The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels

Polymer gel dosimeters offer a wide range of applications in the three-dimensional verification of complex dose distributions such as in intensity-modulated radiotherapy. One of the major difficulties with polymer gel dosimeters is their sensitivity to oxygen, as oxygen inhibits the radiation-induced polymerization reaction. For several years, oxygen was removed from the gels by bubbling the sol with inert gases for several hours during the gel fabrication. Also, the gel had to be poured in containers with low oxygen permeability and solubility. Recently, it was found that these technical difficulties can easily be solved by adding an antioxidant to the gel. These gels are called 'normoxic' gels as they can be produced under normal atmospheric conditions. In this study several properties of polymer gel dosimeters have been investigated: the dose sensitivity, the temporal and spatial stability of the gel, the sensitivity of the dose response to temperature during irradiation and during MR imaging, the energy dependence and the dose-rate dependence. This study reveals that the normoxic polymer gel dosimeter based on methacrylic acid (nMAG) studied in this work has inferior radiation properties as compared to the polyacrylamide gelatine (PAG) gel dosimeters. It is shown that from the three different gel dosimeters investigated in this study, the nPAG gel dosimeter results in a less sensitive gel dosimeter but with superior radiation properties as compared to the nMAG gel dosimeter. The importance of investigating relevant radiation properties of gel dosimeters apart from the radiation sensitivity-prior to their use for dosimetric validation experiments-is illustrated and emphasized throughout this study. Other combinations of monomer and gelling agent may result in more reliable normoxic polymer gel dosimeters.

[1]  C Baldock,et al.  Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters. , 2002, Physics in medicine and biology.

[2]  J C Gore,et al.  Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter. , 1997, Physics in medicine and biology.

[3]  C. De Wagter,et al.  On the relation between the spatial dose integrity and the temporal instability of polymer gel dosimeters. , 2004, Physics in medicine and biology.

[4]  C. De Wagter,et al.  On the accuracy of monomer/polymer gel dosimetry in the proximity of a high-dose-rate 192Ir source. , 2001, Physics in medicine and biology.

[5]  T. Holmes,et al.  Acceptance testing computerized radiation therapy treatment planning systems: direct utilization of CT scan data. , 1985, Medical physics.

[6]  C. Baldock,et al.  The relationship between radiation-induced chemical processes and transverse relaxation times in polymer gel dosimeters. , 2001, Physics in medicine and biology.

[7]  T Kron,et al.  Investigation of the tissue equivalence of gels used for NMR dosimetry. , 1993, Physics in medicine and biology.

[8]  E. McCullough,et al.  Photon attenuation in computed tomography. , 1975, Medical physics.

[9]  P Keall,et al.  A theoretical study of the radiological properties and water equivalence of Fricke and polymer gels used for radiation dosimetry. , 1999, Australasian physical & engineering sciences in medicine.

[10]  C. De Wagter,et al.  Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  J. Gore,et al.  Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. , 2001, Physics in medicine and biology.

[12]  E Pantelis,et al.  Polymer gel water equivalence and relative energy response with emphasis on low photon energy dosimetry in brachytherapy. , 2004, Physics in medicine and biology.

[13]  C De Wagter,et al.  An investigation of the chemical stability of a monomer/polymer gel dosimeter. , 2000, Physics in medicine and biology.

[14]  J C Gore,et al.  Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter , 1994, Physics in medicine and biology.

[15]  C. D. Wagter,et al.  Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: III. Effects of temperature drift during scanning. , 2001 .

[16]  C Baldock,et al.  A basic study of some normoxic polymer gel dosimeters. , 2002, Physics in medicine and biology.

[17]  Temperature increases associated with polymerization of irradiated PAG dosimeters. , 2002, Physics in medicine and biology.

[18]  C Duzenli,et al.  Effects of crosslinker fraction in polymer gel dosimeters using FT Raman spectroscopy. , 2001, Physics in medicine and biology.

[19]  P. Dvorák,et al.  Energy and dose rate dependence of BANG-2 polymer-gel dosimeter. , 2001, Medical physics.

[20]  B M Rao,et al.  Interaction of low-energy photons with biological materials and the effective atomic number. , 1985, Medical physics.

[21]  M. Mather,et al.  Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters , 2002, Physics in medicine and biology.

[22]  J. Vymazal,et al.  Temperature dependence of polymer-gel dosimeter nuclear magnetic resonance response. , 2001, Medical physics.