Development of a D-STATCOM prototype based on cascade inverter with isolation transformer for unbalanced load compensation

This paper describes the distribution level static compensator (D-STATCOM) of three-phase three-wire distribution system for unbalanced load compensation. First, a novel transformer-isolated multilevel H-bridges inverter is introduced, which is suitable for large unbalanced load compensation. For solution to improve the power quality at the point of common coupling (PCC), the compensation scheme is proposed with dual d-q transformation and symmetrical components method. In addition, the balancing design method is employed to equalize the phase currents of triangle connection transformer. Then the computer simulation system is built with software PSCAD to test the functions of the D-STATCOM. Finally, the hardware prototype is made based on two H-bridges voltage source inverter with 1700 V/75 A IGBT. The switching frequency of the space vector modulation (SVM) PWM is set at 500 Hz to generate the compensation currents. The DSP and FPGA based system is employed as the controller. Simulation and experimental results are also given to validate the effectiveness of the proposed D-STATCOM

[1]  J. Sun,et al.  Voltage flicker mitigation using PWM-based distribution STATCOM , 2002, IEEE Power Engineering Society Summer Meeting,.

[2]  Narain G. Hingorani,et al.  Introducing custom power , 1995 .

[3]  T. Larsson,et al.  STATCOM, an efficient means for flicker mitigation , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).

[4]  Johan Enslin,et al.  Unified approach to power quality mitigation , 1998, IEEE International Symposium on Industrial Electronics. Proceedings. ISIE'98 (Cat. No.98TH8357).

[5]  W. T. Norris,et al.  Flicker analysis and methods for electric arc furnace flicker (EAF) mitigation (a survey) , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[6]  Masatoshi Takeda,et al.  Improved power quality solutions using advanced solid-state switching and static compensation technologies , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).

[7]  Gregory F. Reed,et al.  Application of a 5 MVA, 4.16 kV D-STATCOM system for voltage flicker compensation at Seattle Iron and Metals , 2000, 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134).

[8]  Frede Blaabjerg,et al.  Flicker mitigation of grid connected wind turbines using STATCOM , 2004 .

[9]  Hossein Mokhtari,et al.  Effects of dynamic reactive compensation in arc furnace operation characteristics and its economic benefits , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[10]  Chi-Jui Wu,et al.  On-line reactive power compensation schemes for unbalanced three phase four wire distribution feeders , 1993 .

[11]  L. Gyugyi,et al.  Principles and Applications of Static, Thyristor-Controlled Shunt Compensators , 1978, IEEE Transactions on Power Apparatus and Systems.

[12]  Wei-Neng Chang,et al.  Design and implementation of DSTATCOM with symmetrical components method for fast load compensation of unbalanced distribution systems , 2003, The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003..

[13]  J. E. Hill A practical example of the use of distribution static compensator (D-STATCOM) to reduce voltage fluctuations , 1997 .

[14]  P. Ashmole,et al.  System flicker disturbances from industrial loads and their compensation , 1997 .

[15]  M. Etezadi-Amoli,et al.  An improved modeling technique for distribution feeders with incomplete information , 1993 .