Coaxial personalized ventilation system and window performance for human thermal comfort in asymmetrical environment

Abstract This paper assesses the energy performance and occupant comfort of a ceiling-mounted coaxial personalized ventilation (PV) system in presence of radiation asymmetry due to a large window for different glazing systems. Detailed 3-D computational fluid dynamics (CFD) simulations were performed to study the flow and thermal fields in the conditioned office space and evaluate longwave and diffuse shortwave radiation effect on the occupant seated directly below the PV nozzle. The CFD model was coupled to a bioheat model to predict the corresponding local and overall thermal comfort of human body parts subject to the asymmetrical environment. The CFD model is validated by conducting experiments in a climatic room equipped with the PV system and using a thermal manikin facing a hot surface. Predicted and measured values of segmental skin and air temperature at the vicinity of the thermal manikin are compared. Good agreement (less than 8% error) was found between the measured and predicted values. Extensive simulations were performed to evaluate the effect of different types of window glazing on the perceived thermal comfort under various PV operating parameters. For high performance window, the coaxial PV system achieved remarkable energy savings up to 36% when was compared to mixing ventilation (MV) system at the same level of thermal comfort and environmental outdoor conditions.

[1]  Tin-Tai Chow,et al.  Comparison of annual energy performances with different ventilation methods for cooling , 2011 .

[2]  Bin Yang,et al.  Performance Evaluation of Ceiling Mounted Personalized Ventilation System , 2009 .

[3]  Chandra Sekhar,et al.  Ceiling mounted personalized ventilation system in hot and humid climate—An energy analysis , 2010 .

[4]  K. F. Fong,et al.  Comparison of performances of displacement and mixing ventilations. Part II: indoor air quality , 2005 .

[5]  Hui Zhang,et al.  Comfort, perceived air quality, and work performance in a low-power task–ambient conditioning system , 2008 .

[6]  Bjarne W. Olesen,et al.  Introduction to thermal comfort standards and to the proposed new version of EN ISO 7730 , 2002 .

[7]  Ali Assi,et al.  Global and Diffuse Solar Radiation in the United Arab Emirates , 2013 .

[8]  Kamel Ghali,et al.  Chilled ceiling and displacement ventilation aided with personalized evaporative cooler , 2011 .

[9]  Qingyan Chen,et al.  A computational method for calculating heat transfer and airflow through a dual-airflow window , 2008 .

[10]  Arsen Krikor Melikov,et al.  Performance of “ductless” personalized ventilation in conjunction with displacement ventilation: Impact of intake height , 2010 .

[11]  Kostas Laskos,et al.  Assessing cooling energy performance of windows for office buildings in the Mediterranean zone , 2012 .

[12]  Alain Makhoul,et al.  Ceiling-Mounted Fresh Air Personalized Ventilator System for Occupant-Controlled Microenvironment , 2012 .

[13]  N. Ghaddar,et al.  A new transient bioheat model of the human body and its integration to clothing models , 2007 .

[14]  Alessandro Prada,et al.  Passive performance of glazed components in heating and cooling of an open-space office under controlled indoor thermal comfort , 2014 .

[15]  Kamel Ghali,et al.  Assessing thermal comfort of active people in transitional spaces in presence of air movement , 2011 .

[16]  Arsen Krikor Melikov,et al.  Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate , 2010 .

[17]  Hui Zhang,et al.  Thermal sensation and comfort models for non-uniform and transient environments: Part III: whole-body sensation and comfort , 2009 .

[18]  K. F. Fong,et al.  Comparison of performances of displacement and mixing ventilations. Part I: thermal comfort , 2005 .

[19]  Shafqat Hussain,et al.  Numerical investigations of buoyancy-driven natural ventilation in a simple three-storey atrium building and thermal comfort evaluation , 2013 .

[20]  Muhsin Kilic,et al.  Modelling airflow, heat transfer and moisture transport around a standing human body by computational fluid dynamics , 2008 .

[21]  Muhsin Kilic,et al.  Investigation of transient cooling of an automobile cabin with a virtual manikin under solar radiation , 2013 .

[22]  Shafqat Hussain,et al.  Numerical investigations of buoyancy-driven natural ventilation in a simple atrium building and its effect on the thermal comfort conditions , 2012 .

[23]  K. F. Fong,et al.  Comparison of annual energy performances with different ventilation methods for temperature and humi , 2011 .

[24]  J. Palyvos A survey of wind convection coefficient correlations for building envelope energy systems’ modeling , 2008 .

[25]  Sabine Hoffmann,et al.  Assessing thermal comfort near glass facades with new tools , 2012 .

[26]  Edward Arens,et al.  Thermal sensation and comfort models for non-uniform and transient environments: Part I: local sensation of individual body parts , 2009 .

[27]  Ruey Lung Hwang,et al.  Building envelope regulations on thermal comfort in glass facade buildings and energy-saving potenti , 2011 .

[28]  Baizhan Li,et al.  Physiological Expression of Human Thermal Comfort to Indoor Operative Temperature in the Non-HVAC Environment: , 2010 .

[29]  Hui Zhang,et al.  Window performance for human thermal comfort , 2006 .

[30]  Kamel Ghali,et al.  Steady Thermal Comfort by Radiant Heat Transfer: The Impact of the Heater Position , 2006 .

[31]  Alain Makhoul,et al.  Thermal comfort and energy performance of a low-mixing ceiling-mounted personalized ventilator system , 2013 .