Selective Nerve Cuff Stimulation Strategies for Prolonging Muscle Output

Neural stimulation systems are often limited by rapid muscle fatigue. Selective nerve cuff electrodes can target independent yet synergistic motor unit pools (MUPs), which can be used in duty-cycle reducing stimulation paradigms to prolong joint moment output. Objective: This study investigates waveform parameters within moment-prolonging paradigms and determines strategies for their optimal implementation. Methods: Composite flat-interface nerve cuff electrodes (C-FINEs) were chronically implanted on feline proximal sciatic nerves. Cyclic stimulation tests determined effects of stimulation period and duty cycle in different MUP types. Ideal parameters were then used in duty-cycle reducing carousel stimulation. Time to 50% reduction in moment (T50), moment overshoot, and moment ripple were determined for constant, open-loop carousel, and moment feedback-controlled closed-loop carousel stimulation. Results: A stimulation period of 1 s best maintained joint moment for all MUPs. Low (25%) duty cycles consistently improved joint moment maintenance, though allowable duty cycle varied among MUPs by gross muscle and fiber type. Both open- and closed-loop carousel stimulation significantly increased T50 over constant stimulation. Closed-loop carousel significantly decreased moment overshoot over the other conditions, and significantly decreased moment ripple compared with open-loop stimulation. Conclusion: Selectivity-enabled carousel stimulation prolongs joint moment over conventional constant stimulation. Appropriate waveform parameters can be quickly determined for individual MUPs and stimulation can be controlled for additional performance improvements with this paradigm. Significance: Providing prolonged, stable joint moment and muscle output to recipients of motor neuroprostheses will improve clinical outcomes, increase independence, and positively impact quality of life.

[1]  K. Hainaut,et al.  Electrical and mechanical failures during sustained and intermittent contractions in humans. , 1985, Journal of applied physiology.

[2]  J. Mortimer,et al.  Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[3]  T. Bajd,et al.  Multichannel electrical stimulation for correction of hemiplegic gait. Methodology and preliminary results. , 1978, Scandinavian journal of rehabilitation medicine.

[4]  E. Bichler,et al.  The time course of the last contractions during incompletely fused tetani of motor units in rat skeletal muscle. , 2002, Acta neurobiologiae experimentalis.

[5]  Ronald J Triolo,et al.  Optimization of selective stimulation parameters for multi-contact electrodes , 2013, Journal of NeuroEngineering and Rehabilitation.

[6]  Jesse C. Dean,et al.  Motor unit recruitment during neuromuscular electrical stimulation: a critical appraisal , 2011, European Journal of Applied Physiology.

[7]  D. Levine,et al.  Physiological types and histochemical profiles in motor units of the cat gastrocnemius , 1973, The Journal of physiology.

[8]  W. D. Letbetter,et al.  A histochemical analysis of identified compartments of cat lateral gastrocnemius muscle , 1982, The Anatomical record.

[9]  K. Yoshida,et al.  Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes , 1993, IEEE Transactions on Biomedical Engineering.

[10]  J. Mortimer,et al.  A method to effect physiological recruitment order in electrically activated muscle , 1991, IEEE Transactions on Biomedical Engineering.

[11]  G. Dudley,et al.  Effects of electrical stimulation parameters on fatigue in skeletal muscle. , 2009, The Journal of orthopaedic and sports physical therapy.

[12]  G. Somjen,et al.  FUNCTIONAL SIGNIFICANCE OF CELL SIZE IN SPINAL MOTONEURONS. , 1965, Journal of neurophysiology.

[13]  J P Paul,et al.  Reduction of muscle fatigue in man by cyclical stimulation. , 1988, Journal of biomedical engineering.

[14]  Warren E. Dixon,et al.  Comparing the Induced Muscle Fatigue Between Asynchronous and Synchronous Electrical Stimulation in Able-Bodied and Spinal Cord Injured Populations , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  R J Triolo,et al.  The design of and chronic tissue response to a composite nerve electrode with patterned stiffness , 2017, Journal of neural engineering.

