Experimental performance evaluation of aerogel glazing systems

Energy savings for heating, air conditioning and illuminating plants could be improved by innovative Transparent Insulation Materials (TIMs), which aim to optimize two opposite requirements: transparency and thermal insulation. Aerogel is one of the most promising materials for use in highly energy-efficient windows: in addition to the low thermal conductivity (down to 0.010W/(mK) in evacuated conditions), a high solar energy and daylight transmittance is achieved. Eight samples were manufactured, by assembling several types of glass with monolithic and granular aerogel in the interspace. U-values slightly higher than 1W/m2K were obtained for all the samples. The monolithic aerogel introduced a better light transmittance (τv=0.60) than granular one (τv=0.27), while U-values were comparable in non-evacuated conditions. With respect to a conventional window (double glazing with a low-e layer), 55% reduction in heat losses was achieved by monolithic aerogel, with only a 25% reduction in light transmittance; for the granular systems, the reduction was about 25% in heat losses, but 66% in light transmission. In order to evaluate the aerogel employing in buildings, a prototype of an aluminum frame window with granular aerogel in interspace was realized. Thermal and acoustic properties of the prototype were evaluated according to the standards. The thermal transmittance of the innovative glazing system was little lower than 1W/(m2K) and it showed also good acoustic properties: the Rw index was 3dB higher than the one of a conventional window with air in interspace.

[1]  Ann M. Anderson,et al.  Silica aerogels prepared via rapid supercritical extraction: Effect of process variables on aerogel properties , 2009 .

[2]  C. Buratti Transparent Insulating Materials: Experimental Data And BuildingsEnergy Saving Evaluation , 1970 .

[3]  Svend Svendsen,et al.  Monolithic silica aerogel in superinsulating glazings , 1998 .

[4]  Yu.K. Akimov,et al.  Fields of Application of Aerogels (Review) , 2003 .

[5]  Giorgio Baldinelli,et al.  Thermal transmittance measurements with the hot box method: Calibration, experimental procedures, an , 2011 .

[6]  J. Fricke,et al.  Silica aerogel granulate material for thermal insulation and daylighting , 2005 .

[7]  Arild Gustavsen,et al.  Aerogel insulation for building applications: A state-of-the-art review , 2011 .

[8]  Nathan Mendes,et al.  Capacitive effect on the heat transfer through building glazing systems , 2011 .

[9]  M. Einarsrud,et al.  Improvement of the silica aerogel strengthening process for scaling-up monolithic tile production , 2004 .

[10]  K. Igarashi,et al.  The effect of the preparation conditions on the optical properties of transparent silica aerogels , 1998 .

[11]  M. Glora,et al.  Highly insulating aerogel glazing for solar energy usage , 2002 .

[12]  Cinzia Buratti,et al.  Development of Innovative Heating and Cooling Systems Using Renewable Energy Sources for Non-Residential Buildings , 2013 .

[13]  Jørgen Munthe Schultz,et al.  Evacuated aerogel glazings , 2008 .

[14]  Finn Harken Kristiansen,et al.  Super insulating aerogel glazing , 2005 .

[15]  Finn Harken Kristiansen,et al.  Development of windows based on highly insulating aerogel glazings , 2004 .

[16]  Alpin Köknel Yener,et al.  Building envelope design with the objective to ensure thermal, visual and acoustic comfort conditions , 2004 .

[17]  Patrick James,et al.  Potential of emerging glazing technologies for highly glazed buildings in hot arid climates , 2008 .

[18]  A. Beck,et al.  Silica-aerogel granulate – Structural, optical and thermal properties , 2004 .

[19]  Giorgio Baldinelli,et al.  COMPARATIVE ANALYSIS OF DIFFERENT METHODS TO EVALUATE THE THERMAL CONDUCTIVITY OF HOMOGENOUS MATERIALS , 2010 .