Prediction of contact mechanics in metal-on-metal Total Hip Replacement for parametrically comprehensive designs and loads.

Manufacturers and investigators of Total Hip Replacement (THR) bearings require tools to predict the contact mechanics resulting from diverse design and loading parameters. This study provides contact mechanics solutions for metal-on-metal (MoM) bearings that encompass the current design space and could aid pre-clinical design optimization and evaluation. Stochastic finite element (FE) simulation was used to calculate the head-on-cup contact mechanics for five thousand combinations of design and loading parameters. FE results were used to train a Random Forest (RF) surrogate model to rapidly predict the contact patch dimensions, contact area, pressures and plastic deformations for arbitrary designs and loading. In addition to widely observed polar and edge contact, FE results included ring-polar, asymmetric-polar, and transitional categories which have previously received limited attention. Combinations of design and load parameters associated with each contact category were identified. Polar contact pressures were predicted in the range of 0-200 MPa with no permanent deformation. Edge loading (with subluxation) was associated with pressures greater than 500 MPa and induced permanent deformation in 83% of cases. Transitional-edge contact (with little subluxation) was associated with intermediate pressures and permanent deformation in most cases, indicating that, even with ideal anatomical alignment, bearings may face extreme wear challenges. Surrogate models were able to accurately predict contact mechanics 18,000 times faster than FE analyses. The developed surrogate models enable rapid prediction of MoM bearing contact mechanics across the most comprehensive range of loading and designs to date, and may be useful to those performing bearing design optimization or evaluation.

[1]  J. Shelton,et al.  Influence of cup orientation on the wear performance of metal-on-metal hip replacements , 2009, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  Raphael T Haftka,et al.  Surrogate articular contact models for computationally efficient multibody dynamic simulations. , 2010, Medical engineering & physics.

[3]  J Fisher,et al.  A New Formulation for the Prediction of Polyethylene Wear in Artificial Hip Joints , 2011, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[4]  L. E. Goodman,et al.  The contact stress problem for an elastic sphere indenting an elastic cavity , 1965 .

[5]  J Fisher,et al.  Development of computational wear simulation of metal-on-metal hip resurfacing replacements. , 2008, Journal of biomechanics.

[6]  T. Brown,et al.  Do Obesity and/or Stripe Wear Increase Ceramic Liner Fracture Risk? An XFEM Analysis , 2013, Clinical orthopaedics and related research.

[7]  A. Rothwell,et al.  A multinational assessment of metal-on-metal bearings in hip replacement. , 2011, The Journal of bone and joint surgery. American volume.

[8]  I. Clarke,et al.  Surface damage after multiple dislocations of a 38-mm-diameter, metal-on-metal hip prosthesis. , 2008, The Journal of arthroplasty.

[9]  Z. Jin,et al.  Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing , 2003, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  T. Brown,et al.  A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty. , 1996, Journal of biomechanics.

[11]  Mark Taylor,et al.  Computationally efficient prediction of bone-implant interface micromotion of a cementless tibial tray during gait. , 2014, Journal of biomechanics.

[12]  Gabriel Abba,et al.  Approximate Analytical Model for Hertzian Elliptical Contact Problems , 2006 .

[13]  Zhongmin Jin,et al.  Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses. , 2011, The Journal of arthroplasty.

[14]  F. Cosmi,et al.  A finite element method comparison of wear in two metal-on-metal total hip prostheses , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[15]  Dichen Li,et al.  Contact mechanics studies of an ellipsoidal contact bearing surface of metal-on-metal hip prostheses under micro-lateralization. , 2014, Medical engineering & physics.

[16]  Z. Jin,et al.  Contact mechanics analysis of metal-on-metal hip resurfacing prostheses , 2004, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[17]  T. Glant,et al.  Osteolysis: basic science. , 2001, Clinical orthopaedics and related research.

[18]  A Yew,et al.  Analysis of contact mechanics in McKee-Farrar metal-on-metal hip implants , 2003, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[19]  T. Brown,et al.  Edge‐loading severity as a function of cup lip radius in metal‐on‐metal total hips—A finite element analysis , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  B. Springer,et al.  Reduced Articular Surface of One-piece Cups: A Cause of Runaway Wear and Early Failure , 2010, Clinical orthopaedics and related research.

[21]  R. Brannon,et al.  Assessment of the applicability of the Hertzian contact theory to edge-loaded prosthetic hip bearings. , 2011, Journal of biomechanics.

[22]  Z. Jin,et al.  Analysis of elastohydrodynamic lubrication in a novel metal-on-metal hip joint replacement , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  P. Rullkoetter,et al.  Finite element simulation of early creep and wear in total hip arthroplasty. , 2005, Journal of biomechanics.

[24]  J. Fisher,et al.  Effect of cup abduction angle and head lateral microseparation on contact stresses in ceramic-on-ceramic total hip arthroplasty. , 2012, Journal of biomechanics.

[25]  J. Fisher,et al.  Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions , 2012, Journal of biomedical materials research. Part B, Applied biomaterials.

[26]  Zhongmin Jin,et al.  Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface. , 2010, Journal of biomechanics.

[27]  Paulo R Fernandes,et al.  Computational hip joint simulator for wear and heat generation. , 2007, Journal of biomechanics.

[28]  Nathalie Villa-Vialaneix,et al.  A comparison of eight metamodeling techniques for the simulation of N2O fluxes and N leaching from corn crops , 2012, Environ. Model. Softw..

[29]  D. Howie,et al.  The long-term wear of retrieved McKee-Farrar metal-on-metal total hip prostheses. , 2005, The Journal of arthroplasty.

[30]  F. Kennedy,et al.  Gouge features on metal-on-metal hip bearings can result from high stresses during rim contact , 2013 .

[31]  John J Callaghan,et al.  2009 Nicolas Andry Award: Clinical Biomechanics of Third Body Acceleration of Total Hip Wear , 2009, Clinical orthopaedics and related research.

[32]  P. Campbell,et al.  Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. , 2008, The Journal of bone and joint surgery. British volume.

[33]  E. Ebramzadeh,et al.  Contact Patch to Rim Distance Predicts Metal Ion Levels in Hip Resurfacing , 2013, Clinical orthopaedics and related research.

[34]  M. Paley,et al.  Metal-on-Metal Hip Prostheses and Systemic Health: A Cross-Sectional Association Study 8 Years after Implantation , 2013, PloS one.

[35]  G. Niebur,et al.  Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. , 2004, Journal of biomechanics.

[36]  Z. Jin,et al.  Contact mechanics of a novel metal-on-metal total hip replacement , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[37]  Claire L. Brockett,et al.  The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements , 2008, Journal of materials science. Materials in medicine.