A comparison of 2D and 3D digital image correlation for a membrane under inflation.
暂无分享,去创建一个
[1] Thomas Becker,et al. Error Estimations in Digital Image Correlation Technique , 2007 .
[2] Zhenxing Hu,et al. Fluorescent stereo microscopy for 3D surface profilometry and deformation mapping. , 2013, Optics express.
[3] Hung-Yi Lin,et al. Mechanical properties of polymer thin film measured by the bulge test , 2007 .
[4] E. Hæggström,et al. Mechanical assessment of suspended ALD thin films by bulge and shaft loading techniques , 2014 .
[5] Michael A. Sutton,et al. The effect of out-of-plane motion on 2D and 3D digital image correlation measurements , 2008 .
[6] H. Haddadi,et al. Use of rigid-body motion for the investigation and estimation of the measurement errors related to digital image correlation technique , 2008 .
[7] Cheng Guo,et al. Photogrammetry-based two-dimensional digital image correlation with nonperpendicular camera alignment , 2012 .
[8] Xi Chen,et al. The Mechanical Properties of Electroplated Cu Thin Films Measured by means of the Bulge Test Technique , 2001 .
[9] Katia Genovese,et al. Stereo-Digital Image Correlation (DIC) measurements with a single camera using a biprism , 2013 .
[10] Taylan Altan,et al. Evaluation of tube formability and material characteristics: hydraulic bulge testing of tubes , 2000 .
[11] Michael A. Sutton,et al. Advances in light microscope stereo vision , 2004 .
[12] C. Eggleton,et al. Evaluating the mechanical behavior of arterial tissue using digital image correlation , 2002 .
[13] Thao D Nguyen,et al. The inflation response of the posterior bovine sclera. , 2010, Acta biomaterialia.
[14] Thomas Becker,et al. Error estimations of 3D digital image correlation measurements , 2006, Speckle: International Conference on Speckle Metrology.
[15] S. Xia,et al. Diffraction Assisted Image Correlation: A Novel Method for Measuring Three-Dimensional Deformation using Two-Dimensional Digital Image Correlation , 2013 .
[16] J. L. Martin,et al. Characterisation of TiN thin films using the bulge test and the nanoindentation technique , 1997 .
[17] H. Quigley,et al. The in vitro inflation response of mouse sclera. , 2010, Experimental eye research.
[18] Y. Wang,et al. Impact of lens distortions on strain measurements obtained with 2D digital image correlation , 2013 .
[19] Wei Sun,et al. Determination of three-dimensional displacement using two-dimensional digital image correlation. , 2008, Applied optics.
[20] D. Arola,et al. Applications of digital image correlation to biological tissues. , 2004, Journal of biomedical optics.
[21] Thao D Nguyen,et al. Full-field bulge test for planar anisotropic tissues: part I--experimental methods applied to human skin tissue. , 2013, Acta biomaterialia.
[22] Dimitri Debruyne,et al. Full-field optical deformation measurement in biomechanics: digital speckle pattern interferometry and 3D digital image correlation applied to bird beaks. , 2012, Journal of the mechanical behavior of biomedical materials.
[23] Anand Asundi,et al. Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review , 2009 .
[24] Jian Lu,et al. Error evaluation technique for three-dimensional digital image correlation. , 2011, Applied optics.
[25] Roger Y. Tsai,et al. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..
[26] Bing Pan,et al. High-Accuracy 2D Digital Image Correlation Measurements with Bilateral Telecentric Lenses: Error Analysis and Experimental Verification , 2013 .
[27] Yu Fu,et al. Digital image correlation for whole field out-of-plane displacement measurement using a single camera , 2005 .
[28] H. Quigley,et al. The effects of glycosaminoglycan degradation on the mechanical behavior of the posterior porcine sclera. , 2015, Acta biomaterialia.
[29] C. Menq,et al. Cancelling bias induced by correlation coefficient interpolation for sub-pixel image registration , 2013 .
[30] Bertrand Wattrisse,et al. Kinematic manifestations of localisation phenomena in steels by digital image correlation , 2001 .
[31] G. Ateshian,et al. An automated approach for direct measurement of two-dimensional strain distributions within articular cartilage under unconfined compression. , 2002, Journal of biomechanical engineering.
[32] Stephen L. Alexander,et al. Minimal preconditioning effects observed for inflation tests of planar tissues. , 2013, Journal of biomechanical engineering.
[33] Dwayne Arola,et al. Displacement/strain measurements using an optical microscope and digital image correlation , 2006 .
[34] M. Bottlang,et al. Scleral biomechanics in the aging monkey eye. , 2009, Investigative ophthalmology & visual science.
[35] A. Waas,et al. Three-dimensional digital image correlation technique using single high-speed camera for measuring large out-of-plane displacements at high framing rates. , 2010, Applied optics.
[36] S M Lessner,et al. Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation. , 2008, Journal of biomedical materials research. Part A.
[37] Joost J. Vlassak,et al. A new bulge test technique for the determination of Young’s modulus and Poisson’s ratio of thin films , 1992 .
[38] Thao D Nguyen,et al. Biomechanics of the human posterior sclera: age- and glaucoma-related changes measured using inflation testing. , 2012, Investigative ophthalmology & visual science.
[39] Michael A. Sutton,et al. Error Assessment in Stereo-based Deformation Measurements , 2011 .