Numerical and Monte Carlo Simulation for Polychromatic L-shell X-ray Fluorescence Computed Tomography Based on Pinhole Collimator with Sheet-Beam Geometry

X-ray fluorescence computed tomography (XFCT) has attracted wide attention due to its ability to simultaneously and nondestructively obtain structural and elemental distribution information within samples. In this paper, we presented an image system based on the pinhole collimator for the polychromatic L-shell XFCT to reduce time consumption and improve the detection limit. First, the imaging system model was expressed by formulas and discretized. Then, two phantoms (A and B) were scanned by numerical simulation and Monte Carlo simulation. Both phantoms with the same diameter (10 mm) and height (10 mm) were cylinders filled with PMMA, and embedded with GNP-loaded cylinders. The phantom A was inserted by six 1.5 mm-diameter cylinders with different Au concentrations ranging from 0.2% to 1.2%. The phantom B was inserted by eight cylinders with the same Au concentration (1%), but a radius ranging from 0.1 mm to 0.8 mm. Finally, the reconstruction of the XFCT images was performed using the method with and without absorption correction, respectively. The feasibility of XFCT system presented in this paper was demonstrated by the numerical simulation and the Monte Carlo simulation. The results show that absorption attenuation can be corrected by the presented method, and the contrast to noise ratio (CNR) is proportional to Au concentration but almost remains unchanged with the radius of GNP-loaded cylinders, which may provide the necessary justification for further optimization of the imaging system.

[1]  H. Carvalho,et al.  Recent advances in LIBS and XRF for the analysis of plants , 2018 .

[2]  T. Xiao,et al.  X-ray fluorescence microtomography based on polycapillary-focused X-rays from laboratory source , 2018 .

[3]  E. Donner,et al.  Application of Synchrotron Radiation-based Methods for Environmental Biogeochemistry: Introduction to the Special Section. , 2017, Journal of environmental quality.

[4]  Nivedh Manohar,et al.  Quantitative imaging of gold nanoparticle distribution in a tumor-bearing mouse using benchtop x-ray fluorescence computed tomography , 2016, Scientific Reports.

[5]  Lei Xing,et al.  Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study , 2015, Journal of medical imaging.

[6]  M. Bazalova-Carter The potential of L-shell X-ray fluorescence CT (XFCT) for molecular imaging. , 2015, The British journal of radiology.

[7]  D. Nikolaev,et al.  Monochromatic computed microtomography using laboratory and synchrotron sources and X-ray fluorescence analysis for comprehensive analysis of structural changes in bones1 , 2015, Journal of Applied Crystallography.

[8]  Tracy Vargo-Gogola,et al.  Gold nanoparticles as contrast agents in x-ray imaging and computed tomography. , 2015, Nanomedicine.

[9]  Santo Gammino,et al.  Macro and micro full field x-ray fluorescence with an X-ray pinhole camera presenting high energy and high spatial resolution. , 2014, Analytical chemistry.

[10]  T. Xiao,et al.  X-ray fluorescence computed tomography with absorption correction for biomedical samples , 2014 .

[11]  Lei Xing,et al.  L-shell x-ray fluorescence computed tomography (XFCT) imaging of Cisplatin , 2014, Physics in medicine and biology.

[12]  Christoph Hoeschen,et al.  Molecular imaging based on x-ray fluorescent high-Z tracers , 2013, Physics in medicine and biology.

[13]  Nivedh Manohar,et al.  Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source. , 2013, Medical physics.

[14]  Tetsuya Yuasa,et al.  The feasibility study on 3-dimensional fluorescent x-ray computed tomography using the pinhole effect for biomedical applications , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[15]  J. Habraken,et al.  Contrast-noise-ratio (CNR) analysis and optimisation of breast-specific gamma imaging (BSGI) acquisition protocols , 2013, EJNMMI Research.

[16]  B. Jones,et al.  Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams , 2012, Physics in medicine and biology.

[17]  Nan Li,et al.  X-Ray Fluorescence Emission Tomography (XFET) With Novel Imaging Geometries— A Monte Carlo Study , 2011, IEEE Transactions on Nuclear Science.

[18]  Deng Biao,et al.  First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline , 2011 .

[19]  F. Liu,et al.  X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays , 2010, Physics in medicine and biology.

[20]  F Verhaegen,et al.  SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes , 2009, Physics in medicine and biology.

[21]  Tetsuya Yuasa,et al.  Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition , 1997 .

[22]  Z. Xu,et al.  X-ray fluorescence imaging of metals and metalloids in biological systems. , 2018, American journal of nuclear medicine and molecular imaging.