Phasor-based assessment for harmonic sources in distribution networks

a b s t r a c t Phasor-based interdependencies of multiple harmonic sources, especially Distributed Energy Resources, on distribution networks are analyzed in this paper. A new index, Phasor Harmonic Index (IPH), is pro- posed by the authors. IPH considers both harmonic source magnitude and phase angle for different harmonic orders. Other commonly used harmonic indices are based solely on magnitude of waveforms. A very detailed model of a distribution network is used in the harmonic assessment. With the help of the detailed distribution network model, the phase couplings and the phase balancing impacts on harmonic propagation between three phases are investigated. Moreover, effects of harmonic source phase angle deviations are analyzed at both the customer side and the substation side. This paper investigates the importance of phase angles in harmonic assessment and how distribution network characteristics can be analyzed appropriately with phasor-based harmonic studies. In addition to device level harmonics, system level harmonic propagation need to be considered.

[1]  P.J.M. Heskes,et al.  Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.

[2]  Joshua Hambrick,et al.  Advantages of Integrated System Model-Based Control for Electrical Distribution System Automation , 2011 .

[3]  Biao Huang,et al.  Determining the Harmonic Impacts of Multiple Harmonic-Producing Loads , 2011, IEEE Transactions on Power Delivery.

[4]  Paul S. Moses,et al.  Impact of balanced and unbalanced direct current bias on harmonic distortion generated by asymmetric three-phase three-leg transformers , 2010 .

[5]  S.M. Halpin,et al.  Comparison of IEEE and IEC harmonic standards , 2005, IEEE Power Engineering Society General Meeting, 2005.

[6]  M. Dilek,et al.  Simultaneous Phase Balancing at Substations and Switches with Time-Varying Load Patterns , 2001, IEEE Power Engineering Review.

[7]  Azah Mohamed,et al.  A new method for determining multiple harmonic source locations in a power distribution system , 2010, 2010 IEEE International Conference on Power and Energy.

[8]  Swapan Kumar Goswami,et al.  Reduction of voltage harmonics using optimisation-based combined approach , 2010 .

[9]  Jang-Mok Kim,et al.  Photovoltaic power interface circuit incorporated with a buck-boost converter and a full-bridge inverter , 2005 .

[10]  Frede Blaabjerg,et al.  Synthesis of Variable Harmonic Impedance in Inverter-Interfaced Distributed Generation Unit for Harmonic Damping Throughout a Distribution Network , 2012, IEEE Transactions on Industry Applications.

[11]  Hossein Iman-Eini,et al.  An optimal selective harmonic mitigation technique for high power converters , 2013 .

[12]  Danling Cheng,et al.  A graph trace based reliability analysis of electric power systems with time-varying loads and dependent failures , 2009 .

[13]  William Kersting,et al.  Distribution System Modeling and Analysis , 2001, Electric Power Generation, Transmission, and Distribution: The Electric Power Engineering Handbook.

[14]  J.V. Milanovic,et al.  Planning Approaches for the Strategic Placement of Passive Harmonic Filters in Radial Distribution Networks , 2007, IEEE Transactions on Power Delivery.

[15]  R. P. Broadwater,et al.  Configurable, Hierarchical, Model-Based Control of Electrical Distribution Circuits , 2011, IEEE Transactions on Power Systems.

[16]  Virgilio Centeno,et al.  Harmonic Impact Study for Distributed Energy Resources Integrated Into Power Distribution Networks , 2013 .

[17]  Azah Mohamed,et al.  An enhanced method for contribution assessment of utility and customer harmonic distortions in radial and weakly meshed distribution systems , 2012 .

[18]  Leopoldo García Franquelo,et al.  Selective Harmonic Mitigation Technique for High-Power Converters , 2010, IEEE Transactions on Industrial Electronics.

[19]  Francisco de Leon,et al.  A Robust Multiphase Power Flow for General Distribution Networks , 2010, IEEE Transactions on Power Systems.

[20]  W. Freitas,et al.  Assessing the Collective Harmonic Impact of Modern Residential Loads—Part I: Methodology , 2012, IEEE Transactions on Power Delivery.

[21]  Ahmet Onen,et al.  Harmonic interactions of multiple distributed energy resources in power distribution networks , 2013 .

[22]  Roberto Langella,et al.  Unbalance Definition for Electrical Power Systems in the Presence of Harmonics and Interharmonics , 2012, IEEE Transactions on Instrumentation and Measurement.

[23]  A. Mansoor Lower order harmonic cancellation: impact of low-voltage network topology , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).

[24]  Francisco C. De La Rosa Harmonics and Power Systems , 2006 .

[25]  D.P. Labridis,et al.  Harmonic impact of small photovoltaic systems connected to the LV distribution network , 2008, 2008 5th International Conference on the European Electricity Market.

[26]  Arindam Ghosh,et al.  The use of instantaneous symmetrical components for balancing a delta connected load and power factor correction , 2000 .

[27]  L. Cividino,et al.  Power factor, harmonic distortion; causes, effects and considerations , 1992, [Proceedings] Fourteenth International Telecommunications Energy Conference - INTELEC '92.

[28]  M. Dilek,et al.  Computing distribution system fault currents and voltages via numerically computed Thevenin equivalents and sensitivity matrices , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[29]  Jorge L. Duarte,et al.  Harmonic reduction as ancillary service by inverters for distributed energy resources (der) in electricity distribution networks , 2007 .

[30]  Jeremy Woyak,et al.  Smart Model Based Coordinated Control Based on Feeder Losses, Energy Consumption, and Voltage Violations , 2013 .

[31]  M. A. S. Masoum,et al.  Three-Phase Asymmetric Transformer Aging Considering Voltage-Current Harmonic Interactions, Unbalanced Nonlinear Loading, Magnetic Couplings, and Hysteresis , 2012, IEEE Transactions on Energy Conversion.

[32]  Fei Wang,et al.  Modeling and Analysis of Grid Harmonic Distortion Impact of Aggregated DG Inverters , 2011, IEEE Transactions on Power Electronics.