Coronary MRA with 3D undersampled projection reconstruction TrueFISP

Undersampled projection reconstruction (PR) offers improved imaging efficiency allowing a relative tradeoff between signal‐to‐noise ratio (SNR) or streak artifact and the number of acquired k‐space views rather than the tradeoff between resolution or aliasing artifact and the number of acquired k‐space lines inherent to Fourier imaging techniques. TrueFISP (true fast imaging with steady state precession) is ideally suited for undersampled PR imaging because of its inherently high SNR. The purpose of this work was to investigate the feasibility of using undersampled three‐dimensional (3D) PR TrueFISP for breathhold coronary artery imaging. Phantom studies and a preliminary in vivo comparison demonstrated the improved spatial resolution of PR over Fourier TrueFISP with the same imaging time. In a 24‐heartbeat coronary imaging scheme, segmented 3D PR TrueFISP provided a 1.0 × 1.0 mm2 isotropic in‐plane voxel size while acquiring between 93 and 153 views per partition. Streak artifacts were present in some images but were not found to impede coronary artery delineation. In conclusion, 3D undersampled PR TrueFISP provides isotropic in‐plane voxel size within a single breathhold and is a promising technique for coronary artery imaging. Magn Reson Med 48:594–601, 2002. © 2002 Wiley‐Liss, Inc.

[1]  J Hennig,et al.  Reduced circular field‐of‐view imaging , 1998, Magnetic resonance in medicine.

[2]  M L Wood,et al.  Gradient moment nulling for steady-state free precession MR imaging of cerebrospinal fluid. , 1991, Medical physics.

[3]  T M Grist,et al.  Single breath‐hold 3D contrast‐enhanced method for assessment of cardiac function , 2000, Magnetic resonance in medicine.

[4]  S. T. Nichols,et al.  Quantitative evaluation of several partial fourier reconstruction algorithms used in mri , 1993, Magnetic resonance in medicine.

[5]  H K Song,et al.  k‐Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI , 2000, Magnetic resonance in medicine.

[6]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[7]  O. Simonetti,et al.  Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. , 2001, Radiology.

[8]  D C Peters,et al.  Phase‐contrast with interleaved undersampled projections , 2000, Magnetic resonance in medicine.

[9]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[10]  Weili Lin,et al.  A fast, iterative, partial-fourier technique capable of local phase recovery , 1991 .

[11]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[12]  D. Peters,et al.  Undersampled projection reconstruction applied to MR angiography , 2000, Magnetic resonance in medicine.

[13]  G Laub,et al.  3D magnetization‐prepared true‐FISP: A new technique for imaging coronary arteries , 2001, Magnetic resonance in medicine.

[14]  J S Lewin,et al.  Segmented k-space and real-time cardiac cine MR imaging with radial trajectories. , 2001, Radiology.

[15]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[16]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[17]  René M. Botnar,et al.  Free‐breathing 3D coronary MRA: The impact of “Isotropic” image resolution , 2000, Journal of magnetic resonance imaging : JMRI.

[18]  V Rasche,et al.  MR fluoroscopy using projection reconstruction multi‐gradient‐echo (prMGE) MRI , 1999, Magnetic resonance in medicine.

[19]  Debiao Li,et al.  Breath‐hold three‐dimensional true‐FISP imaging of coronary arteries using asymmetric sampling , 2002, Journal of magnetic resonance imaging : JMRI.

[20]  J Hennig,et al.  Spiral reconstruction by regridding to a large rectilinear matrix: A practical solution for routine systems , 1999, Journal of magnetic resonance imaging : JMRI.

[21]  D C Peters,et al.  Myocardial wall tagging with undersampled projection reconstruction † , 2001, Magnetic resonance in medicine.

[22]  D. Noll,et al.  Homodyne detection in magnetic resonance imaging. , 1991, IEEE transactions on medical imaging.