Use of a Sonogel-Carbon electrode modified with bentonite for the determination of diazepam and chlordiazepoxide hydrochloride in tablets and their metabolite oxazepam in urine.

Sonogel-Carbon electrode (SngCE) modified with bentonite (BENT) shows an interesting alternative electrode to be used in the determination of 1,4-benzodiazepines by square wave adsorptive cathodic stripping voltammetry (SWAdCSV). Diazepam (DZ) and chlordiazepoxide hydrochloride (CPZ), were determined using SngCE modified by 5% BENT. An electrochemical study of different parameters (such as pH, buffer type, ionic strength, accumulation potential, scan rate, and accumulation time) which affect the determination of DZ and CPZ is reported. Linear concentration ranges of 0.028-0.256 μg mL(-1) DZ (r=0.9997) and 0.034-0.302 μg mL(-1) CPZ (r=0.9997) are successfully obtained after an accumulation time of 60s. The quantification and detection limits were calculated to be 14.0 and 4.0 ng mL(-1) for DZ, and 16.0 and 5.0 ng mL(-1) for CPZ, respectively. The surface of the proposed electrode was characterized by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDAX). The developed method was applied to the analysis of commercially available tablets and human urine real samples. Analysis was performed with better precision, very low detection limits, and faster than previously reported voltammetric techniques.

[1]  K. Temsamani,et al.  The Sonogel-Carbon materials as basis for development of enzyme biosensors for phenols and polyphenols monitoring: a detailed comparative study of three immobilization matrixes. , 2007, Biosensors & bioelectronics.

[2]  E. Izake,et al.  Potentiometric determination of diazepam, bromazepam and clonazepam using solid contact ion-selective electrodes , 2003 .

[3]  C. Mousty Sensors and biosensors based on clay-modified electrodes: new trends , 2004 .

[4]  J. Esteve-Romero,et al.  Direct injection micellar liquid chromatographic determination of benzodiazepines in serum. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[5]  A. Shehata,et al.  Binding of benzodiazepine drugs to bovine serum albumin: a second derivative spectrophotometric study. , 2011, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[6]  J. M. Palacios-Santander,et al.  Electrochemical analysis of endosulfan using a C18-modified carbon-paste electrode. , 2005, Chemosphere.

[7]  E. Blanco,et al.  The Sonogel-Carbon electrode as a sol-gel graphite-based electrode. , 2002, Analytical chemistry.

[8]  Allen J. Bard,et al.  Electroanalytical Chemistry: A Series of Advances , 1974 .

[9]  Shilpi Agarwal,et al.  Voltammetric techniques for the assay of pharmaceuticals--a review. , 2011, Analytical biochemistry.

[10]  M. Ghoneim,et al.  Voltammetric behavior and quantification of the sedative-hypnotic drug chlordiazepoxide in bulk form, pharmaceutical formulation and human serum at a mercury electrode. , 2004, Journal of pharmaceutical and biomedical analysis.

[11]  L. M. Cubillana-Aguilera,et al.  Modified carbon-paste electrodes as sensors for the determination of 1,4-benzodiazepines: Application to the determination of diazepam and oxazepam in biological fluids , 2006 .

[12]  K. Vytras,et al.  Carbon Paste Electrodes in Modern Electroanalysis , 2001 .

[13]  Joseph Wang,et al.  Sol–gel materials for electrochemical biosensors , 1999 .

[14]  J. L. Hidalgo-Hidalgo-de-Cisneros,et al.  Study of the Responses of a Sonogel-Carbon Electrode Towards Phenolic Compounds , 2005 .

[15]  Wei Guo,et al.  Polarographic determination of diazepam with its parallel catalytic wave in the presence of persulfate. , 2004, Journal of pharmaceutical and biomedical analysis.

[16]  A. El-Brashy,et al.  Determination of 1,4-benzodiazepines in drug dosage forms by difference spectrophotometry , 1993 .

[17]  R. Saudagar,et al.  Spectrophotometric determination of chlordiazepoxide and trifluoperazine hydrochloride from combined dosage form , 2007 .

[18]  M. Chicharro,et al.  Ephedrine Determination in Human Urine Using a Carbon Paste Electrode Modified with C18 Bonded Silica Gel , 1994 .

[19]  L. Núñez-Vergara,et al.  The chlordiazepoxide-albumin binding a bioelectrochemical approach , 1986 .

[20]  E. Lorenzo,et al.  Preconcentration and determination of bentazepam at C18-modified carbon paste electrodes , 1992 .

[21]  E. Jacobsen,et al.  Electrochemical reduction of chlordiazepoxide at mercury electrodes. , 1971, Analytica chimica acta.

[22]  E. Izake,et al.  Spectrophotometric and fluorimetric determination of diazepam, bromazepam and clonazepam in pharmaceutical and urine samples. , 2004, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[23]  P. Hernández,et al.  Cyclic voltammetry of Tifluadom at a C18-modified carbon-paste electrode , 1990 .

[24]  S. Haghgoo,et al.  QUANTITATIVE DETERMINATION OF DIAZEPAM IN PHARMACEUTICAL PREPARATION BY USING A NEW EXTRACTIVE-SPECTROPHOTOMETRIC METHOD , 2002 .

[25]  F. Nicoletti,et al.  Simultaneous analysis of diazepam and its metabolites in rat plasma and brain tissue by HPLC-UV and SPE. , 2009, Talanta.

[26]  P. F. Hernando,et al.  A rapid fluorimetric screening method for the 1,4-benzodiazepines: determination of their metabolite oxazepam in urine. , 2007 .

[27]  Correia M. dos Santos,et al.  Square-wave voltammetric techniques for determination of psychoactive 1,4-benzodiazepine drugs , 2002, Analytical and bioanalytical chemistry.

[28]  C. E. Efstathiou,et al.  Flow-injection fluorimetric determination of 1,4-benzodiazepines in pharmaceutical formulations after acid hydrolysis. , 1999, Journal of pharmaceutical and biomedical analysis.

[29]  F. Musshoff,et al.  Evaluation of two immunoassay procedures for drug testing in hair samples. , 2012, Forensic science international.

[30]  B. Gallo,et al.  Electrooxidation and determination of the 1,4-benzodiazepine loprazolam at the carbon-paste electrode , 1995 .

[31]  P. Hernández,et al.  Voltammetric determination of methyl parathion, ortho, meta and para nitrophenol with a carbon paste electrode modified with C18 , 1993 .

[32]  S. Liawruangrath,et al.  A simple flow injection spectrophotometric procedure for the determination of diazepam in pharmaceutical formulation. , 2006, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[33]  J. Miller,et al.  Statistics for Analytical Chemistry , 1993 .

[34]  P. Surmann,et al.  Voltammetric analysis using a self-renewable non-mercury electrode , 2005, Analytical and bioanalytical chemistry.

[35]  A. Fraser,et al.  Urinary screening for adinazolam and its major metabolites by the Emit d.a.u. and FPIA benzodiazepine assays with confirmation by HPLC. , 1993, Journal of analytical toxicology.

[36]  Aurélie Bugey,et al.  Rapid analysis of benzodiazepines in whole blood by high-performance liquid chromatography: use of a monolithic column. , 2004, Journal of pharmaceutical and biomedical analysis.

[37]  V. L. Silva,et al.  Cyclodextrin-based potentiometric sensors for midazolam and diazepam. , 2008, Journal of pharmaceutical and biomedical analysis.

[38]  K. Marsh,et al.  Pharmacokinetics and anticonvulsant effects of diazepam in children with severe falciparum malaria and convulsions. , 2002, British journal of clinical pharmacology.