Do you hear the noise? The German matrix sentence test with a fixed noise level in subjects with normal hearing and hearing impairment

Objective: The aim of this study was to determine the relationship between hearing loss and speech reception threshold (SRT) in a fixed noise condition using the German Oldenburg sentence test (OLSA). Design: After training with two easily-audible lists of the OLSA, SRTs were determined monaurally with headphones at a fixed noise level of 65 dB SPL using a standard adaptive procedure, converging to 50% speech intelligibility. Study sample: Data was obtained from 315 ears of 177 subjects with hearing losses ranging from − 5 to 90 dB HL pure-tone average (PTA, 0.5, 1, 2, 3 kHz). Results: Two domains were identified with a linear dependence of SRT on PTA. The SRT increased with a slope of 0.094 ± 0.006 dB SNR/dB HL (standard deviation (SD) of residuals = 1.17 dB) for PTAs < 47 dB HL and with a slope of 0.811 ± 0.049 dB SNR/dB HL (SD of residuals = 5.54 dB) for higher PTAs. Conclusion: The OLSA can be applied to subjects with a wide range of hearing losses. With 65 dB SPL fixed noise presentation level the SRT is determined by listening in noise for PTAs < ∼47 dB HL, and above it is determined by listening in quiet.

[1]  H. Fletcher,et al.  The Perception of Speech and Its Relation to Telephony , 1950 .

[2]  R. Dobie,et al.  Letter to the Editor Response—Entong Wang , 2013, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[3]  H. Dillon,et al.  The Effects of Hearing Impairment and Aging on Spatial Processing , 2013, Ear and hearing.

[4]  K H HAHLBROCK,et al.  [Speech audiometry and new word-tests]. , 1953, Archiv fur Ohren-, Nasen- und Kehlkopfheilkunde.

[5]  T. Lenarz,et al.  [Göttingen sentence in noise for different audiogram classes]. , 2012, Laryngo- rhino- otologie.

[6]  J. P. Egan Articulation testing methods , 1948, The Laryngoscope.

[7]  Kirsten Carola Wagener,et al.  Factors influencing sentence intelligibility in noise , 2004 .

[8]  A. Winkler,et al.  Hörgeräteindikation und -überprüfung nach modernen Verfahren der Sprachaudiometrie im Deutschen , 2011, HNO.

[9]  Hari M. Bharadwaj,et al.  Cochlear neuropathy and the coding of supra-threshold sound , 2014, Front. Syst. Neurosci..

[10]  J. C. Steinberg,et al.  Factors Governing the Intelligibility of Speech Sounds , 1945 .

[11]  Anna Warzybok,et al.  The multilingual matrix test: Principles, applications, and comparison across languages: A review , 2015, International journal of audiology.

[12]  Karl-Heinz Hahlbrock,et al.  Über Sprachaudiometrie und neue Wörterteste , 2005, Archiv für Ohren-, Nasen- und Kehlkopfheilkunde.

[13]  P Van de Heyning,et al.  Quality standards for minimal outcome measurements in adults and children , 2013, Cochlear implants international.

[14]  Jochen Triesch,et al.  Spike avalanches in vivo suggest a driven, slightly subcritical brain state , 2014, Front. Syst. Neurosci..

[15]  B. Kollmeier,et al.  International Collegium of Rehabilitative Audiology (ICRA) recommendations for the construction of multilingual speech tests , 2015, International journal of audiology.

[16]  P. Van cauwenberge,et al.  Sensitivity of transient evoked and distortion product otoacoustic emissions to the direct effects of noise on the human cochlea. , 1999, Audiology : official organ of the International Society of Audiology.

[17]  B Hagerman,et al.  Sentences for testing speech intelligibility in noise. , 1982, Scandinavian audiology.

[18]  Birger Kollmeier,et al.  The role of silent intervals for sentence intelligibility in fluctuating noise in hearing-impaired listeners , 2006, International journal of audiology.

[19]  I. Hochmair-Desoyer,et al.  The HSM sentence test as a tool for evaluating the speech understanding in noise of cochlear implant users. , 1997, The American journal of otology.

[20]  Joachim Müller-Deile,et al.  Investigation of a matrix sentence test in noise: Reproducibility and discrimination function in cochlear implant patients , 2014, International journal of audiology.

[21]  J. Müller-Deile Sprachverständlichkeitsuntersuchungen bei Kochleaimplantatpatienten , 2009, HNO.

[22]  B Kollmeier,et al.  Development and evaluation of a German sentence test for objective and subjective speech intelligibility assessment. , 1997, The Journal of the Acoustical Society of America.

[23]  H. Dillon,et al.  Development of the North American Listening in Spatialized Noise-Sentences test (NA LiSN-S): sentence equivalence, normative data, and test-retest reliability studies. , 2009, Journal of the American Academy of Audiology.

[24]  Anna Warzybok,et al.  Speech-in-noise tests for multilingual hearing screening and diagnostics1. , 2013, American journal of audiology.

[25]  Birger Kollmeier,et al.  Efficient adaptive procedures for threshold and concurrent slope estimates for psychophysics and speech intelligibility tests. , 2002, The Journal of the Acoustical Society of America.