Accuracy requirements in radiotherapy treatment planning.

Radiation therapy attempts to deliver ionizing radiation to the tumour and can improve the survival chances and/or quality of life of patients. There are chances of errors and uncertainties in the entire process of radiotherapy that may affect the accuracy and precision of treatment management and decrease degree of conformation. All expected inaccuracies, like radiation dose determination, volume calculation, complete evaluation of the full extent of the tumour, biological behaviour of specific tumour types, organ motion during radiotherapy, imaging, biological/molecular uncertainties, sub-clinical diseases, microscopic spread of the disease, uncertainty in normal tissue responses and radiation morbidity need sound appreciation. Conformity can be increased by reduction of such inaccuracies. With the yearly increase in computing speed and advancement in other technologies the future will provide the opportunity to optimize a greater number of variables and reduce the errors in the treatment planning process. In multi-disciplined task of radiotherapy, efforts are needed to overcome the errors and uncertainty, not only by the physicists but also by radiologists, pathologists and oncologists to reduce molecular and biological uncertainties. The radiation therapy physics is advancing towards an optimal goal that is definitely to improve accuracy where necessary and to reduce uncertainty where possible.

[1]  J A Purdy,et al.  Advances in 3-dimensional radiation treatment planning systems: room-view display with real time interactivity. , 1993, International journal of radiation oncology, biology, physics.

[2]  Jiade J. Lu,et al.  The Physics of Radiation Oncology , 2013 .

[3]  B. Murray,et al.  Setup reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices. , 1999, International journal of radiation oncology, biology, physics.

[4]  A B Wolbarst,et al.  Optimization of radiation therapy, III: A method of assessing complication probabilities from dose-volume histograms. , 1987, International journal of radiation oncology, biology, physics.

[5]  Douglas L. Jones ICRU Report 50—Prescribing, Recording and Reporting Photon Beam Therapy , 1994 .

[6]  A. Nazir,et al.  An analysis of depth dose characteristics of photon in water. , 2009, Journal of Ayub Medical College, Abbottabad : JAMC.

[7]  C. Burman,et al.  Calculation of complication probability factors for non-uniform normal tissue irradiation: the effective volume method. , 1989, International journal of radiation oncology, biology, physics.

[8]  R Mohan,et al.  The role of uncertainty analysis in treatment planning. , 1991, International journal of radiation oncology, biology, physics.

[9]  D L McShan,et al.  Full integration of the beam's eye view concept into computerized treatment planning. , 1990, International journal of radiation oncology, biology, physics.

[10]  I. Lax,et al.  Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects. , 1994, Acta oncologica.

[11]  Tufve Nyholm,et al.  Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments , 2009, Radiation oncology.

[12]  G T Chen,et al.  Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy. , 1995, International journal of radiation oncology, biology, physics.

[13]  C. Pelizzari,et al.  The use of beam's eye view volumetrics in the selection of non-coplanar radiation portals. , 1992, International journal of radiation oncology, biology, physics.

[14]  B. Michaelis,et al.  DETECTION OF TUMOR IN DIGITAL IMAGES OF THE BRAIN , 2001 .

[15]  J Wong,et al.  Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[16]  Harold O. Wyckoff,et al.  International Commission ON Radiation Units and Measurements (ICRU). , 1974, The American journal of roentgenology, radium therapy, and nuclear medicine.

[17]  B. Heijmen,et al.  Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning. , 2001, International journal of radiation oncology, biology, physics.

[18]  J. Knisely Practical Radiotherapy Planning , 1992 .

[19]  R Mohan,et al.  A model for computer-controlled delivery of 3-D conformal treatments. , 1992, Medical physics.

[21]  Yukio Uchiyama,et al.  Assessment of spatial uncertainties in the radiotherapy process with the Novalis system. , 2009, International journal of radiation oncology, biology, physics.

[22]  M. Goitein,et al.  Multi-dimensional treatment planning: II. Beam's eye-view, back projection, and projection through CT sections. , 1983, International journal of radiation oncology, biology, physics.

[23]  M. Moerland,et al.  A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate. , 1997, International journal of radiation oncology, biology, physics.

[24]  J. Sham,et al.  Target dose conformity in 3-dimensional conformal radiotherapy and intensity modulated radiotherapy. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  Michael K Fix,et al.  Monte Carlo dose calculation on deforming anatomy. , 2011, Zeitschrift fur medizinische Physik.

[26]  Treatment planning for protocol-based radiation therapy. , 1990, International journal of radiation oncology, biology, physics.

[27]  G T Chen,et al.  Beams eye view-based photon radiotherapy I. , 1991, International journal of radiation oncology, biology, physics.

[28]  P. Teo,et al.  Intensity-modulated radiotherapy in nasopharyngeal carcinoma: dosimetric advantage over conventional plans and feasibility of dose escalation. , 2003, International journal of radiation oncology, biology, physics.

[29]  Gunilla C. Bentel,et al.  Treatment Planning and Dose Calculation in Radiation Oncology , 1982 .

[30]  G J Kutcher,et al.  The effect of setup uncertainties on the treatment of nasopharynx cancer. , 1993, International journal of radiation oncology, biology, physics.

[31]  A. Todd-Pokropek,et al.  Comparison of pencil beam and collapsed cone algorithms, in radiotherapy treatment planning for 6 and 10 MV photon. , 2010, Journal of Ayub Medical College, Abbottabad : JAMC.

[32]  S Senan,et al.  An analysis of anatomic landmark mobility and setup deviations in radiotherapy for lung cancer. , 1999, International journal of radiation oncology, biology, physics.

[33]  S. Buzdar,et al.  Verification of computerized treatment planning for HDR 192Ir brachytherapy for gynaecological cancer. , 2009, JPMA. The Journal of the Pakistan Medical Association.

[34]  G T Chen,et al.  Beam's eye view based prostate treatment planning: is it useful? , 1990, International journal of radiation oncology, biology, physics.

[35]  S. Webb,et al.  A quantitative treatment planning study evaluating the potential of dose escalation in conformal radiotherapy of the oesophagus. , 2000, Radiotherapy and Oncology.

[36]  M Goitein,et al.  Implementation of a model for estimating tumor control probability for an inhomogeneously irradiated tumor. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[37]  D. Dearnaley,et al.  Target volume definition in conformal radiotherapy for prostate cancer: quality assurance in the MRC RT-01 trial. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[38]  R. Mohan,et al.  Compensation in three-dimensional non-coplanar treatment planning. , 1991, International journal of radiation oncology, biology, physics.

[39]  M. Hiraoka,et al.  Comparisons of the impact of systematic uncertainties in patient setup and prostate motion on doses to the target among different plans for definitive external-beam radiotherapy for prostate cancer , 2008, International Journal of Clinical Oncology.

[40]  M. Eble,et al.  Image-guided radiotherapy for prostate cancer , 2008, Strahlentherapie und Onkologie.

[41]  P. Wootton,et al.  Dose Specification for Reporting External Beam Therapy with Photons and Electrons , 1979 .

[42]  Hiroki Shirato,et al.  Evaluation of the effectiveness of the stereotactic body frame in reducing respiratory intrafractional organ motion using the real-time tumor-tracking radiotherapy system. , 2010, International journal of radiation oncology, biology, physics.

[43]  J. Cox,et al.  Weekly localization films and detection of field placement errors. , 1978, International journal of radiation oncology, biology, physics.

[44]  Andrew Jackson,et al.  Dosimetric effect of respiratory motion in external beam radiotherapy of the lung. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.