Multichannel transceiver dual-tuned RF coil for proton/sodium MR imaging of knee cartilage at 3 T.

Sodium magnetic resonance (MR) imaging is a promising technique for detecting changes of proteoglycan (PG) content in cartilage associated with knee osteoarthritis. Despite its potential clinical benefit, sodium MR imaging in vivo is challenging because of intrinsically low sodium concentration and low MR signal sensitivity. Some of the challenges in sodium MR imaging may be eliminated by the use of a high-sensitivity radiofrequency (RF) coil, specifically, a dual-tuned (DT) proton/sodium RF coil which facilitates the co-registration of sodium and proton MR images and the evaluation of both physiochemical and structural properties of knee cartilage. Nevertheless, implementation of a DT proton/sodium RF coil is technically difficult because of the coupling effect between the coil elements (particularly at high field) and the required compact design with improved coil sensitivity. In this study, we applied a multitransceiver RF coil design to develop a DT proton/sodium coil for knee cartilage imaging at 3 T. With the new design, the size of the coil was minimized, and a high signal-to-noise ratio (SNR) was achieved. DT coil exhibited high levels of reflection S11 (∼-21 dB) and transmission coefficient S12 (∼-19 dB) for both the proton and sodium coils. High SNR (range 27-38) and contrast-to-noise ratio (CNR) (range 15-21) were achieved in sodium MR imaging of knee cartilage in vivo at 3-mm(3) isotropic resolution. This DT coil performance was comparable to that measured using a sodium-only birdcage coil (SNR of 28 and CNR of 20). Clinical evaluation of the DT coil on four normal subjects demonstrated a consistent acquisition of high-resolution proton images and measurement of relative sodium concentrations of knee cartilages without repositioning of the subjects during the same MR scanning session.

[1]  D. Burstein,et al.  Gd‐DTPA2− as a measure of cartilage degradation , 1996, Magnetic resonance in medicine.

[2]  K. Thulborn,et al.  Experimentally verified, theoretical design of dual‐tuned, low‐pass birdcage radiofrequency resonators for magnetic resonance imaging and magnetic resonance spectroscopy of human brain at 3.0 Tesla , 1999, Magnetic resonance in medicine.

[3]  Alexej Jerschow,et al.  Sodium inversion recovery MRI of the knee joint in vivo at 7T. , 2010, Journal of magnetic resonance.

[4]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[5]  Deborah Burstein,et al.  MRI for development of disease‐modifying osteoarthritis drugs , 2006, NMR in biomedicine.

[6]  Bing Wu,et al.  7T Human Spine Imaging Arrays With Adjustable Inductive Decoupling , 2010, IEEE Transactions on Biomedical Engineering.

[7]  Andrew Webb,et al.  Design of a capacitively decoupled transmit/receive NMR phased array for high field microscopy at 14.1T. , 2004, Journal of magnetic resonance.

[8]  J. B. Kneeland,et al.  Sodium MRI of human articular cartilage in vivo , 1998, Magnetic resonance in medicine.

[9]  M Alecci,et al.  Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties , 2001, Magnetic resonance in medicine.

[10]  E. J. Wilkinson An N-Way Hybrid Power Divider , 1960 .

[11]  H. Imhof,et al.  Magnetic Resonance Imaging of Articular Cartilage and Evaluation of Cartilage Disease , 2000, Investigative radiology.

[12]  David T Felson,et al.  An update on the pathogenesis and epidemiology of osteoarthritis. , 2004, Radiologic clinics of North America.

[13]  L. Wald,et al.  Eight‐channel phased array coil and detunable TEM volume coil for 7 T brain imaging , 2005, Magnetic resonance in medicine.

[14]  G. Bruce Pike,et al.  Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI , 1998, IEEE Transactions on Medical Imaging.

[15]  Xiaoliang Zhang,et al.  Design of an inductively decoupled microstrip array at 9.4 T. , 2006, Journal of magnetic resonance.

[16]  Michael Bock,et al.  3D radial projection technique with ultrashort echo times for sodium MRI: Clinical applications in human brain and skeletal muscle , 2007, Magnetic resonance in medicine.

[17]  R. Regatte,et al.  Clean demarcation of cartilage tissue 23Na by inversion recovery. , 2008, Journal of magnetic resonance.

[18]  M Alecci,et al.  Practical design of a 4 Tesla double-tuned RF surface coil for interleaved 1H and 23Na MRI of rat brain. , 2006, Journal of magnetic resonance.

[19]  Peter Börnert,et al.  Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling , 2006, Magnetic resonance in medicine.

[20]  Jian Xu,et al.  Rapid 3D‐T1ρ mapping of the knee joint at 3.0T with parallel imaging , 2006, Magnetic resonance in medicine.

[21]  Gregory Chang,et al.  Rapid isotropic 3D‐sodium MRI of the knee joint in vivo at 7T , 2009, Journal of magnetic resonance imaging : JMRI.

[22]  Andrew J Wheaton,et al.  Proteoglycan loss in human knee cartilage: quantitation with sodium MR imaging--feasibility study. , 2004, Radiology.

[23]  K. Thulborn,et al.  Spectrally weighted twisted projection imaging: Reducing T2 signal attenuation effects in fast three‐dimensional sodium imaging , 1997, Magnetic resonance in medicine.

[24]  Lothar R. Schad,et al.  ECG-gated 23Na-MRI of the human heart using a 3D-radial projection technique with ultra-short echo times , 2004, Magnetic Resonance Materials in Physics, Biology and Medicine.

[25]  Ray F. Lee,et al.  Coupling and decoupling theory and its application to the MRI phased array , 2002, Magnetic resonance in medicine.

[26]  D. Burstein,et al.  MRI Techniques in Early Stages of Cartilage Disease , 2000, Investigative radiology.

[27]  Michael B. Smith,et al.  Exploring the limits of RF shimming for high‐field MRI of the human head , 2006, Magnetic resonance in medicine.

[28]  S. Neubauer,et al.  Sodium T2* relaxation times in human heart muscle , 2002, Journal of magnetic resonance imaging : JMRI.

[29]  Ravinder R Regatte,et al.  Rapid 3D‐T1 mapping of cartilage with variable flip angle and parallel imaging at 3.0T , 2008, Journal of magnetic resonance imaging : JMRI.

[30]  Arijitt Borthakur,et al.  Sodium and T1ρ MRI for molecular and diagnostic imaging of articular cartilage , 2006, NMR in biomedicine.

[31]  K. Uğurbil,et al.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging , 2005, Magnetic resonance in medicine.

[32]  R. Wilkins,et al.  The cellular physiology of articular cartilage , 1996, Experimental physiology.

[33]  Steen Moeller,et al.  B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil , 2005, Magnetic resonance in medicine.

[34]  S. Trattnig,et al.  Anatomy, Biochemistry, and Physiology of Articular Cartilage , 2000, Investigative radiology.

[35]  Jianming Jin Electromagnetic Analysis and Design in Magnetic Resonance Imaging , 1998 .

[36]  A. Zaninelli,et al.  Osteoarthritis: an overview of the disease and its treatment strategies. , 2005, Seminars in arthritis and rheumatism.

[37]  K. Uğurbil,et al.  Different excitation and reception distributions with a single‐loop transmit‐receive surface coil near a head‐sized spherical phantom at 300 MHz , 2002, Magnetic resonance in medicine.