System-Level Tests of Transformer Differential Protection Using an IEC 61850 Process Bus

The IEC 61850 family of standards for substation communication systems was released in the early 2000s and includes IEC 61850-8-1 and IEC 61850-9-2 that enable Ethernet to be used for process-level connections between transmission substation switchyards and control rooms. This paper presents an investigation of process bus protection performance, since the inservice behavior of multifunction process buses is largely unknown. An experimental approach was adopted that used a Real Time Digital Simulator and “live” substation automation devices. The effect of sampling synchronization error and network traffic on transformer differential protection performance was assessed and compared to conventional hard-wired connections. Ethernet was used for all sampled value measurements, circuit breaker tripping, transformer tap-changer position reports, and precision time protocol synchronization of sampled value merging unit sampling. Test results showed that the protection relay under investigation operated correctly with process bus network traffic approaching 100% capacity. The protection system was not adversely affected by synchronizing errors significantly larger than the standards permit, suggesting that these requirements may be overly conservative. This “closed loop” approach, using substation automation hardware, validated the operation of protection relays under extreme conditions. Digital connections using a single shared Ethernet network outperformed conventional hard-wired solutions.

[1]  T S Sidhu,et al.  Performance of IEC 61850-9-2 Process Bus and Corrective Measure for Digital Relaying , 2011, IEEE Transactions on Power Delivery.

[2]  P. A. Crossley,et al.  Evaluation of process bus reliability , 2010 .

[3]  R. Moore,et al.  New paradigm of smart transmission substation - practical experience with Ethernet based fiber optic switchyard at 500 kilovolts , 2011, 2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies.

[4]  Duncan A. Campbell,et al.  Direct Evaluation of IEC 61850-9-2 Process Bus Network Performance , 2012, IEEE Transactions on Smart Grid.

[5]  Tarlochan Sidhu,et al.  Configuration and performance testing of IEC 61850 GOOSE , 2011, 2011 International Conference on Advanced Power System Automation and Protection.

[6]  Design and performance evaluation for a protection system utilising IEC 61850-9-2 process bus , 2011, 2011 International Conference on Advanced Power System Automation and Protection.

[7]  栄 久米原,et al.  Wiresharkパケット解析リファレンス : Network Protocol Analyzer , 2009 .

[8]  G. Ledwich,et al.  Test and evaluation system for multi-protocol sampled value protection schemes , 2011, 2011 IEEE Trondheim PowerTech.

[9]  M. Adamiak,et al.  Reducing conventional copper signaling in high voltage substations with IEC 61850 process bus system , 2009, 2009 IEEE Bucharest PowerTech.

[10]  Duncan A. Campbell,et al.  Performance Analysis of IEC 61850 Sampled Value Process Bus Networks , 2013, IEEE Transactions on Industrial Informatics.

[11]  J. Bautista Flores,et al.  FIRST MULTIVENDOR 400 KV TRANSMISSION LINE PROTECTION SCHEME USING AN IEC 61850-9-2 DIGITAL NETWORK FOR OPTICAL CTS AND PROTECTION RELAYS , 2012 .

[12]  Alessandra Flammini,et al.  Mixing Real Time Ethernet traffic on the IEC 61850 Process bus , 2012, 2012 9th IEEE International Workshop on Factory Communication Systems.

[13]  Pascal Schaub,et al.  Australia leads with process bus , 2012 .

[14]  T. S. Sidhu,et al.  Laboratory Investigation of IEC 61850-9-2-Based Busbar and Distance Relaying With Corrective Measure for Sampled Value Loss/Delay , 2011, IEEE Transactions on Power Delivery.

[15]  Duncan A. Campbell,et al.  Network Interactions and Performance of a Multifunction IEC 61850 Process Bus , 2013, IEEE Transactions on Industrial Electronics.

[16]  Duncan A. Campbell,et al.  Performance Analysis of PTP Components for IEC 61850 Process Bus Applications , 2013, IEEE Transactions on Instrumentation and Measurement.

[17]  Peter Crossley,et al.  Design and operation of the IEC61850 9–2 process bus used for the protection system , 2012 .

[18]  Rick Kuffel,et al.  Real time simulation and testing using IEC 61850 , 2010, 2010 Modern Electric Power Systems.

[19]  Duncan A. Campbell,et al.  Use of Precision Time Protocol to Synchronize Sampled-Value Process Buses , 2012, IEEE Transactions on Instrumentation and Measurement.