High-resolution wide-angle X-ray scattering of protein solutions: effect of beam dose on protein integrity.

Wide-angle X-ray scattering patterns from proteins in solution contain information relevant to the determination of protein fold. At relevant scattering angles, however, these data are weak, and the degree to which they might be used to categorize the fold of a protein is unknown. Preliminary work has been performed at the BioCAT insertion-device beamline at the Advanced Photon Source which demonstrates that one can collect X-ray scattering data from proteins in solution to spacings of at least 2.2 A (q = 2.8 A(-1)). These data are sensitive to protein conformational states, and are in good agreement with the scattering predicted by the program CRYSOL using the known three-dimensional atomic coordinates of the protein. An important issue in the exploitation of this technique as a tool for structural genomics is the extent to which the high intensity of X-rays available at third-generation synchrotron sources chemically or structurally damage proteins. Various data-collection protocols have been investigated demonstrating conditions under which structural degradation of even sensitive proteins can be minimized, making this technique a viable tool for protein fold categorization, the study of protein folding, unfolding, protein-ligand interactions and domain movement.

[1]  D I Svergun,et al.  Determination of domain structure of proteins from X-ray solution scattering. , 2001, Biophysical journal.

[2]  B. Melnik,et al.  GroES co‐chaperonin small‐angle X‐ray scattering study shows ring orifice increase in solution , 2000, FEBS letters.

[3]  D. Svergun,et al.  CRYSOL : a program to evaluate X-ray solution scattering of biological macromolecules from atomic coordinates , 1995 .

[4]  J. Olson,et al.  The stability of holomyoglobin is determined by heme affinity. , 1996, Biochemistry.

[5]  K. Davies Protein damage and degradation by oxygen radicals. I. general aspects. , 1987, The Journal of biological chemistry.

[6]  J. Trewhella,et al.  Comparison of the crystal and solution structures of calmodulin and troponin C. , 1988, Biochemistry.

[7]  J. Olson,et al.  Quaternary Structure Regulates Hemin Dissociation from Human Hemoglobin* , 1997, The Journal of Biological Chemistry.

[8]  Robert F. Fischetti,et al.  Fiber diffraction using the BioCAT undulator beamline at the Advanced Photon Source , 2000 .

[9]  J. Helliwell Protein crystal perfection and the nature of radiation damage , 1988 .

[10]  K. Hodgson,et al.  Small-angle x-ray scattering investigation of the solution structure of troponin C. , 1988, The Journal of biological chemistry.

[11]  A. P. Hammersley,et al.  Two-dimensional detector software: From real detector to idealised image or two-theta scan , 1996 .

[12]  U. K. Laemmli,et al.  Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4 , 1970, Nature.