A computer method to analyse the impact of ultrasound frequency on the brightness of USG images of muscle cross-sections

A total number of 270 ultrasound images of m. longissimus behind the 13th thoracic vertebrae were obtained on 90 lamb carcasses. Three different scanning frequencies were used (5.0, 7.5 and 10.0 MHz) in order to analyse how the frequency of the ultrasound wave affects the changes of pixel brightness in the ultrasound image. In the images obtained with 10 MHz probe the brightness of the 1st region was higher by 27% and 25% (P≤0.01) compared to the same region of images obtained with 5 MHz and 7.5 MHz frequency probe. The 3rd region of muscle cross-sections obtained with 10 MHz frequency was very dark, with the brightness lower by 22,5% and 28,3% compared to the same region of images obtained with 5 MHz and 7.5 MHz frequency. In the images obtained with 10 MHz scanning frequency, the decrease of brightness from the 1st to the 3rd region of the image was very sharp. While in the images obtained by means of 5 and 7.5 MHz ultrasound frequency, the brightness changes between the regions were very fluent. To conclude, the results of the presented research reveal that high ultrasound frequency has a negative impact on ultrasound image brightness and may reduce the information value of the image.

[1]  A. R. Williams Ultrasound applications in beef cattle carcass research and management , 2002 .

[2]  Steven J. Moeller,et al.  Evolution and use of ultrasonic technology in the swine industry , 2002 .

[3]  P. Ślósarz,et al.  The live ultrasound measurements to assess slaughter value of meat-type male kids , 2004 .

[4]  D. Lisiak,et al.  Estimation of intramuscular level of marbling among Whiteheaded Mutton Sheep lambs , 2016 .

[5]  D. Boggs,et al.  Live animal carcass evaluation and selection manual , 1984 .

[6]  P. Ślósarz,et al.  Assessment of intramuscular fat content in the longissimus dorsi muscle in live lambs on the basis of ultrasound image , 2001 .

[7]  C. Pomar,et al.  Accuracy of real-time ultrasound measurements of total tissue, fat, and muscle depths at different measuring sites in lamb. , 2009, Journal of animal science.

[8]  Kay Raum,et al.  Ultrasound velocity and attenuation of porcine soft tissues with respect to structure and composition: II. Skin and backfat. , 2011, Meat science.

[9]  Piotr Boniecki,et al.  Different methods of image segmentation in the process of meat marbling evaluation , 2015, Digital Image Processing.

[10]  Bogdan Ciszek,et al.  Editorial Comment on: Zbigniew Czyrny Muscles – histology, micro/macroanatomy and US anatomy, a brand new perspective , 2012, Journal of ultrasonography.

[11]  Piotr Boniecki,et al.  Marbling classification of lambs carcasses with the artificial neural image analysis , 2015, Digital Image Processing.

[12]  T. Baas,et al.  Prediction of intramuscular fat percentage in live swine using real-time ultrasound. , 2002, Journal of animal science.

[13]  A. Pakdel,et al.  Accuracy of Real-time Ultrasonography in Assessing Carcass Traits in Torki-Ghashghaii Sheep , 2014 .