Indoor Climate and the Performance of Ventilation in Finnish Residences

The purpose of the study was to gather information about the actual ventilation and indoor air quality and to evaluate the differences between houses and apartments with different ventilation systems. A sample of 242 dwellings in the Helsinki metropolitan area was studied over periods of no weeks during the 1988-1989 heating season. The mean air-exchange rates had a high variation (average 0.52 l/h, range 0.07-1.55 l/h). The ASHRAE minimum value of 0.35 l/h was not achieved in 28% of the dwellings. The air-exchange rates were significantly her in the houses than in the apartments (averages 0.45/0.64 l/h, p < 0.001); in the natural ventilation systems they, were slightly her than in the mechanical systems. The average temperature in the bedrooms was approximately 22 °C (range 18–27 °C), slightly but significantly higher in the apartment than in the houses. The average dust depositions were higher in the balanced ventilation systems than in the other systems. The median radon concentration was 82 Bq/m3 (range 5-866 Bq/m3); the Finnish target value of 200 Bq/m3 was exceeded in 17% of the houses but in none of the apartment. The measurements indicate that the indoor air quality in Finnish dwellings is not always satisfactory with reference to human health and comfort.

[1]  Olli Seppänen,et al.  Indoor air quality requirements for healthy office buildings: Recommendations based on an epidemiologic study , 1991 .

[2]  P S Burge,et al.  Building sickness, are symptoms related to the office lighting? , 1989, The Annals of occupational hygiene.

[3]  O. Axelson,et al.  Radon in homes--a possible cause of lung cancer. , 1984, Scandinavian journal of work, environment & health.

[4]  O. Axelson,et al.  Indoor radon exposure and active and passive smoking in relation to the occurrence of lung cancer. , 1988, Scandinavian journal of work, environment & health.

[5]  G. Eklund,et al.  Indoor exposure to radon from the ground and bronchial cancer in women , 1987, International archives of occupational and environmental health.

[6]  Olli Seppänen,et al.  Sick building syndrome, sensation of dryness and thermal comfort in relation to room temperature in an office building: Need for individual control of temperature , 1989 .

[7]  A. Smith,et al.  Consistent pattern of elevated symptoms in air-conditioned office buildings: a reanalysis of epidemiologic studies. , 1990, American journal of public health.

[8]  C Edling,et al.  Lung cancer and residency--a case-referent study on the possible impact of of exposure to radon and its daughters in dwellings. , 1979, Scandinavian journal of work, environment & health.

[9]  L. Damber,et al.  Lung cancer in males and type of dwelling. An epidemiologic pilot study. , 1987, Acta oncologica.

[10]  D. Norbäck,et al.  Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools. , 1990, British journal of industrial medicine.

[11]  C A Pickering,et al.  The sick building syndrome: prevalence studies. , 1984, British medical journal.

[12]  Olli Seppänen,et al.  Symptoms and Perceived Indoor Air Quality among Occupants of Houses and Apartments with Different Ventilation Systems , 1991 .

[13]  A Hedge,et al.  Comparison of health problems related to work and environmental measurements in two office buildings with different ventilation systems. , 1985, British medical journal.

[14]  I. Mäkeläinen,et al.  Studies of high indoor radon areas in Finland. , 1985, The Science of the total environment.

[15]  A Hedge,et al.  Sick building syndrome: a study of 4373 office workers. , 1987, The Annals of occupational hygiene.

[16]  Alan Hedge,et al.  Work-related illness in offices: A proposed model of the “sick building syndrome” , 1989 .