Trifocal versus Bifocal Diffractive Intraocular Lens Implantation after Cataract Surgery or Refractive Lens Exchange: a Meta-analysis

Background We compared the efficacy between trifocal and bifocal diffractive intraocular lens (IOL) implantation. Methods Through PubMed, MEDLINE, EMBASE, and CENTRAL, we searched potentially relevant articles published from 1990 to 2018. Defocus curves, visual acuities (VAs) were measured as primary outcomes. Spectacle dependence, postoperative refraction, contrast sensitivity (CS), glare, and higher-order aberrations (HOAs) were measured as secondary outcomes. Effects were pooled using random-effects method. Results We included 11 clinical trials, with a total of 787 eyes (395 subjects). The trifocal IOL group showed better binocular distance VA corrected with defocus levels of −0.5, −1.0, −1.5, and −2.5 diopter than the bifocal IOL group (All P ≤ 0.004). The trifocal IOL group showed better monocular uncorrected distance and intermediate VAs (mean difference [MD], −0.04 logarithm of the minimum angle of resolution [logMAR]; 95% confidence interval [CI], −0.07, −0.01; P = 0.006 and MD, −0.07 logMAR; 95% CI, −0.13, −0.01; P = 0.03, respectively). Postoperative refraction, glare, CS, and HOAs were not significantly different from each other. Conclusion The overall findings indicate that trifocal diffractive IOL implantation is better than the bifocal diffractive IOL in intermediate VA, and provides similar or better in distance and near VAs without any major deterioration in the visual quality.

[1]  J. Higgins,et al.  Cochrane Handbook for Systematic Reviews of Interventions , 2010, International Coaching Psychology Review.

[2]  B. Cochener,et al.  Quality of life related variables measured for three multifocal diffractive intraocular lenses: a prospective randomised clinical trial , 2018, Clinical & experimental ophthalmology.

[3]  S. Marcos,et al.  In Vivo Measurement of Longitudinal Chromatic Aberration in Patients Implanted With Trifocal Diffractive Intraocular Lenses. , 2017, Journal of refractive surgery.

[4]  Qiang Wu,et al.  Comparison of clinical performance between trifocal and bifocal intraocular lenses: A meta-analysis , 2017, PloS one.

[5]  D. Piñero,et al.  Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up. , 2017, International journal of ophthalmology.

[6]  B. Cochener,et al.  Visual Performance With Bifocal and Trifocal Diffractive Intraocular Lenses: A Prospective Three-Armed Randomized Multicenter Clinical Trial. , 2017, Journal of refractive surgery.

[7]  Maria S Millán,et al.  Extended depth of focus intraocular lens: Chromatic performance. , 2017, Biomedical optics express.

[8]  M. Alves,et al.  Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses , 2017, Clinical ophthalmology.

[9]  Zeren Shen,et al.  Clinical comparison of patient outcomes following implantation of trifocal or bifocal intraocular lenses: a systematic review and meta-analysis , 2017, Scientific Reports.

[10]  M. Leyland,et al.  Multifocal versus monofocal intraocular lenses after cataract extraction. , 2016, The Cochrane database of systematic reviews.

[11]  Sunni R. Patel,et al.  Comparison Between Mix-and-Match Implantation of Bifocal Intraocular Lenses and Bilateral Implantation of Trifocal Intraocular Lenses. , 2016, Journal of refractive surgery.

[12]  R. Potvin,et al.  Comparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses , 2016, Clinical ophthalmology.

[13]  Robert Montés-Micó,et al.  Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function , 2016, Journal of cataract and refractive surgery.

[14]  J. Alió,et al.  Impact of Low Mesopic Contrast Sensitivity Outcomes in Different Types of Modern Multifocal Intraocular Lenses , 2016, European journal of ophthalmology.

[15]  J. Alió,et al.  Analysis of Defocus Curves of Different Modern Multifocal Intraocular Lenses , 2016, European journal of ophthalmology.

[16]  M. S. Millán,et al.  Polychromatic Image Performance of Diffractive Bifocal Intraocular Lenses: Longitudinal Chromatic Aberration and Energy Efficiency. , 2016, Investigative ophthalmology & visual science.

