* Murine Model of Progressive Orthopedic Wear Particle-Induced Chronic Inflammation and Osteolysis.

Periprosthetic osteolysis and subsequent aseptic loosening of total joint replacements are driven by byproducts of wear released from the implant. Wear particles cause macrophage-mediated inflammation that culminates with periprosthetic bone loss. Most current animal models of particle-induced osteolysis are based on the acute inflammatory reaction induced by wear debris, which is distinct from the slowly progressive clinical scenario. To address this limitation, we previously developed a murine model of periprosthetic osteolysis that is based on slow continuous delivery of wear particles into the murine distal femur over a period of 4 weeks. The particle delivery was accomplished by using subcutaneously implanted osmotic pumps and tubing, and a hollow titanium rod press-fit into the distal femur. In this study, we report a modification of our prior model in which particle delivery is extended to 8 weeks to better mimic the progressive development of periprosthetic osteolysis and allow the assessment of interventions in a setting where the chronic particle-induced osteolysis is already present at the initiation of the treatment. Compared to 4-week samples, extending the particle delivery to 8 weeks significantly exacerbated the local bone loss observed with μCT and the amount of both peri-implant F4/80+ macrophages and tartrate-resistant acid phosphatase-positive osteoclasts detected with immunohistochemical and histochemical staining. Furthermore, systemic recruitment of reporter macrophages to peri-implant tissues observed with bioluminescence imaging continued even at the later stages of particle-induced inflammation. This modified model system could provide new insights into the mechanisms of chronic inflammatory bone loss and be particularly useful in assessing the efficacy of treatments in a setting that resembles the clinical scenario of developing periprosthetic osteolysis more closely than currently existing model systems.

[1]  J. Jacobs,et al.  TLR4 (not TLR2) dominate cognate TLR activity associated with CoCrMo implant particles , 2017, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[2]  S. Goodman,et al.  Mesenchymal stem cells in the aseptic loosening of total joint replacements. , 2017, Journal of biomedical materials research. Part A.

[3]  S. Goodman,et al.  Correlations between macrophage polarizing cytokines, inflammatory mediators, osteoclast activity, and toll-like receptors in tissues around aseptically loosened hip implants. , 2017, Journal of biomedical materials research. Part A.

[4]  Fan Yang,et al.  The effect of local IL-4 delivery or CCL2 blockade on implant fixation and bone structural properties in a mouse model of wear particle induced osteolysis. , 2016, Journal of biomedical materials research. Part A.

[5]  Fan Yang,et al.  Local delivery of mutant CCL2 protein‐reduced orthopaedic implant wear particle‐induced osteolysis and inflammation in vivo , 2016, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[6]  S. Goodman,et al.  NF-κB decoy oligodeoxynucleotide inhibits wear particle-induced inflammation in a murine calvarial model. , 2015, Journal of biomedical materials research. Part A.

[7]  Y. Konttinen,et al.  Establishment of Green Fluorescent Protein and Firefly Luciferase Expressing Mouse Primary Macrophages for In Vivo Bioluminescence Imaging , 2015, PloS one.

[8]  V. Escriou,et al.  Inhibition of osteolysis and increase of bone formation after local administration of siRNA-targeting RANK in a polyethylene particle-induced osteolysis model. , 2015, Acta biomaterialia.

[9]  S. Goodman,et al.  Interaction of Materials and Biology in Total Joint Replacement - Successes, Challenges and Future Directions. , 2014, Journal of materials chemistry. B.

[10]  Y. Konttinen,et al.  Characterization of macrophage polarizing cytokines in the aseptic loosening of total hip replacements , 2014, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  J. Jacobs,et al.  The Pathology of Orthopedic Implant Failure Is Mediated by Innate Immune System Cytokines , 2014, Mediators of inflammation.

[12]  Milan Raska,et al.  Macrophages-Key cells in the response to wear debris from joint replacements. , 2013, Journal of biomedical materials research. Part A.

[13]  S. Goodman,et al.  Revision joint replacement, wear particles, and macrophage polarization. , 2012, Acta biomaterialia.

[14]  S. Goodman,et al.  Selective inhibition of the MCP‐1‐CCR2 ligand‐receptor axis decreases systemic trafficking of macrophages in the presence of UHMWPE particles , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[15]  S. Goodman,et al.  Continuous Infusion of UHMWPE Particles Induces Increased Bone Macrophages and Osteolysis , 2011, Clinical orthopaedics and related research.

