Stand-Alone Wind Energy Conversion System with an Asynchronous Generator

This paper deals with a stand-alone wind energy conversion system (WECS) with an isolated asynchronous generator (IAG) and voltage and frequency (VF) control feeding three-phase four-wire loads. The reference generator currents are estimated using the instantaneous symmetrical component theory to control the voltage and frequency of an IAG system. A three-leg voltage source converter (VSC) with an isolated star/delta transformer is used as an integrated VSC. An integrated VSC with a battery energy storage system (BESS) is used to control the active and reactive powers of the WECS. The WECS is modeled and simulated in MATLAB using the Simulink and the Sim Power System (SPS) toolboxes. The proposed VF controller functions as a voltage and frequency regulator, a load leveler, a load balancer and a harmonic eliminator in the WECS. A comparison is made on the rating of the VSC with and without ac capacitors connected at the terminals of an IAG. Simulation and test results are presented to verify the control algorithm.

[1]  Andreas Wiese,et al.  Renewable Energy: technology, economics and environment , 2008 .

[2]  Hirofumi Akagi,et al.  Instantaneous power theory and applications to power conditioning , 2007 .

[3]  G. D. Marques,et al.  Four wire active power filter control circuit with phase locked loop phase angle determination , 1998 .

[4]  Adel M. Sharaf,et al.  A rule-based fuzzy logic controller for a PWM inverter in a stand alone wind energy conversion scheme , 1993 .

[5]  K. Al-Haddad,et al.  Voltage and frequency control with neutral current compensation in an isolated wind energy conversion system , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.

[6]  Ziyad M. Salameh,et al.  A mathematical model for lead-acid batteries , 1992 .

[7]  A. Ghosh,et al.  Control Strategies for Load Compensation Using Instantaneous Symmetrical Component Theory Under Different Supply Voltages , 2008, IEEE Transactions on Power Delivery.

[8]  Mohammad Tavakoli Bina,et al.  Modular Multilevel Converter Based STATCOM Topology Suitable for Medium-Voltage Unbalanced Systems , 2010 .

[9]  Mazen Abdel-Salam,et al.  Characterization and Performance Evaluation of Advanced Aircraft Electric Power Systems , 2010 .

[10]  Bhim Singh,et al.  Battery Energy Storage System Based Controller for a Wind Turbine Driven Isolated Asynchronous Generator , 2008 .

[11]  C. Nayar,et al.  Output Power Controller for a Wind-Driven Induction Generator , 1987, IEEE Transactions on Aerospace and Electronic Systems.

[12]  B. Singh,et al.  Decoupled Voltage and Frequency Controller for Isolated Asynchronous Generators Feeding Three-Phase Four-Wire Loads , 2008, IEEE Transactions on Power Delivery.