The EOS™ imaging system and its uses in daily orthopaedic practice

BackgroundThe EOS™ X-ray machine, based on a Nobel prize-winning invention in physics in the field of particle detection, is capable of a simultaneous capture of biplanar X-ray images by slot scanning of the whole body in an upright, physiological load-bearing position, using ultra-low radiation doses. The simultaneous capture of spatially calibrated anterioposterior and lateral images provides a three-dimensional (3D) surface reconstruction of the skeletal system using a special software. Parts of the skeletal system in X-ray images and 3D-reconstructed models appear in true 1:1 scale for size and volume, thus spinal and vertebral parameters, lower limb axis lengths and angles, as well as any relevant clinical parameters in orthopaedic practice can be very precisely measured and calculated. Visualisation of 3D reconstructed models in various views by sterEOS 3D software enables presentation of top view images to help analyse rotational conditions of lower limbs, joints and spine deformities in the horizontal plane, providing revolutionary novel possibilities in orthopaedic surgery, especially in spine surgery. Approach and conclusionsOur department has been extensively using the very first commercially available EOS™ imaging system worldwide for routine orthopaedic diagnostics since June 2007. During this period of about 4.5 years, more than 5,700 standard examinations have been carried out, about a third of them in spine deformity cases and the rest in lower limb orthopaedic cases. In this mini-review, general principles and uses of this groundbreaking integrated orthopaedic solution is reviewed with a few highlighted examples from our own clinical practice.

[1]  W. Skalli,et al.  Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique , 2001, Medical and Biological Engineering and Computing.

[2]  E. Karlsson The Nobel Prize in Physics , 2001 .

[3]  D Mitton,et al.  3D detailed reconstruction of vertebrae with low dose digital stereoradiography. , 2002, Studies in health technology and informatics.

[4]  P. Than,et al.  Geometrical values of the normal and arthritic hip and knee detected with the EOS imaging system , 2012, International Orthopaedics.

[5]  D Mitton,et al.  A Biplanar Reconstruction Method Based on 2D and 3D Contours: Application to the Distal Femur , 2003, Computer methods in biomechanics and biomedical engineering.

[6]  G. Charpak La détection des particules , 1981 .

[7]  Catherine Adamsbaum,et al.  Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children , 1998, Pediatric Radiology.

[8]  Gilles Beaudoin,et al.  Evaluation of a full-scale gas microstrip detector for low-dose X-ray imaging , 2005 .

[9]  David Mitton,et al.  3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes , 2000, Medical and Biological Engineering and Computing.

[10]  Georges Charpak,et al.  Une nouvelle imagerie Ostéo-Articulaire basse dose en position debout : le système EOS , 2005 .

[11]  W. Skalli,et al.  Le système EOS. Nouvelle imagerie Ostéo-Articulaire basse dose en position debout , 2005 .