[16]  Victor M. Goldberg,et al.  Bacterial Pathogen-associated Molecular Patterns Stimulate Biological Activity of Orthopaedic Wear Particles by Activating Cognate Toll-like Receptors* , 2010, The Journal of Biological Chemistry.

[17]  I. Stockley,et al.  Long-term outcome of a cementless, hemispherical, press-fit acetabular component: survivorship analysis and dose-response relationship to linear polyethylene wear. , 2010, The Journal of bone and joint surgery. British volume.

[18]  L. Sedel,et al.  Decrease in particle‐induced osteolysis in ovariectomized mice , 2010, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  D. Lindsey,et al.  An in vivo murine model of continuous intramedullary infusion of polyethylene particles. , 2008, Biomaterials.

[20]  T. Sculco,et al.  Expression profiling reveals alternative macrophage activation and impaired osteogenesis in periprosthetic osteolysis , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[21]  J. Balthasar,et al.  Comparison of the effects of antibody-coated liposomes, IVIG, and anti-RBC immunotherapy in a murine model of passive chronic immune thrombocytopenia. , 2007, Blood.

[22]  Jocelyn M. Cottrell,et al.  Stair ascent kinematics affect UHMWPE wear and damage in total knee replacements. , 2006, Journal of biomedical materials research. Part B, Applied biomaterials.

[23]  G. Saxler,,et al.  Promotion of bone formation by simvastatin in polyethylene particle-induced osteolysis. , 2005, Biomaterials.

[24]  Richard Eastell,et al.  Polyethylene wear rate and osteolysis: Critical threshold versus continuous dose‐response relationship , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[25]  John Fisher,et al.  The role of macrophages in osteolysis of total joint replacement. , 2005, Biomaterials.

[26]  Scott R. Presnell,et al.  Interleukin 31, a cytokine produced by activated T cells, induces dermatitis in mice , 2004, Nature Immunology.

[27]  E. Schwarz,et al.  Use of volumetric computerized tomography as a primary outcome measure to evaluate drug efficacy in the prevention of peri‐prosthetic osteolysis: A 1‐year clinical pilot of etanercept vs. placebo , 2003, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[28]  Allison L. Sieving,et al.  Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene (UHMWPE) wear debris that provoke inflammation in a murine model of inflammation. , 2003, Journal of biomedical materials research. Part A.

[29]  Allison L. Sieving,et al.  Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation. , 2002, Biomaterials.

[30]  E. Schwarz,et al.  Viral interleukin-10 gene inhibition of inflammation, osteoclastogenesis, and bone resorption in response to titanium particles. , 2002, Arthritis and rheumatism.

[31]  P. Millett,et al.  Effects of Alendronate on Particle-Induced Osteolysis in a Rat Model , 2002, The Journal of bone and joint surgery. American volume.

[32]  Allison L. Sieving,et al.  Inflammatory responses to orthopaedic biomaterials in the murine air pouch. , 2002, Biomaterials.

[33]  V. Goldberg,et al.  Rapid repair of titanium particle‐induced osteolysis is dramatically reduced in aged mice , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[34]  C. Engh,et al.  Characterization of Long-Term Femoral-Head-Penetration Rates: Association with and Prediction of Osteolysis* , 2000, The Journal of bone and joint surgery. American volume.

[35]  J. Fisher,et al.  Biological reactions to wear debris in total joint replacement , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[36]  S. Teitelbaum,et al.  Tumor necrosis factor-alpha mediates orthopedic implant osteolysis. , 1999, The American journal of pathology.

[37]  H. Rubash,et al.  The John Charnley Award. Inhibition of wear debris mediated osteolysis in a canine total hip arthroplasty model. , 1997, Clinical orthopaedics and related research.

[38]  P. Campbell,et al.  Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues. , 1995, Journal of biomedical materials research.

[39]  T. Bauer,et al.  Isolation and characterization of debris in membranes around total joint prostheses. , 1994, The Journal of bone and joint surgery. American volume.

[40]  J O Galante,et al.  Composition and morphology of wear debris in failed uncemented total hip replacement. , 1994, The Journal of bone and joint surgery. British volume.