A respiratory-gated treatment system for proton therapy.

Proton therapy offers the potential for excellent dose conformity and reduction in integral dose. The superior dose distribution is, however, much more sensitive to changes in radiological depths along the beam path than for photon fields. Respiratory motion can cause such changes for treatments sites like lung, liver, and mediastinum and thus affect the proton dose distribution significantly. We have implemented and commissioned a respiratory-gated system for range-modulated treatment fields. The gating system was designed to ensure that each gate always contains complete modulation cycles so that for any beam segment the delivered dose has the planned depth-dose distribution. Measurements have been made to estimate the time delays for the various components of the system. The total delay between the actual motion and the beam on/off control is in the range of 65-195 ms. Time-resolved dose measurements and film tests were also conducted to examine the overall gating effect.

[1]  Hanne M Kooy,et al.  Target volume dose considerations in proton beam treatment planning for lung tumors. , 2005, Medical physics.

[2]  Steve B. Jiang,et al.  Technical aspects of image-guided respiration-gated radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[3]  Shinichi Minohara,et al.  Estimating uncertainties of the geometrical range of particle radiotherapy during respiration. , 2003, International journal of radiation oncology, biology, physics.

[4]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[5]  Eike Rietzel,et al.  Four-dimensional proton treatment planning for lung tumors. , 2006, International journal of radiation oncology, biology, physics.

[6]  S Minohara,et al.  Respiratory gated irradiation system for heavy-ion radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[7]  Robert J. Schneider,et al.  Range modulators for protons and heavy ions , 1975 .

[8]  Fang-Fang Yin,et al.  Time delay measurement for linac based treatment delivery in synchronized respiratory gating radiotherapy. , 2005, Medical physics.

[9]  Hsiao-Ming Lu,et al.  Optimization of current modulation function for proton spread-out Bragg peak fields. , 2006, Medical physics.

[10]  H Paganetti,et al.  Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility. , 2004, Medical physics.

[11]  Tinsu Pan,et al.  Four-dimensional computed tomography: image formation and clinical protocol. , 2005, Medical physics.