Expanding the capabilities of microfluidic gradient elution moving boundary electrophoresis for complex samples.

Gradient elution moving boundary electrophoresis (GEMBE) is a robust, continuous injection separation technique that uses electrophoresis to drive electrically charged analytes into a capillary or microfluidic channel for detection, while opposing electroosmosis and controlled variable pressure-driven flow prevent other sample components-for example, cells, proteins, or particulates in complex samples that can interfere with analysis-from entering the channel. This work expands the sample-in/answer-out analytical capabilities of GEMBE for complex samples by demonstrating the quantitative analysis of anions, implementing aqueous background electrolyte (BGE) solutions at neutral pH, and introducing the use of additives to the sample solution to optimize performance. Dirt was analyzed quantitatively, with the sole preparatory step of suspension in an aqueous BGE solution at neutral pH, for dissolved chloride, nitrite, nitrate, sulfate, and oxalate using GEMBE with capacitively-coupled contactless conductivity detection. In addition to altering the pH of the BGE solution, optimization of the analysis of dirt and whole blood was achieved using various commercially available additives. These results, taken together with previous demonstrations of GEMBE for the analysis of complex samples, underscore the uncomplicated versatility of GEMBE, facilitate effective analysis of biological complex samples using BGE solutions at physiological pH, and offer a sufficient set of techniques and tools to build a foundation for the analysis of a broad range of complex samples.

[1]  Detlev Belder,et al.  Surface modification in microchip electrophoresis , 2003, Electrophoresis.

[2]  Duncan Thorburn Burns,et al.  Use of the term "recovery" and "apparent recovery" in analytical procedures (IUPAC Recommendations 2002) , 2002 .

[3]  L. Locascio,et al.  Counterflow rejection of adsorbing proteins for characterization of biomolecular interactions by temperature gradient focusing. , 2008, Analytical chemistry.

[4]  D. Ross,et al.  Gradient elution isotachophoresis for enrichment and separation of biomolecules. , 2007, Analytical chemistry.

[5]  Alberto Escarpa,et al.  Real sample analysis on microfluidic devices. , 2007, Talanta.

[6]  D. Ross,et al.  Gradient elution moving boundary electrophoresis for high-throughput multiplexed microfluidic devices. , 2007, Analytical chemistry.

[7]  V. Dolnik,et al.  Wall coating for capillary electrophoresis on microchips , 2004, Electrophoresis.

[8]  V. Dolnik,et al.  Polymer wall coatings for capillary electrophoresis , 2001, Electrophoresis.

[9]  Paul M. Flanigan,et al.  Determination of inorganic ions in mineral water by gradient elution moving boundary electrophoresis , 2010, Electrophoresis.

[10]  E. Strychalski,et al.  Microfluidic analysis of complex samples with minimal sample preparation using gradient elution moving boundary electrophoresis. , 2009, Analytical chemistry.

[11]  D. Ross,et al.  Simple device for multiplexed electrophoretic separations using gradient elution moving boundary electrophoresis with channel current detection. , 2008, Analytical chemistry.

[12]  R. Zengerle,et al.  Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. , 2010, Chemical Society reviews.

[13]  Rosanne M Guijt,et al.  Conductivity detection for conventional and miniaturised capillary electrophoresis systems , 2004, Electrophoresis.

[14]  P. Hauser,et al.  Ten years of axial capacitively coupled contactless conductivity detection for CZE – a review , 2009, Electrophoresis.

[15]  Gradient counterflow electrophoresis methods for bioanalysis. , 2010, Bioanalysis.