Experimental analysis of mass transfer in adiabatic structured packing dehumidifier/regenerator with liquid desiccant

Abstract Mass-transfer characteristics of a structured packing dehumidifier/regenerator were studied using a lithium chloride solution as the desiccant. Experiments included air dehumidification and desiccant regeneration in typical operating ranges of air-conditioning applications. When the air velocity increased from 0.5 to 1.5 m/s, the overall mass-transfer coefficient in the structured packing dehumidifier and regenerator varied from 4.0 to 8.5 g/m2 s and from 2.0 to 4.5 g/m2 s, respectively. Higher solution temperature resulted in lower overall mass-transfer coefficients. Dimensionless overall mass-transfer coefficient correlations were developed for the dehumidifier and regenerator. Deviations between predicted values and experimental values were within ±20%.

[1]  Esam Elsarrag,et al.  Performance study on a structured packed liquid desiccant regenerator , 2006 .

[2]  Palanichamy Gandhidasan A simplified model for air dehumidification with liquid desiccant , 2004 .

[3]  S. K. Chaudhari,et al.  Thermodynamic Properties of Aqueous Solutions of Lithium Chloride , 2002 .

[4]  James E. Braun,et al.  An effectiveness model of liquid-desiccant system heat/mass exchangers , 1989 .

[5]  George O.G. Löf,et al.  Coefficients of Heat and Mass Transfer in a Packed Bed Suitable for Solar Regeneration of Aqueous Lithium Chloride Solutions , 1984 .

[6]  Arshad Y. Khan,et al.  Modelling and parametric analysis of heat and mass transfer performance of refrigerant cooled liquid desiccant absorbers , 1998 .

[7]  K. Y. Qu,et al.  Heat and mass transfer model of cross flow liquid desiccant air dehumidifier/regenerator , 2007 .

[8]  James R. Fair,et al.  Mass transfer in gauze packings , 1985 .

[9]  Tsair-Wang Chung,et al.  Comparison between Random and Structured Packings for Dehumidification of Air by Lithium Chloride Solutions in a Packed Column and Their Heat and Mass Transfer Correlations , 1996 .

[10]  G. Grossman,et al.  A packed bed dehumidifier/regenerator for solar air conditioning with liquid desiccants , 1980 .

[11]  † and Tsair-Wang Chung,et al.  Comparison between Spray Towers with and without Fin Coils for Air Dehumidification Using Triethylene Glycol Solutions and Development of the Mass-Transfer Correlations , 2000 .

[12]  Srinivas Garimella,et al.  A critical review of models of coupled heat and mass transfer in falling-film absorption , 2001 .

[13]  Abdulghani A. Al-Farayedhi,et al.  Evaluation of heat and mass transfer coefficients in a gauze-type structured packing air dehumidifier operating with liquid desiccant , 2002 .

[14]  John R. Howell,et al.  Numerical and experimental results for coupled heat and mass transfer between a desiccant film and air in cross-flow , 1994 .

[15]  Terry G. Lenz,et al.  Dimensionless mass-transfer correlations for packed-bed liquid-desiccant contactors , 1996 .

[16]  G. Longo,et al.  Experimental and theoretical analysis of heat and mass transfer in a packed column dehumidifier/regenerator with liquid desiccant , 2005 .

[17]  Chaobin Dang,et al.  Performance analysis of a no-frost hybrid air conditioning system with integrated liquid desiccant dehumidification , 2010 .

[18]  Andrea Gasparella,et al.  Experimental analysis on desiccant regeneration in a packed column with structured and random packing , 2009 .

[19]  A characteristic study of liquid desiccant dehumidification/regeneration processes , 2005 .