[17]  R. Potvin,et al.  Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens , 2016, Clinical Ophthalmology (Auckland, N.Z.).

[18]  B. Cochener Prospective Clinical Comparison of Patient Outcomes Following Implantation of Trifocal or Bifocal Intraocular Lenses. , 2016, Journal of refractive surgery.

[19]  H. Yener,et al.  Visual outcomes of multifocal intraocular lens implantation in patients with cataract and high hyperopia and patient selection. , 2015, International journal of ophthalmology.

[20]  P. Vinciguerra,et al.  Visual Outcomes After Cataract Surgery: Multifocal Versus Monofocal Intraocular Lenses. , 2015, Journal of refractive surgery.

[21]  T. Berendschot,et al.  Comparison of a trifocal intraocular lens with a +3.0 D bifocal IOL: Results of a prospective randomized clinical trial , 2015, Journal of cataract and refractive surgery.

[22]  Oana Postolache,et al.  COMPARATION OF REFRACTIVE RESULTS WITH BIFOCAL IMPLANTS AT LISA 809 AND TRIFOCAL AT LISA TRI839. , 2015, Romanian journal of ophthalmology.

[23]  J. González-Méijome,et al.  Light‐distortion analysis as a possible indicator of visual quality after refractive lens exchange with diffractive multifocal intraocular lenses , 2015, Journal of cataract and refractive surgery.

[24]  E. Marques,et al.  Comparison of visual outcomes of 2 diffractive trifocal intraocular lenses , 2015, Journal of cataract and refractive surgery.

[25]  D. Piñero,et al.  Comparative analysis of the visual performance after cataract surgery with implantation of a bifocal or trifocal diffractive IOL. , 2014, Journal of refractive surgery.

[26]  Jiming Liu,et al.  Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range , 2014, BMC Medical Research Methodology.

[27]  W. Haw,et al.  Optimizing outcomes of multifocal intraocular lenses , 2014, Current opinion in ophthalmology.

[28]  Robert Montés-Micó,et al.  Optical quality differences between three multifocal intraocular lenses: bifocal low add, bifocal moderate add, and trifocal. , 2013, Journal of refractive surgery.

[29]  R. Montés-Micó,et al.  In vitro optical quality differences between multifocal apodized diffractive intraocular lenses , 2013, Journal of cataract and refractive surgery.

[30]  B. Cochener,et al.  Visual and refractive outcomes after implantation of a fully diffractive trifocal lens , 2012, Clinical ophthalmology.

[31]  Damien Gatinel,et al.  Design and qualification of a diffractive trifocal optical profile for intraocular lenses , 2011, Journal of cataract and refractive surgery.

[32]  T. Berendschot,et al.  Dissatisfaction after implantation of multifocal intraocular lenses , 2011, Journal of cataract and refractive surgery.

[33]  R. Montés-Micó,et al.  Visual outcomes after cataract surgery with implantation of a +3.00 D or +4.00 D aspheric diffractive multifocal intraocular lens: Comparative study , 2010, Journal of cataract and refractive surgery.

[34]  Anna Voskresenskaya,et al.  Initial results of trifocal diffractive IOL implantation , 2010, Graefe's Archive for Clinical and Experimental Ophthalmology.

[35]  P. Chiam,et al.  ReSTOR intraocular lens implantation in cataract surgery: Quality of vision , 2006, Journal of cataract and refractive surgery.

[36]  S. Chinn A simple method for converting an odds ratio to effect size for use in meta-analysis. , 2000, Statistics in medicine.

[37]  P. Mergo,et al.  A simple method for obtaining original data from published graphs and plots. , 2000, AJR. American journal of roentgenology.

[38]  R. Lindstrom,et al.  Multifocal intraocular lenses , 1990, Journal of cataract and refractive surgery.

[39]  Richard H. Keates,et al.  Clinical results of the multifocal lens , 1987, Journal of cataract and refractive surgery.

[40]  M. Leyland,et al.  Multifocal versus monofocal intraocular lenses after cataract extraction. , 2003, The Cochrane database of systematic reviews.

[41]  M. Leyland,et al.  Multifocal versus monofocal intraocular lenses after cataract extraction. , 2001, The Cochrane database of systematic reviews.