What approach to brain partial volume correction is best for PET/MRI?

Many partial volume correction approaches make use of anatomical information, readily available in PET/MRI systems but it is not clear what approach is best. Seven novel approaches to partial volume correction were evaluated, including several post-reconstruction methods and several reconstruction methods that incorporate anatomical information. These were compared with an MRI-independent approach (reblurred van Cittert ) and uncorrected data. Monte Carlo PET data were generated for activity distributions representing both 18F FDG and amyloid tracer uptake. Post-reconstruction methods provided the best recovery with ideal segmentation but were particularly sensitive to mis-registration. Alternative approaches performed better in maintaining lesion contrast (unseen in MRI) with good noise control. These were also relatively insensitive to mis-registration errors. The choice of method will depend on the specific application and reliability of segmentation and registration algorithms.

[1]  S. Pedemonte,et al.  Class conditional entropic prior for MRI enhanced SPECT reconstruction , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[2]  M. Modat,et al.  The importance of appropriate partial volume correction for PET quantification in Alzheimer’s disease , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[3]  Anthonin Reilhac,et al.  Evaluation of Three MRI-Based Anatomical Priors for Quantitative PET Brain Imaging , 2012, IEEE Transactions on Medical Imaging.

[4]  I. Buvat,et al.  A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology , 2012, Physics in medicine and biology.

[5]  Anthonin Reilhac,et al.  Deconvolution-based partial volume correction in Raclopride-PET and Monte Carlo comparison to MR-based method , 2008, NeuroImage.

[6]  Alan C. Evans,et al.  PET-SORTEO: a Monte Carlo-based Simulator with high count rate capabilities , 2004, IEEE Transactions on Nuclear Science.

[7]  A. Evans,et al.  Correction for partial volume effects in PET: principle and validation. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[9]  Arthur W. Toga,et al.  Investigation of partial volume correction methods for brain FDG PET studies , 1996 .

[10]  Sébastien Ourselin,et al.  An anatomically driven anisotropic diffusion filtering method for 3D SPECT reconstruction , 2012, Physics in medicine and biology.

[11]  B. Hutton,et al.  Partial volume correction in SPECT reconstruction with OSEM , 2011 .

[12]  Sébastien Ourselin,et al.  Markov random field and Gaussian mixture for segmented MRI-based partial volume correction in PET , 2012, Physics in medicine and biology.