Differences in restenosis rate with different drug-eluting stents in patients with and without diabetes mellitus: a report from the SCAAR (Swedish Angiography and Angioplasty Registry).

OBJECTIVES Our aim was to evaluate restenosis rate of drug-eluting stents (DES) in patients with and without diabetes mellitus (DM) in a real-world setting. BACKGROUND DES seem less effective in patients with DM. METHODS The SCAAR (Swedish Coronary Angiography and Angioplasty Registry) includes all patients undergoing percutaneous coronary intervention in Sweden. From April 1, 2004, to April 20, 2008, all restenoses detected at a subsequent angiography and all DES types implanted at more than 500 occasions were assessed using Cox regression. RESULTS Four DES types qualified for inclusion. In total, 35,478 DES were implanted at 22,962 procedures in 19,004 patients and 1,807 restenoses were reported over a mean 29 months follow-up. In the entire population, the restenosis rate per stent was 3.5% after 1 year and 4.9% after 2 years. The adjusted risk of restenosis was higher in patients with DM compared with that in patients without DM (relative risk [RR]: 1.23, 95% confidence interval [CI]: 1.10 to 1.37). In patients with DM, restenosis was twice as frequent with the zotarolimus-eluting Endeavor stent (Medtronic, Minneapolis, Minnesota) compared with that in the other DES types. The Endeavor stent and the sirolimus-eluting Cypher stent (Cordis, Johnson & Johnson, Miami, Florida) had higher restenosis rates in patients with DM compared with those in patients without DM (RR: 1.77, 95% CI: 1.29 to 2.43 and RR: 1.25, 95% CI: 1.04 to 1.51). Restenosis rate with the paclitaxel-eluting Taxus Express and Liberté (Boston Scientific, Natick, Massachusetts) stents was unrelated to DM. Mortality did not differ between different DES. CONCLUSIONS Restenosis rate with DES was higher in patients with DM compared with that in patients without DM. There seem to be important differences between different brands of DES.

[1]  H. Drexler,et al.  One-year results of the SCORPIUS study: a German multicenter investigation on the effectiveness of sirolimus-eluting stents in diabetic patients. , 2007, Journal of the American College of Cardiology.

[2]  K. Kent,et al.  Sirolimus-eluting stents versus Paclitaxel-eluting stents in the treatment of coronary artery disease in patients with diabetes mellitus. , 2006, The American journal of cardiology.

[3]  F. Fernández‐Avilés,et al.  Randomized Comparison of Sirolimus-Eluting Stent Versus Standard Stent for Percutaneous Coronary Revascularization in Diabetic Patients: The Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial , 2005, Circulation.

[4]  P. Fitzgerald,et al.  Randomized, Double-Blind, Multicenter Study of the Endeavor Zotarolimus-Eluting Phosphorylcholine-Encapsulated Stent for Treatment of Native Coronary Artery Lesions: Clinical and Angiographic Results of the ENDEAVOR II Trial , 2006, Circulation.

[5]  P. Serruys,et al.  Comparison of short- (one month) and long- (twelve months) term outcomes of sirolimus- versus paclitaxel-eluting stents in 293 consecutive patients with diabetes mellitus (from the RESEARCH and T-SEARCH registries). , 2005, American Journal of Cardiology.

[6]  F. Prati,et al.  Head-to-Head Comparison of Sirolimus- and Paclitaxel-Eluting Stent in the Same Diabetic Patient With Multiple Coronary Artery Lesions , 2008, Diabetes Care.

[7]  R. M. Cooke,et al.  Two-Year Clinical Outcomes With Drug-Eluting Stents for Diabetic Patients With De Novo Coronary Lesions: Results From a Real-World Multicenter Registry , 2008, Circulation.

[8]  I. Iakovou,et al.  Impact of sirolimus-eluting and Paclitaxel-eluting stents on outcome in patients with diabetes mellitus and stenting in more than one coronary artery. , 2006, The American journal of cardiology.

[9]  G. Stone,et al.  Paclitaxel-eluting coronary stents in patients with diabetes mellitus: pooled analysis from 5 randomized trials. , 2008, Journal of the American College of Cardiology.

[10]  M. Hadamitzky,et al.  Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement. , 1998, Journal of the American College of Cardiology.

[11]  P. Serruys,et al.  Predictors of clinical outcome following NIR stent implantation for coronary artery disease: analysis of the results of the First International New Intravascular Rigid-Flex Endovascular Stent Study (FINESS trial). , 2002, Journal of interventional cardiology.

[12]  F. Eberli,et al.  Two-year clinical outcome after implantation of sirolimus-eluting and paclitaxel-eluting stents in diabetic patients. , 2008, European heart journal.

[13]  A. Kastrati,et al.  Paclitaxel-eluting or sirolimus-eluting stents to prevent restenosis in diabetic patients. , 2005, The New England journal of medicine.

[14]  R. Whitbourn,et al.  Four-year clinical follow-up after implantation of the endeavor zotarolimus-eluting stent: ENDEAVOR I, the first-in-human study. , 2007, The American journal of cardiology.

[15]  E. Mahmud,et al.  Clinical efficacy of drug-eluting stents in diabetic patients: a meta-analysis. , 2008, Journal of the American College of Cardiology.