Estimation of the Utility's and Consumer's Contribution to Harmonic Distortion

A method has been presented for the allocation of responsibilities between a utility and a consumer with reference to the distortion of 3-phase voltage waveforms at the point of common coupling. The input data required for applying this method are the measured voltage and current waveforms at the point of common coupling. The frequencies in the measured waveforms are estimated and a Kalman filter is used to estimate the phasors at these frequencies. Subsequently, the parameters of the electrical system of the industrial load have been estimated using the recursive least-squares technique. With these estimated data, the individual contributions to the distortion of the 3-phase voltage waveforms have been calculated. The proposed method has been illustrated by means of a practical example.

[1]  Adly A. Girgis,et al.  Identification and tracking of harmonic sources in a power system using a Kalman filter , 1996 .

[2]  A. H. Samra,et al.  Identification of harmonic sources in power distribution systems , 1997, Proceedings IEEE SOUTHEASTCON '97. 'Engineering the New Century'.

[3]  K. Srinivasan,et al.  Conforming and non-conforming current for attributing steady state power quality problems , 1998 .

[4]  Y. Liu,et al.  An Investigation on the Validity of Power Direction Method for Harmonic Source Determination , 2002, IEEE Power Engineering Review.

[5]  K. Wilkosz Harmonic Sources Localization: Comparison of methods utilizing the voltage rate or the current rate , 2007, 2007 9th International Conference on Electrical Power Quality and Utilisation.

[6]  K. Wilkosz,et al.  Utilization of the voltage rate to localization of harmonic sources in a power system , 2004, Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521).

[7]  A. E. Emanuel Harmonic cost allocation: a difficult task , 1999, 1999 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.99CH36364).

[8]  Giuseppe Fusco,et al.  Constrained least squares methods for parameter tracking of power system steady-state equivalent circuits , 2000 .

[9]  S.R. Naidu,et al.  A novel technique for estimating harmonic and inter-harmonic frequencies in power system signals , 2005, Proceedings of the 2005 European Conference on Circuit Theory and Design, 2005..

[10]  Shoji Nishimura,et al.  Advanced technology to identify harmonics characteristics and results of measuring , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[11]  M. Neri,et al.  Estimation of the Utility's and Consumer's Contribution to Harmonic Distortion , 2009, IEEE Transactions on Instrumentation and Measurement.

[12]  Yilu Liu,et al.  A method for determining customer and utility harmonic contributions at the point of common coupling , 2000 .

[13]  K. Wilkosz,et al.  Identification of harmonic sources in a power system: A new method , 2005, 2005 IEEE Russia Power Tech.

[14]  Shoji Nishimura,et al.  Advanced method to identify harmonics characteristic between utility grid and harmonic current sources , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[15]  Wilsun Xu,et al.  A "critical impedance"-based method for identifying harmonic sources , 2004, IEEE Transactions on Power Delivery.

[16]  A.A. Moustafa,et al.  Separation of customer and supply harmonics in electrical power distribution systems , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).