consequently, the patient could recover partially some of lower limb functions improving the cardiovascular system, increasing oxygen uptake and bettering the whole quality of life. In this paper, we apply a control design based on a higher order sliding mode to a complex physio-mathematical muscle model. This model is based on macroscopic Hill and microscopic Huxley concepts. The main goal concerns the prediction of the needed pattern stimulation (current and pulse width), which will extend the overall performances and defer the muscle fatigue as much as possible. The controller is mathematically computed and shown to provide satisfactory stability and tracking errors. Its efficiency is illustrated with the control of the knee joint angle under a co-contraction approach.

[1]  Poboroniuc,et al.  Closed-Loop Control for FES-based Restoration of Standing in Paraplegia , 2003 .

[2]  David A. Winter,et al.  Biomechanics and Motor Control of Human Movement , 1990 .

[3]  T Bajd,et al.  Use of a two-channel functional electrical stimulator to stand paraplegic patients. , 1981, Physical therapy.

[4]  Valérie Kromer Analyse des forces musculaires au cours de la marche : approche en corps rigide et simulation en mécanismes plans flexibles par éléments finis , 1993 .

[5]  T. Boukhobza,et al.  High order sliding modes , 1998 .

[6]  N de N Donaldson,et al.  FES standing: control by handle reactions of leg muscle stimulation (CHRELMS). , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[7]  A. J. Mulder,et al.  On/off control in FES-induced standing up: A model study and experiments , 1992, Medical and Biological Engineering and Computing.

[8]  Poboroniuc,et al.  Closed-Loop Control for FES-Supported Standing-Up and Sitting-Down , 2002 .

[9]  Philippe Poignet,et al.  Mathematical muscle model for functional electrical stimulation control strategies , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[10]  A. Levant Sliding order and sliding accuracy in sliding mode control , 1993 .

[11]  Control of the Knee Joint Under Functional Electrical Stimulation: Simulation Results Based on a New Physiological Muscle Model , 2004 .

[12]  P. Crago,et al.  Nonlinear joint angle control for artificially stimulated muscle , 1992, IEEE Transactions on Biomedical Engineering.

[13]  Guiraud Makssoud HEL,et al.  Enhancement of physiological and mechanical modelling of the skeletal muscle controlled by Functional Electrical Stimulation , 2004 .

[14]  R Riener,et al.  Patient-driven control of FES-supported standing up: a simulation study. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[15]  R. Riener,et al.  Model-based control of FES-induced single joint movements , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.