PICEP: Pipe Crack Evaluation Program

We describe a computer program that calculates the crack-opening area, the critical (stable) crack length and the two-phase flow rate through cracks in ductile stainless steel pipes and steam generator tubes. The program is useful in performing leak-before-break calculations in order to demonstrate detectable leak rates prior to a through-wall flaw reaching critical size. Necessary input to the code includes a definition of material properties, loads, thermal-hydraulic conditions, pipe geometry, and crack orientation. User information is provided in the report.