The cardiovascular response to an acute 1800-μT, 60-Hz magnetic field exposure in humans

PurposePreviously published literature has suggested an effect of extremely low-frequency (ELF) magnetic fields (MF) on human heart rate (HR) and heart rate variability (HRV). The combined response of the microcirculation and macrocirculation to ELF MF exposure has not previously been studied in humans. This study investigated the effects of 1-h exposure to an 1800-μT, 60-Hz MF on human microcirculation (represented in this study as skin blood perfusion), HR, low-frequency HRV, and high-frequency HRV.MethodsFifty-eight volunteers were recruited to partake in a double-blinded, counterbalanced study consisting of two testing sessions (real and sham) administered on separate days. Each session included four consecutive blocks of measurements, separated by 15-min rest periods, allowing measurement of cumulative and residual MF effects. Within subjects, ANOVA were conducted on each of the measured parameters.ResultsA decrease of skin blood perfusion and HR, and an increase of HRV were observed over blocks (p < 0.05). No session by block interactions were found for any of the cardiovascular parameters which would have suggested a MF effect (p > 0.05). A session by block interaction (p < 0.001) and a MF order effect (sham or real exposure first, p < 0.05) were observed for skin surface temperature.ConclusionsThe MF used in this experiment did not affect cardiovascular parameters. Although an alternative explanation for why skin surface temperatures decreased in the sham and not in the real exposure condition is presented, the possibility of a MF effect cannot be excluded.

[1]  G. Schmid-Schönbein,et al.  Biomechanics of microcirculatory blood perfusion. , 1999, Annual review of biomedical engineering.

[2]  G. Kenny,et al.  15 degrees head-down tilt attenuates the postexercise reduction in cutaneous vascular conductance and sweating and decreases esophageal temperature recovery time. , 2006, Journal of applied physiology.

[3]  M. Repacholi,et al.  Interaction of static and extremely low frequency electric and magnetic fields with living systems: health effects and research needs. , 1999, Bioelectromagnetics.

[4]  Heikki Rusko,et al.  Time-frequency analysis of heart rate variability during immediate recovery from low and high intensity exercise , 2007, European Journal of Applied Physiology.

[5]  H. Gutzeit,et al.  Weak electromagnetic fields (50 Hz) elicit a stress response in human cells. , 2004, Environmental research.

[6]  Effects of 50 Hz magnetic field exposure on human heart rate variability with passive tilting. , 2006, Physiological measurement.

[7]  Lynn Keenliside,et al.  Resting EEG effects during exposure to a pulsed ELF magnetic field , 2005, Bioelectromagnetics.

[8]  G. Breithardt,et al.  Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. , 1996 .

[9]  John M. Johnson,et al.  3: Exercise and the Cutaneous Circulation , 1992 .

[10]  H D Cohen,et al.  Dose response study of human exposure to 60 Hz electric and magnetic fields. , 1994, Bioelectromagnetics.

[11]  H D Cohen,et al.  A replication study of human exposure to 60-Hz fields: effects on neurobehavioral measures. , 1992, Bioelectromagnetics.

[12]  H. Wollersheim,et al.  Reproducibility of skin microcirculatory measurements in humans, with special emphasis on capillaroscopy , 2001, Vascular medicine.

[13]  O P Gandhi,et al.  Comparison of cardiac-induced endogenous fields and power frequency induced exogenous fields in an anatomical model of the human body. , 1998, Physics in medicine and biology.

[14]  C. Graham,et al.  Brain frequency magnetic fields alter cardiac autonomic control mechanisms , 2000, Clinical Neurophysiology.

[15]  A. Tonevitsky,et al.  Modulation of cardiac rhythm in the humans exposed to extremely weak alternating magnetic fields , 2008 .

[16]  Jeffrey R Stout,et al.  Acute Effects of a Thermogenic Nutritional Supplement on Energy Expenditure and Cardiovascular Function at Rest, During Low-Intensity Exercise, and Recovery from Exercise , 2009, Journal of strength and conditioning research.

[17]  L. Luecken,et al.  Measuring Task-related Changes in Heart Rate Variability , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  H Kingma,et al.  Thresholds for perception of direction of linear acceleration as a possible evaluation of the otolith function , 2005, BMC ear, nose, and throat disorders.

[19]  Luca Bonfiglio,et al.  Effects of 50Hz electromagnetic fields on electroencephalographic alpha activity, dental pain threshold and cardiovascular parameters in humans , 2005, Neuroscience Letters.

[20]  A. Sastre,et al.  Magnetic field exposure and cardiovascular disease mortality among electric utility workers. , 1999, American journal of epidemiology.

[21]  Mircea Miclea,et al.  Reduced heart rate variability and vagal tone in anxiety: Trait versus state, and the effects of autogenic training , 2009, Autonomic Neuroscience.

[22]  Marek Zmyślony,et al.  Neurovegetative disturbances in workers exposed to 50 Hz electromagnetic fields. , 2006, International journal of occupational medicine and environmental health.

[23]  G. Kenny,et al.  Disturbance of thermal homeostasis during post-exercise hyperthermia , 2004, European Journal of Applied Physiology and Occupational Physiology.

[24]  C. Ohkubo,et al.  Anti‐pressor effects of whole body exposure to static magnetic field on pharmacologically induced hypertension in conscious rabbits , 2003, Bioelectromagnetics.

