Simulated laparoscopy using a head-mounted display vs traditional video monitor: an assessment of performance and muscle fatigue

BackgroundThe direction of visual gaze may be an important ergonomic factor that affects operative performance. We designed a study to determine whether a head-mounted display (HMD) worn by the surgeon would improve task performance and/or reduce muscle fatigue during a laparoscopic task when compared to the use of a traditional video monitor display (VMD).MethodsSurgical residents (n = 30) were enrolled in the study. A junior group, consisting of 15 postgraduate year (PGY) = 1 subjects with no previous laparoscopic experience, and a senior group, consisting of 15 PGY 4 and PGY 5 subjects with experience, completed a laparoscopic task that was repeated four times using the Computer Enhanced Laparoscopic Training System (CELTS). Groups alternated between using the HMD with the task placed in a downward frontal position and the VMD with the task at a 30° lateral angle. The CELTS module assessed task completion time, depth perception, path length of instruments, response orientation, motion smoothness; the system then generated an overall score. Electromyography (EMG) was used to record sternocleidomastoid muscle activity. Display preference was surveyed.ResultsThe senior residents performed better than the junior residents overall on all parameters (p < 0.05) except for motion smoothness, where there was no difference. In both groups, the HMD significantly improved motion smoothness when compared to the VMD (p < 0.05). All other parameters were equal. There was less muscle fatigue when using the VMD (p < 0.05). We found that 66% of the junior residents but only 20% of the senior residents preferred the HMD.ConclusionsThe CELTS module demonstrated evidence of construct validity by differentiating the performances of junior and senior residents. By aligning the surgeon’s visual gaze with the instruments, HMD improved smoothness of motion. Experienced residents preferred the traditional monitor display. Although the VMD produced less muscle fatigue, inexperienced residents preferred the HMD, possibly because of improved smoothness of motion.

[1]  R H M Goossens,et al.  Assessment of the ergonomically optimal operating surface height for laparoscopic surgery. , 2002, Journal of laparoendoscopic & advanced surgical techniques. Part A.

[2]  M. Mueller,et al.  Three-dimensional laparoscopy , 1999, Surgical Endoscopy.

[3]  D. L. Forkey,et al.  The effect of laparoscopic instrument working angle on surgeons’ upper extremity workload , 2001, Surgical Endoscopy.

[4]  R Berguer,et al.  A virtual instrument ergonomics workstation for measuring the mental workload of performing video-endoscopic surgery. , 2000, Studies in health technology and informatics.

[5]  Warren D. Smith,et al.  Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery , 2001, Surgical Endoscopy.

[6]  H. Krueger,et al.  Direction of gaze and comfort: discovering the relation for the ergonomic optimization of visual tasks , 1994, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[7]  R Berguer,et al.  A virtual instrument ergonomics workstation to measure surgeons' physical stress. , 1999, Studies in health technology and informatics.

[8]  R Arndt,et al.  Working posture and musculoskeletal problems of video display terminal operators--review and reappraisal. , 1983, American Industrial Hygiene Association journal.

[9]  R. Berguer,et al.  Surgical technology and the ergonomics of laparoscopic instruments , 1998, Surgical Endoscopy.

[10]  D. Rattner,et al.  Computer-enhanced laparoscopic training system (CELTS): bridging the gap , 2004, Surgical Endoscopy And Other Interventional Techniques.

[11]  Fernando Molle,et al.  Identification of the preferential gaze position through evaluation of visual fatigue in a selected group of VDU operators , 2005, Documenta Ophthalmologica.

[12]  D. Rattner,et al.  CELTS: a clinically-based Computer Enhanced Laparoscopic Training System. , 2003, Studies in health technology and informatics.

[13]  R. Berguer,et al.  A comparison of surgeons' posture during laparoscopic and open surgical procedures , 1997, Surgical Endoscopy.

[14]  G. Tetteroo,et al.  Use of head-mounted display in transanal endoscopic microsurgery , 2003, Surgical Endoscopy And Other Interventional Techniques.

[15]  Warren D. Smith,et al.  Ergonomic problems associated with laparoscopic surgery , 1999, Surgical Endoscopy.

[16]  A. Cuschieri,et al.  Task performance in endoscopic surgery is influenced by location of the image display. , 1998, Annals of surgery.

[17]  R Berguer,et al.  An ergonomic evaluation of surgeons' axial skeletal and upper extremity movements during laparoscopic and open surgery. , 2001, American journal of surgery.