Design of a high-bandwidth tripod scanner for high speed atomic force microscopy.

Tip-scanning high-speed atomic force microscopes (HS-AFMs) have several advantages over their sample-scanning counterparts. Firstly, they can be used on samples of almost arbitrary size since the high imaging bandwidth of the system is immune to the added mass of the sample and its holder. Depending on their layouts, they also enable the use of several tip-scanning HS-AFMs in combination. However, the need for tracking the cantilever with the readout laser makes designing tip-scanning HS-AFMs difficult. This often results in a reduced resonance frequency of the HS-AFM scanner, or a complex and large set of precision flexures. Here, we present a compact, simple HS-AFM designed for integrating the self-sensing cantilever into the tip-scanning configuration, so that the difficulty of tracking small cantilever by laser beam is avoided. The position of cantilever is placed to the end of whole structure, hence making the optical viewing of the cantilever possible. As the core component of proposed system, a high bandwidth tripod scanner is designed, with a scan size of 5.8 µm × 5.8 µm and a vertical travel range of 5.9 µm. The hysteresis of the piezoactuators in X- and Y-axes are linearized using input shaping technique. To reduce in-plane crosstalk and vibration-related dynamics, we implement both filters and compensators on a field programmable analog array. Based on these, images with 512 × 256 pixels are successfully obtained at scan rates up to 1024 lines/s, corresponding to a 4 mm/stip velocity. SCANNING 38:889-900, 2016. © 2016 Wiley Periodicals, Inc.

[1]  Georg E. Fantner,et al.  Studying biological membranes with extended range high-speed atomic force microscopy , 2015, Scientific Reports.

[2]  S O R Moheimani,et al.  Invited review article: high-speed flexure-guided nanopositioning: mechanical design and control issues. , 2012, The Review of scientific instruments.

[3]  Andrew J Fleming A megahertz bandwidth dual amplifier for driving piezoelectric actuators and other highly capacitive loads. , 2009, The Review of scientific instruments.

[4]  Yuen Kuan Yong,et al.  Design, Modeling, and FPAA-Based Control of a High-Speed Atomic Force Microscope Nanopositioner , 2013, IEEE/ASME Transactions on Mechatronics.

[5]  Julius Joseph Santillan,et al.  In situ Characterization of Photoresist Dissolution , 2010 .

[6]  Paul K. Hansma,et al.  Design and input-shaping control of a novel scanner for high-speed atomic force microscopy , 2008 .

[7]  Blake W Erickson,et al.  Harnessing the damping properties of materials for high-speed atomic force microscopy. , 2016, Nature nanotechnology.

[8]  Toshio Ando,et al.  Wide-area scanner for high-speed atomic force microscopy. , 2013, The Review of scientific instruments.

[9]  Jonathan D. Adams,et al.  Components for high speed atomic force microscopy. , 2006, Ultramicroscopy.

[10]  Henning Stahlberg,et al.  Characterization of the motion of membrane proteins using high-speed atomic force microscopy. , 2012, Nature nanotechnology.

[11]  Paul K. Hansma,et al.  Tapping mode atomic force microscopy in liquids , 1994 .

[12]  A. Fleming,et al.  Evaluation of charge drives for scanning probe microscope positioning stages , 2008, 2008 American Control Conference.

[13]  S O R Moheimani,et al.  High-speed cycloid-scan atomic force microscopy , 2010, Nanotechnology.

[14]  T. Schäffer,et al.  High-speed atomic force microscopy for large scan sizes using small cantilevers , 2010, Nanotechnology.

[15]  Santosh Devasia,et al.  Feedback-Linearized Inverse Feedforward for Creep, Hysteresis, and Vibration Compensation in AFM Piezoactuators , 2007, IEEE Transactions on Control Systems Technology.

[16]  K. Leang,et al.  Design and Control of a Three-Axis Serial-Kinematic High-Bandwidth Nanopositioner , 2012, IEEE/ASME Transactions on Mechatronics.

[17]  Todd Sulchek,et al.  High-speed tapping mode imaging with active Q control for atomic force microscopy , 2000 .

[18]  Stefan Kuiper,et al.  Model-based feedback controller design for dual actuated atomic force microscopy , 2012 .

[19]  J. Lygeros,et al.  High-speed multiresolution scanning probe microscopy based on Lissajous scan trajectories , 2012, Nanotechnology.

[20]  Karl Johan Åström,et al.  Design and Modeling of a High-Speed AFM-Scanner , 2007, IEEE Transactions on Control Systems Technology.

[21]  Georg E. Fantner,et al.  Kinetics of Antimicrobial Peptide Activity Measured on Individual Bacterial Cells Using High Speed AFM , 2010, Nature nanotechnology.

[22]  Toshio Ando,et al.  Video imaging of walking myosin V by high-speed atomic force microscopy , 2010, Nature.

[23]  D. Croft,et al.  Creep, Hysteresis, and Vibration Compensation for Piezoactuators: Atomic Force Microscopy Application , 2001 .

[24]  G. Schitter,et al.  Field Programmable Analog Array (FPAA) based control of an Atomic Force Microscope , 2008, 2008 American Control Conference.

[25]  Georg Schitter,et al.  Data acquisition system for high speed atomic force microscopy , 2005 .

[26]  T. Ando,et al.  High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes , 2008 .

[27]  T. Ando,et al.  Dynamic proportional-integral-differential controller for high-speed atomic force microscopy , 2006 .

[28]  Mervyn J Miles,et al.  A mechanical microscope: High speed atomic force microscopy , 2005 .

[29]  Jacqueline A. Cutroni,et al.  Rigid design of fast scanning probe microscopes using finite element analysis. , 2004, Ultramicroscopy.

[30]  I. A. Mahmood,et al.  Fast spiral-scan atomic force microscopy , 2009, Nanotechnology.

[31]  Takeshi Fukuma,et al.  High resonance frequency force microscope scanner using inertia balance support , 2008 .

[32]  Todd Sulchek,et al.  Characterization and optimization of scan speed for tapping-mode atomic force microscopy , 2002 .