[25]  J. Partanen,et al.  Influence of 50-Hz electric and magnetic fields on human blood pressure , 1996, Radiation and environmental biophysics.

[26]  Per Gustavsson,et al.  Occupational exposure to extremely low frequency magnetic fields and mortality from cardiovascular disease. , 2003, American journal of epidemiology.

[27]  W. L. Kenney,et al.  Control of skin blood flow during exercise. , 1992, Medicine and science in sports and exercise.

[28]  W S Gunn,et al.  Exercise testing in the evaluation of human responses to powerline frequency fields. , 1988, Aviation, space, and environmental medicine.

[29]  D. Levy,et al.  Impact of reduced heart rate variability on risk for cardiac events. The Framingham Heart Study. , 1996, Circulation.

[30]  A. Sastre,et al.  CANDIDATE SITES OF ACTION FOR MICRODOSIMETRY ASSOCIATED WITH EXPOSURE TO EXTREMELY-LOW-FREQUENCY MAGNETIC FIELDS, ELECTRIC FIELDS AND CONTACT CURRENTS , 2002, Health physics.

[31]  L Korpinen,et al.  Influence of 50 Hz electric and magnetic fields on the human heart. , 1993, Bioelectromagnetics.

[32]  M R Cook,et al.  Nocturnal exposure to intermittent 60 Hz magnetic fields alters human cardiac rhythm. , 1998, Bioelectromagnetics.

[33]  P. Dimbylow,et al.  Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body. , 1998, Physics in medicine and biology.

[34]  A. Pilla,et al.  Effects of permanent magnets on resting skin blood perfusion in healthy persons assessed by laser doppler flowmetry and imaging , 2001, Bioelectromagnetics.

[35]  S. Takahashi,et al.  Reliability of Fingertip Skin-surface Temperature and its Related Thermal Measures as Indices of Peripheral Perfusion in the Clinical Setting of the Operating Theatre , 2004, Anaesthesia and intensive care.

[36]  M. Crumpton The Bernal Lecture 2004 Are low-frequency electromagnetic fields a health hazard? , 2005, Philosophical Transactions of the Royal Society B: Biological Sciences.

[37]  Catrin Bauréus Koch,et al.  Interaction between weak low frequency magnetic fields and cell membranes , 2003, Bioelectromagnetics.

[38]  F. Prato,et al.  A literature review: the cardiovascular effects of exposure to extremely low frequency electromagnetic fields , 2009, International archives of occupational and environmental health.

[39]  J. Bonnell Effects of Electric Fields near Power-Transmission Plant , 1982, Journal of the Royal Society of Medicine.

[40]  D Kromhout,et al.  Heart rate variability from short electrocardiographic recordings predicts mortality from all causes in middle-aged and elderly men. The Zutphen Study. , 1997, American journal of epidemiology.

[41]  F. Prato,et al.  Extremely low frequency pulsed electromagnetic field designed for antinociception does not affect microvascular responsiveness to the vasodilator acetylcholine , 2009, Bioelectromagnetics.

[42]  Martin Blank,et al.  Regulating genes with electromagnetic response elements , 2001, Journal of cellular biochemistry.

[43]  Emilio Baldi,et al.  A pilot investigation of the effect of extremely low frequency pulsed electromagnetic fields on humans' heart rate variability , 2007, Bioelectromagnetics.

[44]  W. H. Bailey,et al.  Evaluation of biological effects, dosimetric models, and exposure assessment related to ELF electric- and magnetic-field guidelines. , 2001, Applied occupational and environmental hygiene.

[45]  B. Wallin,et al.  Sympathetic neural control of integrated cardiovascular function: Insights from measurement of human sympathetic nerve activity , 2007, Muscle & nerve.

[46]  C. Graham,et al.  Cardiac autonomic control mechanisms in power-frequency magnetic fields: a multistudy analysis. , 2000, Environmental health perspectives.

[47]  B. Saltin,et al.  Esophageal, rectal, and muscle temperature during exercise. , 1966, Journal of applied physiology.

[48]  H. Nitta,et al.  Can extremely low frequency alternating magnetic fields modulate heart rate or its variability in humans? , 2003, Autonomic Neuroscience.

[49]  P. Brambilla,et al.  Electrophysiological changes of cardiac function during antidepressant treatment , 2009, Therapeutic advances in cardiovascular disease.

[50]  F. Wenzel,et al.  Cutaneous Microcirculation is not altered by a Weak 50 Hz Magnetic Field / Die Mikrozirkulation der Haut in schwachen 50-Hz-Magnetfeldern , 2005, Biomedizinische Technik. Biomedical engineering.

[51]  R. Hesketh,et al.  Biological responses to electromagnetic fields 1 , 1998, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[52]  A. Malliani,et al.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use , 1996 .

[53]  C. Ohkubo,et al.  Acute effects of whole-body exposure to static magnetic fields and 50-Hz electromagnetic fields on muscle microcirculation in anesthetized mice. , 2001, Bioelectrochemistry.

[54]  L Korpinen,et al.  Influence of 50 Hz electric and magnetic fields on the pulse rate of human heart. , 1994, Bioelectromagnetics.

[55]  V. Fialka-Moser,et al.  The effects of low-dosed and high-dosed low-frequency electromagnetic fields on microcirculation and skin temperature in healthy subjects. , 2005, International journal of sports medicine.