Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes

This work describes a diffusion‐weighted (DW) interleaved echo‐planar imaging (IEPI) method for use on either conventional whole‐body scanners or scanners equipped with highspeed gradient and receiver hardware. In combination with cardiac gating and motion correction with a pair of orthogonal navigator echoes, the presented method is time‐efficient, compensates for patient motions, and is less sensitive to image distortions than single‐shot methods. The motion‐correction scheme consists of correction for constant and linear phase terms found from the orthogonal navigator echoes. The correction for the linear phase term in the phase‐encode direction includes gridding the data to the Cartesian grid. The DW IEPI was used to image a phantom rotating about the slice‐select direction, and motion correction was performed to eliminate ghost artifacts arising from motion in either the readout‐ or phase‐encoding directions. DW IEPI with motion correction was performed on a normal volunteer and on a patient with a 26‐day‐old region of ischemia over much of the right hemisphere.

[1]  J. D. O'Sullivan,et al.  A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer Tomography , 1985, IEEE Transactions on Medical Imaging.

[2]  P. Grenier,et al.  MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. , 1986, Radiology.

[3]  G A Holland,et al.  Fat suppression by section-select gradient reversal on spin-echo MR imaging. Work in progress. , 1988, Radiology.

[4]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[5]  Robert Turner,et al.  Single-shot diffusion imaging at 2.0 tesla , 1990 .

[6]  S. Riederer,et al.  Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging , 1990, Magnetic resonance in medicine.

[7]  J. Kucharczyk,et al.  Early detection of regional cerebral ischemia in cats: Comparison of diffusion‐ and T2‐weighted MRI and spectroscopy , 1990, Magnetic resonance in medicine.

[8]  J. Kucharczyk,et al.  Ischemic brain damage: reduction by sodium-calcium ion channel modulator RS-87476. , 1991, Radiology.

[9]  J. Pekar,et al.  Imaging of diffusion and microcirculation with gradient sensitization: Design, strategy, and significance , 1991, Journal of magnetic resonance imaging : JMRI.

[10]  R A Knight,et al.  Temporal evolution of ischemic damage in rat brain measured by proton nuclear magnetic resonance imaging. , 1991, Stroke.

[11]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[12]  G. Mckinnon Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner , 1993, Magnetic resonance in medicine.

[13]  C. Sotak,et al.  Diffusion and Perfusion Magnetic Resonance Imaging Studies to Evaluate a Noncompetitive N‐Methyl‐D‐aspartate Antagonist and Reperfusion in Experimental Stroke in Rats , 1993, Stroke.

[14]  J. Felmlee,et al.  Echo-planar imaging of the liver with a standard MR imaging system. , 1993, Radiology.

[15]  R. Ordidge,et al.  Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. , 1994, Magnetic resonance imaging.

[16]  J C Gore,et al.  Analysis and correction of motion artifacts in diffusion weighted imaging , 1994, Magnetic resonance in medicine.

[17]  R M Weisskoff,et al.  MRI signal void due to in‐plane motion is all‐or‐none , 1994, Magnetic resonance in medicine.

[18]  D. Nishimura,et al.  Fast Three Dimensional Magnetic Resonance Imaging , 1995, Magnetic resonance in medicine.

[19]  B. Siewert,et al.  Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging , 1995, Annals of neurology.

[20]  A. D. de Crespigny,et al.  Navigated Diffusion Imaging of Normal and Ischemic Human Brain , 1995, Magnetic resonance in medicine.

[21]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.