[16]  J. Mizrahi,et al.  A model of fatigue and recovery in paraplegic's quadriceps muscle subjected to intermittent FES. , 1996, Journal of biomechanical engineering.

[17]  W. Grill,et al.  Quantification of recruitment properties of multiple contact cuff electrodes. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[18]  J. M. Hausdorff,et al.  Open-loop position control of the knee joint using electrical stimulation of the quadriceps and hamstrings , 2006, Medical and Biological Engineering and Computing.

[19]  R. Triolo,et al.  Selective activation of the human tibial and common peroneal nerves with a flat interface nerve electrode , 2013, Journal of neural engineering.

[20]  Daniel K. Leventhal,et al.  Subfascicle Stimulation Selectivity with the Flat Interface Nerve Electrode , 2003, Annals of Biomedical Engineering.

[21]  M. Gourdin,et al.  Impact of ischemia on cellular metabolism , 2013 .

[22]  John M Looft,et al.  A three-compartment muscle fatigue model accurately predicts joint-specific maximum endurance times for sustained isometric tasks. , 2012, Journal of biomechanics.

[23]  R. Normann,et al.  Interleaved, multisite electrical stimulation of cat sciatic nerve produces fatigue-resistant, ripple-free motor responses , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[24]  D. Durand,et al.  Functionally selective peripheral nerve stimulation with a flat interface nerve electrode , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[25]  Michael E. Miller,et al.  Standing After Spinal Cord Injury With Four-Contact Nerve-Cuff Electrodes for Quadriceps Stimulation , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[26]  Dominique M. Durand,et al.  Electrode Array for Reversing the Recruitment Order of Peripheral Nerve Stimulation: Experimental Studies , 2006, Annals of Biomedical Engineering.

[27]  D. Sale,et al.  Postactivation potentiation, fiber type, and twitch contraction time in human knee extensor muscles. , 2000, Journal of applied physiology.

[28]  The motor units of cat medial gastrocnemius: Problem of their categorisation on the basis of mechanical properties , 1975, Experimental Brain Research.

[29]  T. Nichols,et al.  Cat hindlimb muscles exert substantial torques outside the sagittal plane. , 1993, Journal of neurophysiology.

[30]  R. Kobetic,et al.  Selectivity of intramuscular stimulating electrodes in the lower limbs. , 2001, Journal of rehabilitation research and development.

[31]  M. Freeberg Anatomically-Versatile Peripheral Nerve Electrodes Preserve Nerve Health, Recruit Selectively, and Stabilize Quickly , 2018 .

[32]  R. Jacobson,et al.  Quadriceps femoris muscle resistance to fatigue using an electrically elicited fatigue test following intense endurance exercise training. , 1994, Physical therapy.

[33]  H. Milner-Brown,et al.  Quantifying human muscle strength, endurance and fatigue. , 1986, Archives of physical medicine and rehabilitation.

[34]  J. Mortimer,et al.  Selective activation of small motor axons by quasitrapezoidal current pulses , 1991, IEEE Transactions on Biomedical Engineering.

[35]  Robert M. Reinking,et al.  Tetrapartite classification of motor units of cat tibialis posterior. , 1980, Journal of neurophysiology.

[36]  E. Henneman Relation between size of neurons and their susceptibility to discharge. , 1957, Science.

[37]  W. Durfee,et al.  Methods for estimating isometric recruitment curves of electrically stimulated muscle , 1989, IEEE Transactions on Biomedical Engineering.

[38]  R. Riener,et al.  Model-based control of FES-induced single joint movements , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[39]  D N Levine,et al.  Motor units in cat soleus muscle: physiological, histochemical and morphological characteristics , 1974, The Journal of physiology.

[40]  J S Petrofsky,et al.  Closed-loop control of movement of skeletal muscle. , 1985, Critical reviews in biomedical engineering.