A concept of capillary active, dynamic insulation integrated with heating, cooling and ventilation, air conditioning system

When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation, one needs to use interior thermal insulation systems. Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges. Yet they may be successfully used and, in many instances, are recommended as a complement to the exterior insulation. This paper presents one of these cases. It is focused on the most successful applications of capillary active, dynamic interior thermal insulation. This happens when such insulation is integrated with heating, cooling and ventilation, air conditioning (HVAC) system. Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations, we propose a next generation, namely, a bio-fiber thermal insulation. When completing the review, this paper proposes a concept of a joint research project to be undertaken by partners from the US (where improvement of indoor climate in exposed coastal areas is needed), China (indoor climate in non-air conditioned concrete buildings is an issue), and Germany (where the bio-fiber technology has been developed).

[1]  R. P. Tye,et al.  Thermal transmission measurements of insulation : a symposium , 1978 .

[2]  Staf Roels,et al.  A Comparison of the Nordtest and Japanese Test Methods for the Moisture Buffering Performance of Building Materials , 2006 .

[3]  Mark Bomberg,et al.  Influence of Moisture and Moisture Gradients on Heat Transfer Through Porous Building Materials , 1978 .

[4]  Carey J. Simonson,et al.  Heat and Mass Transfer between Indoor Air and a Permeable and Hygroscopic Building Envelope: Part I – Field Measurements , 2004 .

[5]  Dirk Saelens,et al.  Experimental Evaluation of Airflow in Naturally Ventilated Active Envelopes , 2001 .

[6]  Carsten Rode,et al.  Moisture Buffering and its Consequence in Whole Building Hygrothermal Modeling , 2008 .

[7]  Hugo Hens,et al.  Effects of Air and Moisture Flows on the Thermal Performance of Insulations in Ventilated Roofs and Walls , 1996 .

[8]  Mark Bomberg,et al.  Integrated Methodology for Evaluation of Energy Performance of the Building Enclosures — Part 1: Test Program Development , 2008 .

[9]  Arild Gustavsen,et al.  The path to the high performance thermal building insulation materials and solutions of tomorrow , 2010 .

[10]  Hussein Abaza Utilizing Latent Building Thermal Mass for Dehumidification , 2005 .

[11]  Carey J. Simonson,et al.  Moisture Performance of an Airtight, Vapor-permeable Building Envelope in a Cold Climate , 2005 .

[12]  Carey J. Simonson,et al.  Heat and Mass Transfer between Indoor Air and a Permeable and Hygroscopic Building Envelope: Part II – Verification and Numerical Studies , 2004 .

[13]  Russell Richman,et al.  More Sustainable Masonry Façades: Preheating Ventilation Air Using a Dynamic Buffer Zone , 2010 .

[14]  Mark Bomberg,et al.  Integrated Methodology for Evaluation of Energy Performance of Building Enclosures: Part II — Examples of Application to Residential Walls , 2008 .