Pre-deformation Analysis on Construction of Special-shaped Thin-walled Concrete Acoustic Wind Tunnel Structure

Structural deformation of special-shaped thin-walled concrete acoustic wind tunnel under self-weight effect can not cater for requirements of high flatness and smoothness of moulding surface. Therefore pre-deformation analysis is carried out on construction of wind tunnel structure. Threshold is utilized to choose equivalent cross-section for the plane needing pre-deformation construction to do analysis. Analysis results show that design specifications of reinforced concrete is feasible for pre-deformation analysis on equivalent plane model under self-weight effect. Present construction on pre-camber wind tunnel according to deflection under self-weight effect also achieves the desired design requirements. Construction technology of arc-shaped erection template which controls mid-span pre-camber value keeps features of simple construction and high accuracy