Intravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: feasibility study in rabbits.

PURPOSE To develop a technique for intravascular magnetic resonance (MR)-guided balloon angioplasty with use of an MR imaging guide wire. MATERIALS AND METHODS An MR imaging guide wire (0.6-mm loopless antenna) that could be placed within a balloon catheter was manufactured. The guide wire was expected to function as either an MR receiver probe in real-time MR imaging or a guide wire for use with interventional devices. Laparotomy was performed in eight rabbits, and a dilatable stenosis was created at the upper abdominal aorta. Balloon angioplasty, validated at pre- and postoperative MR aortography with renal contrast enhancement was performed by using a 1.5-T MR unit with a fast spoiled gradient-echo pulse sequence, short repetition and echo times, and a rate of three frames per second. RESULTS During MR tracking, the entire length of the MR imaging guide wire was always visible as a band of high signal intensity. In all cases, the MR imaging guide wires were passed through the aortic stenoses dilated by means of balloon inflation. Before balloon angioplasty, flow in the aorta distal to the stenosis was decreased, which caused mild contrast enhancement in each kidney. After balloon angioplasty, distal flow was restored, resulting in substantial renal enhancement. CONCLUSION The MR imaging guide wire is a potential tool for use in endovascular interventional MR imaging.

[1]  E. Atalar,et al.  Intravascular MR imaging and intravascular MR-guided interventions. , 1999, International journal of cardiovascular interventions.

[2]  H. K. Charles,et al.  Catheter‐tracking FOV MR fluoroscopy , 1998, Magnetic resonance in medicine.

[3]  E Atalar,et al.  Intravascular MR-monitored balloon angioplasty: an in vivo feasibility study. , 1998, Journal of vascular and interventional radiology : JVIR.

[4]  R W Günther,et al.  Invited. Visualization of MR‐compatible catheters by electrically induced local field inhomogeneities: Evaluation in vivo , 1998, Journal of magnetic resonance imaging : JMRI.

[5]  K J Zuiderveld,et al.  MR‐guided balloon angioplasty: In vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions , 1998, Journal of magnetic resonance imaging : JMRI.

[6]  M Wendt,et al.  Shifted rotated keyhole imaging and active tip‐tracking for interventional procedure guidance , 1998, Journal of magnetic resonance imaging : JMRI.

[7]  J. Debatin,et al.  Active MR visualization of a vascular guidewire in vivo , 1998, Journal of magnetic resonance imaging : JMRI.

[8]  E Atalar,et al.  Intravascular magnetic resonance imaging of aortic atherosclerotic plaque composition. , 1997, Arteriosclerosis, thrombosis, and vascular biology.

[9]  J F Debatin,et al.  Intravascular MR imaging of atherosclerotic plaque: ex vivo analysis of human femoral arteries with histologic correlation. , 1997, Radiology.

[10]  R W Günther,et al.  Catheter visualization using locally induced, actively controlled field inhomogeneities , 1997, Magnetic resonance in medicine.

[11]  Ogan Ocali,et al.  Intravascular magnetic resonance imaging using a loopless catheter antenna , 1997, Magnetic resonance in medicine.

[12]  P. Batchelor,et al.  International Society for Magnetic Resonance in Medicine , 1997 .

[13]  M A Viergever,et al.  MR-guided endovascular interventions: susceptibility-based catheter and near-real-time imaging technique. , 1997, Radiology.

[14]  V. Fuster,et al.  Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo. , 1996, Circulation.

[15]  C L Dumoulin,et al.  Intravascular MR tracking catheter: preliminary experimental evaluation. , 1995, AJR. American journal of roentgenology.

[16]  G. Mckinnon,et al.  Vascular interventions guided by ultrafast MR imaging: Evaluation of different materials , 1994, Magnetic resonance in medicine.