Monitoring cardiac output and left atrial pressure by analysis of the right ventricular pressure waveform based on missing output identification

A proven implantable device is now available for long-term ambulatory monitoring of the right ventricular pressure (RVP) waveform of congestive heart failure patients. However, cardiac output (CO) and left atrial pressure (LAP) are far more useful for assessing cardiac function and managing volume status. We developed a new technique to monitor both CO and LAP by analysis of the RVP waveform based on missing output identification. We initially evaluated the technique against gold standard reference CO and LAP measurements from two dogs during common hemodynamic interventions. We report overall CO and LAP errors of 13.3% and 1.9 mmHg, respectively. With further successful testing, the technique may potentially be employed with an established implantable device for chronic monitoring of vital hemodynamic variables.

[1]  Roger G. Mark,et al.  Continuous cardiac output monitoring by peripheral blood pressure waveform analysis , 2006, IEEE Transactions on Biomedical Engineering.

[2]  A. Noordergraaf Circulatory System Dynamics , 1978 .

[3]  R. Wilson,et al.  Measurement of pulmonary artery diastolic pressure from a right ventricular pressure transducer in patients with heart failure. , 1996, Journal of cardiac failure.

[4]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[5]  S Adler,et al.  Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: results of a 1 year multicentre feasibility study. , 2001, European heart journal.

[6]  D. Reynolds,et al.  Measurement of pulmonary artery diastolic pressure from the right ventricle. , 1995, Journal of the American College of Cardiology.

[7]  L. Rydén,et al.  Monitoring of pulmonary arterial diastolic pressure through a right ventricular pressure transducer. , 1995, Journal of cardiac failure.

[8]  Ramakrishna Mukkamala,et al.  Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs. , 2009, Journal of applied physiology.

[9]  R. Mukkamala,et al.  Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis. , 2006, Journal of applied physiology.

[10]  L. Rydén,et al.  Continuous ambulatory haemodynamic monitoring with an implantable system. The feasibility of a new technique. , 1998, European heart journal.

[11]  Philip Adamson,et al.  Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: a multicenter, 12-month follow-up study of patients with chronic heart failure. , 2002, Journal of cardiac failure.