The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels
暂无分享,去创建一个
C De Wagter | C. De Wagter | Y. D. Deene | Y. De Deene | K. Vergote | Y De Deene | K Vergote | C Claeys | C. Claeys | C. Wagter
[1] C Baldock,et al. Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters. , 2002, Physics in medicine and biology.
[2] J C Gore,et al. Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter. , 1997, Physics in medicine and biology.
[3] C. De Wagter,et al. On the relation between the spatial dose integrity and the temporal instability of polymer gel dosimeters. , 2004, Physics in medicine and biology.
[4] C. De Wagter,et al. On the accuracy of monomer/polymer gel dosimetry in the proximity of a high-dose-rate 192Ir source. , 2001, Physics in medicine and biology.
[5] T. Holmes,et al. Acceptance testing computerized radiation therapy treatment planning systems: direct utilization of CT scan data. , 1985, Medical physics.
[6] C. Baldock,et al. The relationship between radiation-induced chemical processes and transverse relaxation times in polymer gel dosimeters. , 2001, Physics in medicine and biology.
[7] T Kron,et al. Investigation of the tissue equivalence of gels used for NMR dosimetry. , 1993, Physics in medicine and biology.
[8] E. McCullough,et al. Photon attenuation in computed tomography. , 1975, Medical physics.
[9] P Keall,et al. A theoretical study of the radiological properties and water equivalence of Fricke and polymer gels used for radiation dosimetry. , 1999, Australasian physical & engineering sciences in medicine.
[10] C. De Wagter,et al. Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[11] J. Gore,et al. Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. , 2001, Physics in medicine and biology.
[12] E Pantelis,et al. Polymer gel water equivalence and relative energy response with emphasis on low photon energy dosimetry in brachytherapy. , 2004, Physics in medicine and biology.
[13] C De Wagter,et al. An investigation of the chemical stability of a monomer/polymer gel dosimeter. , 2000, Physics in medicine and biology.
[14] J C Gore,et al. Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter , 1994, Physics in medicine and biology.
[15] C. D. Wagter,et al. Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: III. Effects of temperature drift during scanning. , 2001 .
[16] C Baldock,et al. A basic study of some normoxic polymer gel dosimeters. , 2002, Physics in medicine and biology.
[17] Temperature increases associated with polymerization of irradiated PAG dosimeters. , 2002, Physics in medicine and biology.
[18] C Duzenli,et al. Effects of crosslinker fraction in polymer gel dosimeters using FT Raman spectroscopy. , 2001, Physics in medicine and biology.
[19] P. Dvorák,et al. Energy and dose rate dependence of BANG-2 polymer-gel dosimeter. , 2001, Medical physics.
[20] B M Rao,et al. Interaction of low-energy photons with biological materials and the effective atomic number. , 1985, Medical physics.
[21] M. Mather,et al. Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters. , 2002, Physics in medicine and biology.
[22] J. Vymazal,et al. Temperature dependence of polymer-gel dosimeter nuclear magnetic resonance response. , 2001, Medical physics.