Intensity-based 2-D - 3-D registration of cerebral angiograms

We propose a new method for aligning three-dimensional (3-D) magnetic resonance angiography (MRA) with 2-D X-ray digital subtraction angiograms (DSA). Our method is developed from our algorithm to register computed tomography volumes to X-ray images based on intensity matching of digitally reconstructed radiographs (DRRs). To make the DSA and DRR more similar, we transform the MRA images to images of the vasculature and set to zero the contralateral side of the MRA to that imaged with DSA. We initialize the search for a match on a user defined circular region of interest. We have tested six similarity measures using both unsegmented MRA and three segmentation variants of the MRA. Registrations were carried out on images of a physical neuro-vascular phantom and images obtained during four neuro-vascular interventions. The most accurate and robust registrations were obtained using the pattern intensity, gradient difference, and gradient correlation similarity measures, when used in conjunction with the most sophisticated MRA segmentations. Using these measures, 95% of the phantom start positions and 82% of the clinical start positions were successfully registered. The lowest root mean square reprojection errors were 1.3 mm (standard deviation 0.6) for the phantom and 1.5 mm (standard deviation 0.9) for the clinical data sets. Finally, we present a novel method for the comparison of similarity measure performance using a technique borrowed from receiver operator characteristic analysis.

[1]  D N Levin,et al.  Retrospective registration of X‐ray angiograms with MR images by using vessels as intrinsic landmarks , 1994, Journal of magnetic resonance imaging : JMRI.

[2]  Grégoire Malandain,et al.  Matching 3D MR angiography data and 2D X-ray angiograms , 1997, CVRMed.

[3]  T. Boult,et al.  Registration of planar film radiographs with computed tomography , 1996, Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis.

[4]  J. Alison Noble,et al.  Real-Time Registration of 3D Cerebral Vessels to X-ray Angiograms , 1998, MICCAI.

[5]  Jürgen Weese,et al.  Voxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery , 1997, IEEE Transactions on Information Technology in Biomedicine.

[6]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[7]  J V Byrne Acute endovascular treatment by coil embolisation of ruptured intracranial aneurysms. , 2001, Annals of the Royal College of Surgeons of England.

[8]  Alan Liu,et al.  3D/2D Registration via Skeletal Near Projective Invariance in Tubular Objects , 1998, MICCAI.

[9]  J. Alison Noble,et al.  Statistical 3D Vessel Segmentation Using a Rician Distribution , 1999, MICCAI.

[10]  Jürgen Weese,et al.  Image registration: convex weighting functions for histogram-based similarity measures , 1997, CVRMed.

[11]  Robert J. Maciunas,et al.  Registration of head volume images using implantable fiducial markers , 1997, IEEE Transactions on Medical Imaging.

[12]  S. Rudin,et al.  Accurate characterization of image intensifier distortion. , 1991, Medical physics.

[13]  Jürgen Weese,et al.  A comparison of similarity measures for use in 2-D-3-D medical image registration , 1998, IEEE Transactions on Medical Imaging.

[14]  Erhard Klotz,et al.  Real-Time Distortion Correction Of Digital X-Ray II/TV Systems: An Application Example , 1989, Other Conferences.

[15]  J. Alison Noble,et al.  Fusing speed and phase information for vascular segmentation of phase contrast MR angiograms , 2002, Medical Image Anal..

[16]  Benoit M. Dawant,et al.  Retrospective intermodality registration techniques for images of the head: surface-based versus volume-based , 1999, IEEE Transactions on Medical Imaging.

[17]  David J. Hawkes,et al.  A Comparison of 2D-3D Intensity-Based Registration and Feature-Based Registration for Neurointerventions , 2002, MICCAI.

[18]  D L Hill,et al.  Validation of a two- to three-dimensional registration algorithm for aligning preoperative CT images and intraoperative fluoroscopy images. , 2001, Medical physics.

[19]  Hiroshi Iseki,et al.  Interactive virtualized display system for intravascular neurosurgery , 1997, CVRMed.

[20]  Guy Marchal,et al.  Multi-modality image registration by maximization of mutual information , 1996, Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis.

[21]  Y Trousset,et al.  Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment. , 2001, Radiology.

[22]  G. Marchal,et al.  Multi-modal volume registration by maximization of mutual information , 1997 .

[23]  D. R. Fish,et al.  A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs. , 1994, Medical physics.