Regularized fieldmap estimation in MRI

In fast MR imaging with long readout times, such as echo-planar imaging (EPI) and spiral scans, it is important to correct for the effects of field inhomogeneity to reduce image distortion and blurring. Such corrections require an accurate field map, a map of the off-resonance frequency at each voxel. Standard fieldmap estimation methods yield noisy fieldmaps, particularly in image regions having low spin density. This paper describes regularized methods for fieldmap estimation. These methods exploit the fact that fieldmaps are smooth functions. Efficient convergent algorithms are given even though the problem is highly nonlinear. Results show that the proposed regularized methods significantly improve the quality of fieldmap estimates relative to conventional unregularized methods

[1]  Douglas C Noll,et al.  Iterative RF pulse design for multidimensional, small‐tip‐angle selective excitation , 2005, Magnetic resonance in medicine.

[2]  Enrico De Vita,et al.  EPI distortion correction from a simultaneously acquired distortion map using TRAIL , 2006, Journal of magnetic resonance imaging : JMRI.

[3]  Wesley E. Snyder,et al.  Magnetic Resonance Image restoration , 2005, Journal of Mathematical Imaging and Vision.

[4]  Jeffrey A. Fessler,et al.  Iterative image reconstruction in MRI with separate magnitude and phase regularization , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[5]  J. Schenck The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. , 1996, Medical physics.

[6]  Donald B Twieg Parsing local signal evolution directly from a single‐shot MRI signal: A new approach for fMRI , 2003, Magnetic resonance in medicine.

[7]  Bo Liu,et al.  JOINT ESTIMATION OF IMAGE AND COIL SENSITIVITIES IN PARALLEL SPIRAL MRI , 2006, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[8]  D G Nishimura,et al.  Inhomogeneity correction using an estimated linear field map , 1996, Magnetic resonance in medicine.

[9]  Jeffrey A. Fessler,et al.  Conjugate-gradient preconditioning methods for shift-variant PET image reconstruction , 1999, IEEE Trans. Image Process..

[10]  Michael Unser,et al.  Recursive Regularization Filters: Design, Properties, and Applications , 1991, IEEE Trans. Pattern Anal. Mach. Intell..

[11]  M. W. Jacobson,et al.  Properties of MM Algorithms on Convex Feasible Sets : Extended Version , 2004 .

[12]  Hakan Erdogan,et al.  Ordered subsets algorithms for transmission tomography. , 1999, Physics in medicine and biology.

[13]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[14]  Jeffrey A. Fessler,et al.  An Expanded Theoretical Treatment of Iteration-Dependent Majorize-Minimize Algorithms , 2007, IEEE Transactions on Image Processing.

[15]  Matthew Brett,et al.  An Evaluation of the Use of Magnetic Field Maps to Undistort Echo-Planar Images , 2003, NeuroImage.

[16]  Jeffrey A. Fessler,et al.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs , 1996, IEEE Trans. Image Process..

[17]  M. Bronskill,et al.  Noise and filtration in magnetic resonance imaging. , 1985, Medical physics.

[18]  Ewald Moser,et al.  Robust field map generation using a triple‐echo acquisition , 2004, Journal of magnetic resonance imaging : JMRI.

[19]  K. Sekihara,et al.  NMR Imaging for Magnets with Large Nonuniformities , 1985, IEEE Transactions on Medical Imaging.

[20]  Jeffrey A. Fessler,et al.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities , 2003, IEEE Transactions on Medical Imaging.

[21]  Jeffrey A. Fessler,et al.  Conjugate phase MRI reconstruction with spatially variant sample density correction , 2005, IEEE Transactions on Medical Imaging.

[22]  G. Glover Multipoint dixon technique for water and fat proton and susceptibility imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[23]  Jeffrey A. Fessler,et al.  On complete-data spaces for PET reconstruction algorithms , 1993 .

[24]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[25]  G. Glover,et al.  Rapid in vivo proton shimming , 1991, Magnetic resonance in medicine.

[26]  Jeffrey A. Fessler,et al.  Nonuniform fast Fourier transforms using min-max interpolation , 2003, IEEE Trans. Signal Process..

[27]  Jeffrey A. Fessler,et al.  Edge-preserving tomographic reconstruction with nonlocal regularization , 2002 .

[28]  D G Nishimura,et al.  Automatic field map generation and off‐resonance correction for projection reconstruction imaging , 2000, Magnetic resonance in medicine.

[29]  Jerry L. Prince,et al.  THREE-POINT METHOD FOR FAST AND ROBUST FIELD MAPPING FOR EPI GEOMETRIC DISTORTION CORRECTION , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[30]  Douglas C Noll,et al.  Dynamic field map estimation using a spiral‐in/spiral‐out acquisition , 2004, Magnetic resonance in medicine.

[31]  Alan C. Evans,et al.  MRI Simulation Based Evaluation and Classifications Methods , 1999, IEEE Trans. Medical Imaging.

[32]  D G Nishimura,et al.  Efficient off‐resonance correction for spiral imaging , 2001, Magnetic resonance in medicine.

[33]  N J Pelc,et al.  Reconstructions of phase contrast, phased array multicoil data , 1994, Magnetic resonance in medicine.

[34]  B. Lindsay,et al.  Monotonicity of quadratic-approximation algorithms , 1988 .

[35]  A M Wyrwicz,et al.  Correction for EPI distortions using multi‐echo gradient‐echo imaging , 1999, Magnetic resonance in medicine.

[36]  D. Louis Collins,et al.  Design and construction of a realistic digital brain phantom , 1998, IEEE Transactions on Medical Imaging.