Phasor-based assessment for harmonic sources in distribution networks
暂无分享,去创建一个
Virgilio Centeno | Danling Cheng | Ahmet Onen | Robert P. Broadwater | Reza Arghandeh | Jaesung Jung | R. Arghandeh | R. Broadwater | V. Centeno | A. Onen | Jaesung Jung | Danling Cheng
[1] P.J.M. Heskes,et al. Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.
[2] Joshua Hambrick,et al. Advantages of Integrated System Model-Based Control for Electrical Distribution System Automation , 2011 .
[3] Biao Huang,et al. Determining the Harmonic Impacts of Multiple Harmonic-Producing Loads , 2011, IEEE Transactions on Power Delivery.
[4] Paul S. Moses,et al. Impact of balanced and unbalanced direct current bias on harmonic distortion generated by asymmetric three-phase three-leg transformers , 2010 .
[5] S.M. Halpin,et al. Comparison of IEEE and IEC harmonic standards , 2005, IEEE Power Engineering Society General Meeting, 2005.
[6] M. Dilek,et al. Simultaneous Phase Balancing at Substations and Switches with Time-Varying Load Patterns , 2001, IEEE Power Engineering Review.
[7] Azah Mohamed,et al. A new method for determining multiple harmonic source locations in a power distribution system , 2010, 2010 IEEE International Conference on Power and Energy.
[8] Swapan Kumar Goswami,et al. Reduction of voltage harmonics using optimisation-based combined approach , 2010 .
[9] Jang-Mok Kim,et al. Photovoltaic power interface circuit incorporated with a buck-boost converter and a full-bridge inverter , 2005 .
[10] Frede Blaabjerg,et al. Synthesis of Variable Harmonic Impedance in Inverter-Interfaced Distributed Generation Unit for Harmonic Damping Throughout a Distribution Network , 2012, IEEE Transactions on Industry Applications.
[11] Hossein Iman-Eini,et al. An optimal selective harmonic mitigation technique for high power converters , 2013 .
[12] Danling Cheng,et al. A graph trace based reliability analysis of electric power systems with time-varying loads and dependent failures , 2009 .
[13] William Kersting,et al. Distribution System Modeling and Analysis , 2001, Electric Power Generation, Transmission, and Distribution: The Electric Power Engineering Handbook.
[14] J.V. Milanovic,et al. Planning Approaches for the Strategic Placement of Passive Harmonic Filters in Radial Distribution Networks , 2007, IEEE Transactions on Power Delivery.
[15] R. P. Broadwater,et al. Configurable, Hierarchical, Model-Based Control of Electrical Distribution Circuits , 2011, IEEE Transactions on Power Systems.
[16] Virgilio Centeno,et al. Harmonic Impact Study for Distributed Energy Resources Integrated Into Power Distribution Networks , 2013 .
[17] Azah Mohamed,et al. An enhanced method for contribution assessment of utility and customer harmonic distortions in radial and weakly meshed distribution systems , 2012 .
[18] Leopoldo García Franquelo,et al. Selective Harmonic Mitigation Technique for High-Power Converters , 2010, IEEE Transactions on Industrial Electronics.
[19] Francisco de Leon,et al. A Robust Multiphase Power Flow for General Distribution Networks , 2010, IEEE Transactions on Power Systems.
[20] W. Freitas,et al. Assessing the Collective Harmonic Impact of Modern Residential Loads—Part I: Methodology , 2012, IEEE Transactions on Power Delivery.
[21] Ahmet Onen,et al. Harmonic interactions of multiple distributed energy resources in power distribution networks , 2013 .
[22] Roberto Langella,et al. Unbalance Definition for Electrical Power Systems in the Presence of Harmonics and Interharmonics , 2012, IEEE Transactions on Instrumentation and Measurement.
[23] A. Mansoor. Lower order harmonic cancellation: impact of low-voltage network topology , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).
[24] Francisco C. De La Rosa. Harmonics and Power Systems , 2006 .
[25] D.P. Labridis,et al. Harmonic impact of small photovoltaic systems connected to the LV distribution network , 2008, 2008 5th International Conference on the European Electricity Market.
[26] Arindam Ghosh,et al. The use of instantaneous symmetrical components for balancing a delta connected load and power factor correction , 2000 .
[27] L. Cividino,et al. Power factor, harmonic distortion; causes, effects and considerations , 1992, [Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92.
[28] M. Dilek,et al. Computing distribution system fault currents and voltages via numerically computed Thevenin equivalents and sensitivity matrices , 2004, IEEE PES Power Systems Conference and Exposition, 2004..
[29] Jorge L. Duarte,et al. Harmonic reduction as ancillary service by inverters for distributed energy resources (der) in electricity distribution networks , 2007 .
[30] Jeremy Woyak,et al. Smart Model Based Coordinated Control Based on Feeder Losses, Energy Consumption, and Voltage Violations , 2013 .
[31] M. A. S. Masoum,et al. Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings, and Hysteresis , 2012, IEEE Transactions on Energy Conversion.
[32] Fei Wang,et al. Modeling and Analysis of Grid Harmonic Distortion Impact of Aggregated DG Inverters , 2011, IEEE Transactions on Power Electronics.