Membrane-activated microfluidic rotary devices for pumping and mixing

Microfluidic devices are operated at a low-Reynolds-number flow regime such that the transportation and mixing of fluids are naturally challenging. There is still a great need to integrate fluid control systems such as pumps, valves and mixers with other functional microfluidic devices to form a micro-total-analysis-system. This study presents a new pneumatic microfluidic rotary device capable of transporting and mixing two different kinds of samples in an annular microchannel by using MEMS (Micro-electro-mechanical-systems) technology. Pumping and mixing can be achieved using a single device with different operation modes. The micropump has four membranes with an annular layout and is compact in size. The new device has a maximum pumping rate of 165.7 μL/min at a driving frequency of 17 Hz and an air pressure of 30 psi. Experimental data show that the pumping rate increases as higher air pressure and driving frequency are applied. In addition, not only can the microfluidic rotary device work as a peristaltic pumping device, but it also is an effective mixing device. The performance of the micromixer is extensively characterized. Experimental data indicate that a mixing index as high as 96.3% can be achieved. The developed microfluidic rotary device can be easily integrated with other microfluidic devices due to its simple and reliable PDMS fabrication process. The development of the microfluidic rotary device can be promising for micro-total-analysis-systems.

[1]  Stephen R. Quake,et al.  A Microfabricated Rotary Pump , 2001 .

[2]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[3]  N. Kasagi,et al.  A chaotic mixer for magnetic bead-based micro cell sorter , 2004, Journal of Microelectromechanical Systems.

[4]  Gwo-Bin Lee,et al.  Pneumatic micropumps with serially connected actuation chambers , 2006 .

[5]  A. Yamazaki,et al.  Fabrication of micropump with spiral-type magnetic micro-machine , 2003, Digest of INTERMAG 2003. International Magnetics Conference (Cat. No.03CH37401).

[6]  N. Lobontiu Mechanics of microelectromechanical systems , 2004 .

[7]  Ming Lei,et al.  Hard and soft micromachining for BioMEMS: review of techniques and examples of applications in microfluidics and drug delivery. , 2004, Advanced drug delivery reviews.

[8]  Masayoshi Esashi,et al.  Micro instrumentation for characterizing thermoelectric properties of nanomaterials , 2005 .

[9]  Hengzi Wang,et al.  Optimizing layout of obstacles for enhanced mixing in microchannels , 2002 .

[10]  Joe T. Lin,et al.  Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays , 1999 .

[11]  V. Hessel,et al.  Laminar mixing in different interdigital micromixers: I. Experimental characterization , 2003 .

[12]  Toshiyuki Hayase,et al.  Three-dimensional analysis of swimming properties of a spiral-type magnetic micro-machine , 2003 .

[13]  Juan G. Santiago,et al.  Fabrication and characterization of electroosmotic micropumps , 2001 .

[14]  K. R. Williams,et al.  Novel interconnection technologies for integrated microfluidic systems , 1998 .

[15]  Liwei Lin,et al.  Active microfluidic mixer and gas bubble filter driven by thermal bubble micropump , 2002 .

[16]  Steffen Hardt,et al.  Laminar mixing in different interdigital micromixers: II. Numerical simulations , 2003 .

[17]  Tianning Chen,et al.  Simulation and optimization of chaotic micromixer using lattice Boltzmann method , 2005 .

[18]  G. Whitesides,et al.  Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies , 2003, Electrophoresis.

[19]  Mansun Chan,et al.  A DNA-detection platform with integrated photodiodes on a silicon chip , 2005 .

[20]  Gwo-Bin Lee,et al.  Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection. , 2005, Biosensors & bioelectronics.

[21]  Nadine Aubry,et al.  Enhancement of microfluidic mixing using time pulsing. , 2003, Lab on a chip.

[22]  Paul Yager,et al.  Simple quantitative optical method for monitoring the extent of mixing applied to a novel microfluidic mixer , 2004 .

[23]  Jung Kyung Kim,et al.  Rapid three-dimensional passive rotation micromixer using the breakup process , 2004 .

[24]  H. Goto,et al.  Active micromixer for microfluidic systems using lead‐zirconate‐titanate(PZT)‐generated ultrasonic vibration , 2000, Electrophoresis.

[25]  Nam-Trung Nguyen,et al.  Micromixers?a review , 2005 .

[26]  I. Mezić,et al.  Chaotic Mixer for Microchannels , 2002, Science.

[27]  Helen Song,et al.  Experimental test of scaling of mixing by chaotic advection in droplets moving through microfluidic channels. , 2003, Applied physics letters.

[28]  Gwo-Bin Lee,et al.  Electrokinetically driven active micro-mixers utilizing zeta potential variation induced by field effect , 2004 .

[29]  Alan G. R. Evans,et al.  Two simple micromixers based on silicon , 1998 .

[30]  Alan G. R. Evans,et al.  Investigation for the operation of an integrated peristaltic micropump , 2004 .

[31]  Jens Anders Branebjerg,et al.  Microfluidics-a review , 1993 .

[32]  Stephen Quake,et al.  A nanoliter rotary device for polymerase chain reaction , 2002, Electrophoresis.

[33]  Ruey-Jen Yang,et al.  Computational analysis of electrokinetically driven flow mixing in microchannels with patterned blocks , 2004 .

[34]  P Hinsmann,et al.  Design, simulation and application of a new micromixing device for time resolved infrared spectroscopy of chemical reactions in solution. , 2001, Lab on a chip.

[35]  S. Quake,et al.  An Integrated Microfabricated Cell Sorter , 2022 .

[36]  Development of a non-contact micro-liquid mixing method and application to chemical auto-analyzers , 2005 .