Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running

Background Wearable sensors enable long-term monitoring of health and wellbeing indicators. An objective evaluation of sensors’ accuracy is important, especially for their use in health care. Objective The aim of this study was to use a wrist-worn optical heart rate (OHR) device to estimate heart rate (HR), energy expenditure (EE), and maximal oxygen intake capacity (VO2Max) during running and to evaluate the accuracy of the estimated parameters (HR, EE, and VO2Max) against golden reference methods. Methods A total of 24 healthy volunteers, of whom 11 were female, with a mean age of 36.2 years (SD 8.2 years) participated in a submaximal self-paced outdoor running test and maximal voluntary exercise test in a sports laboratory. OHR was monitored with a PulseOn wrist-worn photoplethysmographic device and the running speed with a phone GPS sensor. A physiological model based on HR, running speed, and personal characteristics (age, gender, weight, and height) was used to estimate EE during the maximal voluntary exercise test and VO2Max during the submaximal outdoor running test. ECG-based HR and respiratory gas analysis based estimates were used as golden references. Results OHR was able to measure HR during running with a 1.9% mean absolute percentage error (MAPE). VO2Max estimated during the submaximal outdoor running test was closely similar to the sports laboratory estimate (MAPE 5.2%). The energy expenditure estimate (n=23) was quite accurate when HR was above the aerobic threshold (MAPE 6.7%), but MAPE increased to 16.5% during a lighter intensity of exercise. Conclusions The results suggest that wrist-worn OHR may accurately estimate HR during running up to maximal HR. When combined with physiological modeling, wrist-worn OHR may be used for an estimation of EE, especially during higher intensity running, and VO2Max, even during submaximal self-paced outdoor recreational running.

[1]  Hyun-Sung An,et al.  How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough? , 2016, BMJ Open Sport & Exercise Medicine.

[2]  R. Furberg,et al.  Systematic review of the validity and reliability of consumer-wearable activity trackers , 2015, International Journal of Behavioral Nutrition and Physical Activity.

[3]  P. Montgomery,et al.  Validation of Heart Rate Monitor-Based Predictions of Oxygen Uptake and Energy Expenditure , 2009, Journal of strength and conditioning research.

[4]  An Energy Expenditure Estimation Method Based on Heart Rate Measurement , 2007 .

[5]  J. B. Weir New methods for calculating metabolic rate with special reference to protein metabolism , 1949, The Journal of physiology.

[6]  Alain P. Gauthier,et al.  Validating the Use of Heart Rate Variability for Estimating Energy Expenditure , 2015 .

[7]  Victor M Reis,et al.  Higher Precision of Heart Rate Compared with VO2 to Predict Exercise Intensity in Endurance-Trained Runners. , 2011, Journal of sports science & medicine.

[8]  U. Wisløff,et al.  Accuracy of Heart Rate Watches: Implications for Weight Management , 2016, PloS one.

[9]  Aurélien Pichon,et al.  Improvement of energy expenditure prediction from heart rate during running , 2014, Physiological measurement.

[10]  Mohamed Ismail Nounou,et al.  Are Currently Available Wearable Devices for Activity Tracking and Heart Rate Monitoring Accurate, Precise, and Medically Beneficial? , 2015, Healthcare informatics research.

[11]  T. Noakes,et al.  Prediction of energy expenditure from heart rate monitoring during submaximal exercise , 2005, Journal of sports sciences.

[12]  B R Londeree,et al.  The Use of Laboratory Test Results with Long Distance Runners , 1986, Sports medicine.

[13]  Luke Haile,et al.  Validation of the Mio Alpha Heart Rate Monitor during Graded Exercise Testing in Trail Runners: 849 Board #245 May 27, 2 , 2015 .

[14]  Automated Fitness Level ( VO 2 max ) Estimation with Heart Rate and Speed Data , 2014 .

[15]  Steven Francis Leboeuf,et al.  Earbud-based sensor for the assessment of energy expenditure, HR, and VO2max. , 2014, Medicine and science in sports and exercise.

[16]  Adrian Tarniceriu,et al.  Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[17]  A E Jeukendrup,et al.  Measurement of substrate oxidation during exercise by means of gas exchange measurements. , 2005, International journal of sports medicine.

[18]  Zohn Rosen,et al.  Validation of photoplethysmography as a method to detect heart rate during rest and exercise , 2015, Journal of medical engineering & technology.

[19]  B. Dolezal,et al.  Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking. , 2016, Journal of sports science & medicine.

[20]  James A Levine,et al.  Variability in energy expenditure and its components , 2004, Current opinion in clinical nutrition and metabolic care.

[21]  Hirofumi Tanaka,et al.  Age-predicted maximal heart rate revisited. , 2001, Journal of the American College of Cardiology.

[22]  Jakub Parák,et al.  Evaluation of wearable consumer heart rate monitors based on photopletysmography , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.