High Repetition Rate Space Charge Measurement of Heat-treated Low-density Polyethylene at Prebreakdown

Prebreakdown is a transient process and the external electric field at prebreakdown is widely used to evaluate dielectric performance of polymeric materials without considering space charge effects. In this study, a 1-ms high repetition rate pulsed electro-acoustic (PEA) system was developed to observe space charge evolution in heat-treated low-density polyethylene (LDPE) films at prebreakdown under a linear ramping voltage of 1.5 kV/s at 70°C. The continuous recording time was 30 s. The results show that the maximum internal field, which was nonlinear with the linear ramping voltage, of heat-treated LDPE films at prebreakdown is similar. Before prebreakdown, ice-water cooling LDPE films appeared multiple positive space charge packets and alternately migrated towards the cathode, while air cooling and slow cooling LDPE films existed a large number of negative charge injection, migration, and accumulation. At prebreakdown, the maximum field distortion ratio of all heat-treated LDPE films exceeded 40% due to space charge accumulation, which could provide new ideas and data support for evaluating the breakdown characteristics of insulating materials considering space charge effects.

[1]  Yunxiao Zhang,et al.  Transient dynamics of packet-like space charge in low-density polyethylene at high temperatures , 2017 .

[2]  Yuanxiang Zhou,et al.  Transient Behavior of Space Charge in Heat-Treated Low-Density Polyethylene under Coupled Fields , 2017 .

[3]  Wen-Wei Shen,et al.  Identification of electron and hole trap based on isothermal surface potential decay model , 2013 .

[4]  T. Lewis,et al.  The contribution of field-induced morphological change to the electrical aging and breakdown of polyethylene , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[5]  T. Maeno,et al.  Space charge behavior in low density polyethylene at pre-breakdown , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  K. Fukunaga,et al.  High repetition rate PEA system for in-situ space charge measurement during breakdown tests , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  Z. Guan,et al.  Annealing effect on DC conduction in polyethylene films , 2003 .

[8]  T. Maeno,et al.  Space charge dynamics in LDPE films immediately before breakdown , 2001 .

[9]  Naohiro Hozumi,et al.  Space charge distribution measured with short period interval up to electrical breakdown in polyethylene , 1999, 1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319).

[10]  Sandro Scandolo,et al.  Interchain states and the negative electron affinity of polyethylene , 1998, 1998 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.98CH36257).

[11]  M. Ieda Electrical Conduction and Carrier Traps in Polymeric Materials , 1983, IEEE Transactions on Electrical Insulation.